EEWORLDEEWORLDEEWORLD

Part Number

Search

2200AGH100923LA

Description
Strain Guage Sensor, Gage, 0Psi Min, 1000Psi Max, 0.25%, 100mV, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200AGH100923LA Overview

Strain Guage Sensor, Gage, 0Psi Min, 1000Psi Max, 0.25%, 100mV, Cylindrical

2200AGH100923LA Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerGems Sensors & Controls
Reach Compliance Codeunknown
Maximum accuracy(%)0.25%
shellSTAINLESS STEEL
Maximum operating temperature80 °C
Minimum operating temperature-20 °C
Output range100mV
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port typeG1/8 FEMALE
Maximum pressure range1000 Psi
Minimum pressure range
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage15 V
Minimum supply voltage10 V
Termination typePLASTIC CABLE GLAND
Base Number Matches1
How to use A812PG board under XP
How to use A812PG board under XP? Thank you...
flylmind Embedded System
About the computer's power-on self-test
If you set the quickboot in BIOS to disabled, the screen will display the self-test information when you boot up. So if there is an error, when should the self-test alarm sound come out? Does it sound...
wangfuchong Talking
We are designing with AD9361, and AD9364 is released.
A joint press conference was held at Xilinx Beijing Office to jointly promote system-level SDR solutions, release ADI AD9364 products, and show why Zynq & AD936X are very suitable for SDR applications...
jingzhi1221 ADI Reference Circuit
Small boss, big subordinate
Where there is a world, there are factions; where there is a boss, there are subordinates. According to a comrade who has been tortured by various bosses, the bosses born in the 1960s are the best at ...
心仪 Talking about work
Automatic control, is there a simple way to set the parameters of the pi controller?
After adding pi, the open loop transfer function is: num=[-10.3*kp (9.3*kp-10.3*ki) 2e6*kp 2e6*ki]; den=[0.264 2.64 0 0] Do I need to draw a graph or do a calculation? I see that some places draw step...
bszl Analog electronics
The difference between polymer tantalum capacitors and ordinary tantalum capacitors
Tantalum Capacitor Introduction The full name of tantalum capacitor is tantalum electrolytic capacitor (also called tantalum capacitor). It is a type of electrolytic capacitor. It uses metal tantalum ...
Jacktang Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 866  1984  1187  703  1227  18  40  24  15  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号