2R-8*8 SERIES
DATA SHEET
GAS DISCHARGE TUBE – 2R-8*8 SERIES
FEATURES
Provide ultra-fast response to surge voltage from slow-rising surge of
100V/s to rapid-rising surge of 1KV/ s.
Stable breakdown voltage.
High insulation resistance.
Low capacitance (
1.5pF).
High holdover voltage.
Large absorbing transient current capability.
Micro-Gap Design
SIZE : 8*8mm
Storage and operational temperature:
-40 ~ +85
Meets MSL level 1, per J -STD-020
APPLICATION
Repeaters, Modems.
Telephone Interface, Line cards.
Data communication equipment.
Line test equipment.
PART NUMBER CODE
2
R
8
Electrical
Characteristics
H : 2.5KA
K : 3KA
L : 5KA
Electrode Numbers
2R : 2 Electrodes
Lead Type
L : Lead
M : SMD
Dimensions
8 : 8.0mm*8.0mm
DC
Spark-over
Voltage
Revision:09-Feb-12
www.brightking.com
2R-8*8 SERIES
DIMENSIONS
d
unit :mm
Dimension
Items
L
Spec.
D
T
T
D
Tolerance
+0.3,-0.5
+0.6,-0.1
±0.05
±0.05
Max.
+0.3,-0.5
+0.6,-0.1
±0.4
8.0
8.0
0.8
d
1.0
L
D
T
B
30.0
8.0
8.0
1.1
ELECTRICAL CHARACTERISTIC
DC
Spark-over
Voltage
Part Number
100V/s
(V)
2RH1400L-8 2RH1400M-8
2RH1600L-8 2RH1600M-8
2RH2000L-8 2RH2000M-8
2RH2500L-8 2RH2500M-8
2RH2700L-8 2RH2700M-8
2RH3000L-8 2RH3000M-8
2RH3500L-8 2RH3500M-8
2RK2700L-8 2RK2700M-8
2RK3000L-8 2RK3000M-8
2RK3500L-8 2RK3500M-8
2RK4000L-8 2RK4000M-8
2RK5000L-8 2RK5000M-8
2RK6000L-8 2RK6000M-8
2RL1000L-8 2RL1000M-8
2RL1400L-8 2RL1400M-8
2RL1600L-8 2RL1600M-8
2RL2000L-8 2RL2000M-8
2RL2500L-8 2RL2500M-8
1400±20%
1600±20%
2000±20%
2500±20%
2700±20%
3000±20%
3500±20%
2700±20%
3000±20%
3500±20%
4000±20%
5000±20%
6000±20%
1000±20%
1400±20%
1600±20%
2000±20%
2500±20%
Maximum
Impulse
Breakdown
Voltage
1000V/ s
(V)
2200
2400
2800
3600
3800
4200
5000
3800
4200
5000
5500
6400
7800
1400
2200
2400
2800
3600
Nominal
Impulse
Discharge
Current
8/20 s
10times
(KA)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
5.0
5.0
5.0
5.0
5.0
Altemating
Discharge
Current
50Hz,1sec
(A)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
5.0
5.0
5.0
5.0
5.0
Impulse
Life
10/1000 s
100A
(times)
100
100
100
100
300*
100
100
300*
300*
100
100
100
100
100
100
100
100
100
Minimum
Insulation
Resistance
Test
Voltage
DC(V)
500
500
500
500
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
1000
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Maximum
Capacitance
1MHz
Device
Marking
Code
(G )
(pF)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2RH1400-8
2RH1600-8
2RH2000-8
2RH2500-8
2RH2700-8
2RH3000-8
2RH3500-8
2RK2700-8
2RK3000-8
2RK3500-8
2RK4000-8
2RK5000-8
2RK6000-8
2RL1000-8
2RL1400-8
2RL1600-8
2RL2000-8
2RL2500-8
*Measured with an 8/20 s waveform ,100A
Revision:09-Feb-12
www.brightking.com
2R-8*8 SERIES
ELECTRICAL RATING
Item
DC Spark-over
Voltage
Maximum Impulse
Spark-over Voltage
Test Condition / Description
The voltage is measured with a low rate of rise dv / dt=100V/s
The maximum impulse breakdown voltage is measured with a rise time of
dv / dt=1000V/ s
The maximum current applying a waveform of 8/20 s that can be applied
across the terminals of the gas tube without causing the gas tube to
change more than ±25% from its initial measured DC breakdown voltage.
Dwell time between pulses is 3 minutes.
Requirement
Impulse
Discharge Current
To meet
the specified
value
Alternating
Discharge Current
Rated RMS value of AC current at 50Hz, 1 sec. 10 times. Intervals: 3min.
DC breakdown voltage may not change more than ±25% from its initial
measured DC breakdown voltage.
IR > 10
8
ohms (-20%, +30% for 70 – 90V).
The resistance of gas tube shall be measured each terminal each other
Insulation Resistance terminal.please see above spec
Capacitance
The capacitance of gas tube shall be measured each terminal to each
other terminal.
Test frequency :1MHz
Revision:09-Feb-12
www.brightking.com