EEWORLDEEWORLDEEWORLD

Part Number

Search

GGC-V6/10

Description
Electric Fuse, Fast Blow, 0.6A, 250VAC, 35A (IR), Through Hole,
CategoryCircuit protection    Circuit protection   
File Size561KB,1 Pages
ManufacturerMersen
Websitehttps://www.mersen.com/
Environmental Compliance

With over 135 years of experience, more than 50 industrial sites and 18 R&D centers in 35 countries, Mersen Electrical Power is a global expert in power and advanced materials for high-tech industries. They offer a broad portfolio of electrical protection and control products and provide solutions for power management applications. The Mersen team works with customers around the world to design and deliver custom solutions and essential products for the commercial, industrial, renewable energy, power electronics and electric vehicle markets. Mersen's mission is to make its customers' applications safer and more reliable.

Download Datasheet Parametric View All

GGC-V6/10 Overview

Electric Fuse, Fast Blow, 0.6A, 250VAC, 35A (IR), Through Hole,

GGC-V6/10 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerMersen
Reach Compliance Codecompliant
ECCN codeEAR99
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Installation featuresTHROUGH HOLE
physical size6.35mm x 31.75mm
Rated breaking capacity35 A
Rated current0.6 A
Rated voltage250 V
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal shapePIN WIRE

