Using the microcontroller MSP430F149 as the main control chip, an intelligent fire alarm system with high precision, high integration and ultra-low power consumption is designed. Using ambient temperature and smoke concentration as the basis for judging fire, the early warning of fire is completed. It is mainly composed of microcontroller control module, clock module, smoke concentration measurement module, DS18B20 temperature measurement module, sound and light alarm module, 1602 liquid crystal display module and power supply. And this system uses MSP430F149 as the lower computer to complete data collection, preprocessing and control of on-site devices, and uses the PC as the upper computer to complete various complex data processing and control of the microcontroller. The designed intelligent fire alarm system has high reliability, stability, accuracy, and high sensitivity to different types of fires, achieving the purpose of reducing the false alarm rate.
Temperature measurement module: The design uses the DS18B20 temperature sensor that supports the "one-line bus" interface, has strong anti-interference, simple external circuit, and high accuracy for real-time measurement of temperature. Among them, DS18B20 pin 2, DQ, is connected to the P2.0 pin of MSP430F149, as shown in the figure.
![Intelligent fire alarm system circuit module design drawing](http://www.eeworld.com.cn/circuit/upload/f073490e03cf734bc9b10e5aa35c5e34/cb6daef06bfa100bd06f90d27908a764.jpg)
temperature measurement
Sound and light alarm module: The buzzer emits an alarm indication sound when the microprocessor determines that there is a fire. Due to the limited I/O port driving capability of the microcontroller, a PNP transistor 2N5401 is selected to form a transistor driving circuit to drive the piezoelectric buzzer.
![Intelligent fire alarm system circuit module design drawing](http://www.eeworld.com.cn/circuit/upload/f073490e03cf734bc9b10e5aa35c5e34/bf52453e74207c357222407f62dc78bd.jpg)
Sound and light alarm module diagram
LCD display module: Display time, measured temperature, smoke concentration and other parameters on the LCD module so that we can more conveniently read the current temperature value and smoke concentration value.
![Intelligent fire alarm system circuit module design drawing](http://www.eeworld.com.cn/circuit/upload/f073490e03cf734bc9b10e5aa35c5e34/b63bd3d94f02c05a4f8481a130c9afe0.jpg)
LCD module diagram
Serial communication module: This design uses MSP430F149 as the slave computer and PC as the host computer. Data is transmitted to the PC through RS-232, so that we can monitor various measurement parameters more conveniently. The serial interface is a device that can convert parallel data characters received from the CPU into a continuous serial data stream and send them out, and at the same time, it can convert the received serial data stream into parallel data characters and supply them to the CPU. Generally, the circuit that completes this function is called a serial interface circuit. The circuit diagram is as follows:
![Intelligent fire alarm system circuit module design drawing](http://www.eeworld.com.cn/circuit/upload/f073490e03cf734bc9b10e5aa35c5e34/12d98319e176c1538ca91a5660c6126e.jpg)
Serial communication circuit
Clock module: DS1302 is a trickle charging clock chip launched by DALLAS. It contains a real-time clock/calendar and 31 bytes of static RAM. It communicates with the microcontroller through a simple serial interface. The real-time clock/calendar circuit provides seconds, minutes, hours, and days. , date, month, and year information. The number of days in each month and the number of days in leap years can be automatically adjusted. The clock operation can be decided by AM/PM instructions to adopt 24 or 12 hour format. The DS1302 and the microcontroller can simply communicate in a synchronous serial manner, using only three port lines: RES reset, I/O data line, and SCLK serial clock.
![Intelligent fire alarm system circuit module design drawing](http://www.eeworld.com.cn/circuit/upload/f073490e03cf734bc9b10e5aa35c5e34/285ecb82f6de59fd82e3b9822e6c7152.jpg)
Clock circuit
Review analysis:
Traditional fire alarm systems have problems such as simple structure, low accuracy, false alarms and missed alarms. To address these problems of fire alarm systems in smart buildings, the intelligent fire alarm system based on MSP430F149 has high reliability and stability. , high accuracy. Taking the single-chip computer MSP430F149 as the core and using the ambient temperature and smoke concentration as the basis for judging fire, the early warning of fire is completed. It is mainly composed of microcontroller control module, clock module, smoke concentration measurement module, DS18B20 temperature measurement module, sound and light alarm module, 1602 LCD module and power supply.
- Detailed explanation of the working principle of the parking light circuit
- Audio Adapter Cable - Upgrading Car Audio with MP3 Player
- Hot wire spark plug control circuit
- How to calculate the power loss of RS-485 transceiver THVD1550
- XDH-2 electrocardiograph circuit
- Vehicle electronic fuel gauge circuit
- Electronic mousetrap circuit
- Music calendar using SMC6S37
- 220V AC mains directly drives small relay circuit_3
- JS13 type transistor time relay circuit
- Car anti-theft system module circuit design based on fingerprint recognition
- Practical overheating alarm circuit
- Intelligent fire alarm system circuit module design drawing
- Ultrasonic anti-collision circuit diagram
- Principle circuit diagram of password electronic switch
- Sound activation switch circuit diagram
- Two-wire temperature measurement-frequency converter
- Temperature measurement and control circuit
- Temperature measurement bridge circuit
- Temperature measurement control circuit