Film Capacitors FKP 3 680 pF 100 VDC 3x8.5x10 PCM7.5
CategoryPassive components   
File Size337KB,9 Pages
ManufacturerWIMA
Websitehttps://www.wima.de/
Download Datasheet Parametric View All

FKP3D006802B00MJ00 Online Shopping

Suppliers Part Number Price MOQ In stock  
FKP3D006802B00MJ00 - - View Buy Now

FKP3D006802B00MJ00 Overview

Film Capacitors FKP 3 680 pF 100 VDC 3x8.5x10 PCM7.5

FKP3D006802B00MJ00 Parametric

Parameter NameAttribute value
Product CategoryFilm Capacitors
ManufacturerWIMA
Termination StyleRadial
ProductAC and Pulse Film Capacitors
DielectricPolypropylene (PP)
Capacitance680 pF
Voltage Rating AC63 VAC
Voltage Rating DC100 VDC
Tolerance20 %
Lead Spacing7.5 mm
Minimum Operating Temperature- 55 C
Maximum Operating Temperature+ 100 C
Length10 mm
Width3 mm
Height8.5 mm
Capacitance - nF0.68 nF
TypePolypropylenen Film and Foil Capacitors
WIMA FKP 3
Polypropylene (PP) Film and Foil Capacitors for Pulse Applications
in PCM 7.5 mm to 15 mm. Capacitances from 100 pF to 0.22
mF.
Rated Voltages from 63 VDC to 1000 VDC.
Special Features
˜
Pulse duty construction
˜
Very low dissipation factor
˜
Negative capacitance change
versus temperature
˜
Very low dielectric absorption
˜
According to RoHS 2011/65/EU
D
Electrical Data
Capacitance range:
100 pF to 0.22
m
F (E12-values on request)
Rated voltages:
63 VDC, 100 VDC, 250 VDC, 400 VDC,
630 VDC, 850 VDC, 1000 VDC
Capacitance tolerances:
±20%, ±10%, ±5%
Operating temperature range:
–55+ C to +100+ C
Test specifications:
In accordance with IEC 60384-13
Climatic test category:
55/100/56 in accordance with IEC
Insulation resistance
at +20+ C:
5 x 10
5
(mean value: 1 x 10
6
M¸)
Measuring voltage:
U
r
= 63 V: U
test
= 50 V/1 min.
U
r
100 V: U
test
= 100 V/1 min.
Test voltage:
2 U
r
, 2 sec.
Maximum pulse rise time:
1000 V/
m
sec for pulses equal to the
rated voltage
Dielectric absorption:
0.05 %
Temperature coefficient:
–200 x 10
-6
/+ C (general guide)
Dissipation factors
at +20+ C: tan
d
at f
C0.1
mF
0.1
mF
P
C
0.22
mF
3 x 10
-4
6 x 10
-4
Typical Applications
For high frequency applications e.g.
˜
Sample and hold
˜
Timing
˜
LC-Filtering
˜
Oscillating circuits
˜
Audio equipment
1 kHz
4 x 10
-4
10 kHz
5 x 10
-4
100 kHz
10
x 10
-4
Construction
Dielectric:
Polypropylene (PP) film
Capacitor electrodes:
Metal foil
Internal construction:
Voltage derating:
A voltage derating factor of 1.35 % per K
must be applied from +85+ C for DC
voltages and from +75+ C for AC
voltages.
Reliability:
Operational life 300 000 hours
Failure rateP 5 fit (0.5 x U
r
and 40+ C)
Plastic film
Metal foil electrode
Terminating wire
Mechanical Tests
Pull test on pins:
10 N in direction of pins according to
IEC 60068-2-21
Vibration:
6 hours at 10 ... 2000 Hz and 0.75 mm
displacement amplitude or 10 g in
accordance with IEC 60068-2-6
Low air density:
1kPa = 10 mbar in accordance with
IEC 60068-2-13
Bump test:
4000 bumps at 390 m/sec
2
in
accordance with IEC 60068-2-29
Packing
Available taped and reeled.
Detailed taping information and graphs
at the end of the catalogue.
Encapsulation:
Solvent-resistant, flame-retardant plastic
case with epoxy resin seal, UL 94 V-0
Terminations:
Tinned wire.
Marking:
Colour: Red. Marking: Black.
Epoxy resin seal: Yellow
For further details and graphs please
refer to Technical Information.
40
07.16
How to install the lens, pan/tilt, decoder, and converter
Zoom lens or zoom camera (all-in-one) can realize the change of focal length, aperture, and near and far monitoring screen; PTZ can realize the change of monitoring position such as left, right, up, d...
clark Industrial Control Electronics
Friends who want to download the e-book, please look at the pinned information
Now it has been changed to be downloaded to the mailbox, thank you for your support!!!...
totopper Industrial Control Electronics
After GD32F303 SPI is powered on again, the CLK clock signal IO is not output, but the simulation is normal.
Problem: After GD32F303 SPI is powered on again, the CLK clock signal IO is not output, but the simulation is normal.My configuration is as follows: Use SPI0, IO remappingFigure 1 This is the normal t...
sinsnsns GD32 MCU
[Sample] + Optical heart rate monitor reference design supporting BLE connection
[i=s]This post was last edited by Qiangzi00001 on 2014-7-28 01:08[/i] [color=#555555]Texas Instruments (TI) provides users with the service of applying for semiconductor samples[/color][color=#555555]...
强仔00001 TI Technology Forum
SL200 MCU learning board, hardware simulation shows target dll has been cancelled debugger aborted
What is the problem with the hardware emulation "target dll has been cancelled debugger aborted"? Before this, there was a window similar to "connection to target system loss try again .............. ...
auto0811 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2915  882  186  2898  2565  59  18  4  52  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号