GGC-V6/10 Preview

Download Datasheet
Electronic/Glass Fuses
GGC/GGC-V
Glass body
Fast-acting
1/4” x 1-1/4”
1-1/2” Axial leads optional
GGM/GGM-V
Glass body
Fast-acting
5mm x 20mm
1-1/2” Axial leads optional
1/10A through 10A, 250VAC,
UL Listed and CSA Certified
12A and 15A, 125VAC, UL Listed
and CSA Certified - 20A through 30A, 32VAC
1/16A through 3A, 250VAC,
UL Listed and CSA Certified 4A
through 8A, 125VAC, UL Listed and
CSA Certified - 10A and 15A, 250VAC, UL Recognized
Standard Fuse Ampere Ratings
Catalog
Number
GGC1/10
GGC1/8
GGC15/100
GGC175/1000
GGC3/16
GGC2/10
GGC1/4
GGC3/10
GGC3/8
GGC4/10
GGC1/2
GGC6/10
GGC3/4
GGC8/10
GGC1
GGC1-1/4
GGC1-1/2
GGC1-3/4
GGC1-6/10
GGC2
GGC2-1/4
GGC2-1/2
GGC3
GGC3-2/10
GGC4
GGC5
GGC6
GGC6-3/10
GGC7
GGC7-1/2
GGC8
GGC10
GGC12
GGC15
GGC20
GGC25
GGC30
Axial Lead
Cat. No
GGC-V1/10
GGC-V1/8
GGC-V15/100
GGC-V175/1000
GGC-V3/16
GGC-V2/10
GGC-V1/4
GGC-V3/10
GGC-V3/8
GGC-V4/10
GGC-V1/2
GGC-V6/10
GGC-V3/4
GGC-V8/10
GGC-V1
GGC-V1-1/4
GGC-V1-1/2
GGC-V1-3/4
GGC-V1-6/10
GGC-V2
GGC-V2-1/4
GGC-V2-1/2
GGC-V3
GGC-V3-2/10
GGC-V4
GGC-V5
GGC-V6
GGC-V6-3/10
GGC-V7
N/A
GGC-V8
GGC-V10
GGC-V12
GGC-V15
GGC-V20
GGC-V25
GGC-V30
Ampere
Rating
1/10A
1/8A
15/100A
175/1000A
3/16A
2/10A
1/4A
3/10A
3/8A
4/10A
1/2A
6/10A
3/4A
8/10A
1A
1-1/4A
1-1/2A
1-3/4A
1-6/10A
2A
2-1/4A
2-1/2A
3A
3-2/10A
4A
5A
6A
6-3/10A
7A
7-1/2A
8A
10A
12A
15A
20A
25A
30A
Volts
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
32V
32V
32V
I.R.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
2
2
2
2
2
2
2
2
4
4
5
5
5
Standard Fuse Ampere Ratings
Catalog
Number
GGM1/16
GGM1/10
GGM1/8
GGM2/10
GGM1/4
GGM3/10
GGM4/10
GGM1/2
GGM6/10
GGM7/10
GGM3/4
GGM8/10
GGM1
GGM1-2/10
GGM1-1/4
GGM1-1/2
GGM1-6/10
GGM2
GGM2-1/2
GGM3
GGM4
GGM5
GGM6
GGM7
GGM8
GGM10
GGM15
Axial Lead
Cat. No
GGM-V1/16
GGM-V1/10
GGM-V1/8
GGM-V2/10
GGM-V1/4
GGM-V3/10
GGM-V4/10
GGM-V1/2
GGM-V6/10
GGM-V7/10
GGM-V3/4
GGM-V8/10
GGM-V1
N/A
GGM-V1-1/4
GGM-V1-1/2
GGM-V1-6/10
GGM-V2
GGM-V2-1/2
GGM-V3
GGM-V4
GGM-V5
GGM-V6
GGM-V7
GGM-V8
GGM-V10
GGM-V15
Ampere
Rating
1/16A
1/10A
1/8A
2/10A
1/4A
3/10A
4/10A
1/2A
6/10A
7/10A
3/4A
8/10A
1A
1-2/10A
1-1/4A
1-1/2A
1-6/10A
2A
2-1/2A
3A
4A
5A
6A
7A
8A
10A
15A
Volts
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
250V
250V
I.R.
2
3
3
3
3
3
1
3
1
3
3
1
3
2
3
3
2
3
3
3
4
4
4
4
4
5
5
1.
2.
3.
4.
5.
250VAC @ 35A I.R./125VAC @ 10kA I.R.
250VAC @ 100A I.R./125VAC @ 10kA I.R.
250VAC @ 200A I.R./125VAC @ 10kA I.R.
125VAC @ 10kA I.R.
250VAC @ 100A I.R.
2.
3.
4.
5.
250VAC @ 200A I.R./125VAC @ 10kA I.R.
250VAC @ 10kA I.R.
125VAC @ 10kA I.R.
32VAC @ 1000A I.R.
C16
[Comparison of solutions] + 5V to 3.3V DC-DC power supply design based on LMZ10503 easy power module
[i=s] This post was last edited by fengye5340 on 2014-8-24 16:11 [/i] [align=left][size=4][color=Blue][b]1. Solution Introduction [/b][/color][/size][/align][align=left] As mentioned earlier, TI has a...
fengye5340 Analogue and Mixed Signal
What is TI trying to do?
[i=s]This post was last edited by dontium on 2015-1-23 11:21[/i]I received two emails one day apart. The first one told me that I could no longer apply for free samples with my corporate email address...
眼大5子 Analogue and Mixed Signal
Using FPGA to Simulate Taxi Fare Meter
Looking for a program, VHDL...
wanglinacoolmm FPGA/CPLD
GMS87C1102-1202 8-bit microcontroller.pdf
GMS87C1102-1202 8-bit microcontroller is also used to control the microprocessor GMS87C1102-1202...
rain MCU
Please tell me about the power chip in the barley box
224540 The UP10 above has CU3ZL written on the chip (I looked for it on alldatasheetcn.com and ICkey, but couldn't find it). The capacitor next to the 6-pin is 220, and the inductor is 4R7 (it should ...
lidonglei1 Power technology
A spike voltage appears when the current of a single-phase bridge phase-controlled rectifier resistor and inductive load is interrupted
[i=s]This post was last edited by Dahanchong on 2019-4-28 10:04[/i] I am a student, and when I was simulating a single-phase bridge rectifier, I encountered the phenomenon shown in the picture. How do...
大寒虫 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

About Us Customer Service Contact Information Datasheet Sitemap LatestNews

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190

Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号