EEWORLDEEWORLDEEWORLD

Part Number

Search

7-1415538-8

Description
RT424012WG
CategoryMechanical and electronic products    relay   
File Size402KB,4 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

7-1415538-8 Online Shopping

Suppliers Part Number Price MOQ In stock  
7-1415538-8 - - View Buy Now

7-1415538-8 Overview

RT424012WG

7-1415538-8 Parametric

Parameter NameAttribute value
Brand NameSchrack
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Samacsys Confidence4
Samacsys StatusReleased
Samacsys PartID192822
Samacsys Pin Count8
Samacsys Part CategoryRelay or Contactor
Samacsys Package CategoryOther
Samacsys Footprint Name7-1415538-8-2
Samacsys Released Date2019-12-20 12:24:41
Is SamacsysN
body width12.7 mm
body height15.7 mm
Body length or diameter29 mm
Maximum coil current (DC)0.033 A
Coil operating voltage (DC)8.4 V
Coil power400 mW
Coil release voltage (DC)1.2 V
Coil resistance360 Ω
Maximum coil voltage (DC)12 V
Coil/Input Power TypeDC
Maximum contact current (AC)8 A
Maximum contact current (DC)8 A
Contact/Output Power TypeAC/DC
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
method of packingBOX
physical size29mm x 12.7mm x 15.7mm
GuidelineUL; VDE
Relay actionMOMENTARY
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeSOLDER
Base Number Matches1
General Purpose
Low Power PCB Relays
Power PCB Relay RT2 DC and AC (for global markets)
n
n
n
n
n
n
SCHRACK
2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts
DC or AC coil
5kV/10mm coil-contact, reinforced insulation
Ambient temperature up to 85°C
WG version: product in accordance to IEC60335-1
Reflow version: for THR (Through-Hole Reflow) soldering process
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules.
Zb
Contact Data
(continued)
Mechanical endurance
DC coil
DC coil, reflow version
AC coil
AC coil, reflow version
>30x10
6
operations
>10x10
6
operations
>5x10
6
operations
>2x10
6
operations
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact arrangement
2 form C (CO) or 2 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A, UL: 10A
Limiting continuous current
8A, UL: 10A
Limiting making current, max. 4s, duty factor 10% 15A
Breaking capacity max.
2000VA
Contact material
AgNi 90/10, AgNi 90/10 gold plated,
AgSnO
2
Frequency of operation, with/without load
DC coil
360/72000h
-1
AC coil
360/36000h
-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/10ms
Electrical endurance
see electrical endurance graph
1)
Contact ratings
Type
Contact
IEC 61810
RT424 DC coil C (CO)
RT444 AC coil A (NO)
RT424 AC coil C (CO)
UL 508
RT424 DC coil A/B (NO/NC)
RT424 DC coil A/B (NO/NC)
RT424 DC coil A/B (NO/NC)
EN60947-5-1
RTE24 DC coil A/B (NO/NC)
RTE24 DC coil A/B (NO/NC)
RTE24 DC coil A/B (NO/NC)
EN60730-1
RT424 DC coil A/B (NO/NC)
Load
8A, 250VAC, cosφ=1, 85°C
8A, 250VAC, cosφ=1, 70°C
8A, 250VAC, cosφ=1, 70°C
10A, 250VAC, gen. purpose, 85°C
1/2hp, 240VAC, 85°C
Pilot duty, B300, R300, 85°C
AC15, 250VAC, 3A
DC13, 24VDC, 2A
DC13, 250VDC, 0.2A
6(2)A, 250VAC, 85°C
Cycles
10x10
3
50x10
3
30x10
3
20x10
3
1x10
3
6x10
3
6.050
6.050
6.050
100x10
3
Contact Data
Coil Data
Coil voltage range, DC coil/AC coil
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.5
006
6
4.2
009
9
6.3
012
12
8.4
024
24
16.8
048
48
33.6
060
60
42.0
110
110
77.0
5 to 110VDC / 24 to 230VAC
2
class F
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.4
4.8
6.0
11.0
Coil
resistance
Ω±10%
2)
62
90
200
360
1440
5520
8570
2)
28800
2)
Rated coil
power
mW
403
400
400
400
400
417
420
420
2) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient
temperature +23°C. Other coil voltages on request.
Coil versions, AC coil 50Hz
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
524
24
18.0
615
115
86.3
620
120
90.0
700
200
150.0
730
230
172.5
Release
voltage
VAC
3.6
17.3
18.0
30.0
34.5
Coil
resistance
Ω±15%
3)
350
3)
8100
8800
24350
32500
Rated coil
power
VA
0.76
0.76
0.75
0.76
0.74
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
3) Coil resistance ±10%. All figures are given for coil without pre-energization, at ambient
temperature +23°C, 50Hz. Other coil voltages on request.
10-2014, Rev. 1014
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
1
I would like to ask a serial communication (GPS) garbled problem
I am now doing a simple GPS data reception using the serial port rs232. The received data is garbled. Please give me some advice! Thank you. The code I wrote is as follows redbuff() //Function to read...
treetree600 Embedded System
Learning experience of ARM development board s3c44b0x
[size=4][color=#000000]Our program is to be written into FLASH for storage, but it is copied to SDRAM for execution (if it is executed in ROM, the execution speed will be slower). To achieve this, the...
Jacktang ARM Technology
Programmable analog circuit technology can significantly reduce the current power consumption of mobile phones by 10 to 100 times (Figure)
[Source: http://www.technologyreview.com/read_article.aspx?id=16872ch=infotech Processed and edited by the Chinese Institute of Scientific and Technical Information]For the original English article , ...
fighting Analog electronics
[Sample Show] + HDC1000 Sample Application
[i=s]This post was last edited by yichun417 on 2015-3-26 14:26[/i] I saw other friends' posts talking about the bumpy road of applying for samples. I am relatively lucky. I wrote the following post to...
yichun417 Microcontroller MCU
Modern Communication Technology (4th Edition)
"Modern Communication Technology (4th Edition)" describes advanced communication technology from the perspective of full-process, full-network and network integration based on the layered architecture...
arui1999 Download Centre
Are there other ways to reduce heat and power consumption of MOS besides parallel connection? The current cannot be changed. Although the internal resistance can be...
Are there other ways to reduce heat and power consumption of MOS besides parallel connection? The current cannot be changed. Although the internal resistance can be reduced by parallel connection, it ...
QWE4562009 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2673  1115  1004  1040  517  54  23  21  11  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号