EEWORLDEEWORLDEEWORLD

Part Number

Search

54202-S08-04LF

Description
Board to Board u0026 Mezzanine Connectors 8P DR PCB MNT RECPT 2.54 mm x 2.54 mm
CategoryThe connector   
File Size81KB,8 Pages
ManufacturerFCI [First Components International]
Download Datasheet Parametric View All

54202-S08-04LF Online Shopping

Suppliers Part Number Price MOQ In stock  
54202-S08-04LF - - View Buy Now

54202-S08-04LF Overview

Board to Board u0026 Mezzanine Connectors 8P DR PCB MNT RECPT 2.54 mm x 2.54 mm

54202-S08-04LF Parametric

Parameter NameAttribute value
Product CategoryHeaders & Wire Housings
ManufacturerFCI [First Components International]
RoHSDetails
ProductHeaders
TypePin Strip
Number of Positions8 Position
Pitch2.54 mm
Number of Rows2 Row
Mounting Style-
Termination StyleSMD
Mounting AngleVertical
Contact GenderPin (Male)
Contact PlatingGold
PackagingBulk
Contact MaterialPhosphor Bronze
Current Rating3 A
Flammability RatingUL 94 V-0
Housing Gender-
Housing MaterialThermoplastic
Insulation Resistance5000 MOhms
Mating Post Length5.84 mm
Factory Pack Quantity100
Voltage Rating1.5 kV
NUMBER
TYPE
NUMBER
BUS-12-114
PRODUCT SPECIFICATION
TITLE
PAGE
REVISION
Duplex Plated Bergstik® II Headers
1 of 8
AUTHORIZATION
DATE
F
17 May 13
ZK HU
CLASSIFICATION
UNRESTRICTED
1.0
OBJECTIVE
This specification defines the performance, test, quality, and reliability requirements of Duplex Plated
Bergstik® II Headers.
2.0
SCOPE
This specification is applicable to the termination characteristics of the Duplex Plated Bergstik II Headers.
When mated with FCI's Mini PV terminals or other 0.025" pin compatible receptacles on 0.100" centerlines,
this product provides board to board, board to cable, board to discrete wire and board to flex interconnect
capabilities in vertical one, two or three row configurations and right angle one and two row configurations.
This product is Lead Free and meets the requirement of the European Union Directive of Restrictions for
Hazardous Substances (Directive 2002/95/EC)
3.0
GENERAL
This document is composed of the following sections:
Paragraph
1.0
2.0
3.0
4.0
5.0
5.1
5.2
5.3
5.4
6.0
7.0
8.0
9.0
9.1
9.2
9.3
9.4
9.5
9.6
CHART I
TABLE I
Title
Objective
Scope
General
Applicable Documents
Requirements
Qualification
Material
Finish
Design and Construction
Electrical Characteristics
Mechanical Characteristics
Environmental Conditions
Quality Assurance Provisions
Equipment Calibration
Inspection Conditions
Sample Quantity and Description
Acceptance
Qualification Testing
Requalification Testing
IR Reflow Profile
Qualification Testing Matrix
This document is the property of and embodies CONFIDENTIAL and PROPRIETARY information of FCI. No part of the information shown on the
document may be used in any way or disclosed to others without the written consent of FCI.
Copyright FCI.
Form E-3005
Rev E
PDS: Rev :F
GS-01-001
STATUS:Released
Printed: Jun 10, 2013
Are there any electricians here who can develop electronic products to kill rats?
Are there any electricians here who can develop electronic products to kill rats? :loveliness::loveliness:,,,,,,,,There are too many rats now,,it's quite troublesome....
maoshen Talking
BOOST circuit parameter calculation formula
[i=s] This post was last edited by paulhyde on 2014-9-15 03:21 [/i] BOOST circuit parameter calculation formula...
164731940 Electronics Design Contest
Chatting without talking about anything
1. There was a penguin whose home was very far from the polar bear's home. If he walked, it would take him 20 years to get there. One day, the penguin was very bored staying at home, so he decided to ...
zoufeihu Talking
PIC24F16KLxx edge capture causes 'illegal opcode' reset
[i=s]This post was last edited by nos001 on 2016-9-11 16:03[/i] This edge capture is used to measure the cycle time of the AC waveform. It uses the CCP3 pin. The capture setting of PIC24F16KL402 is ve...
nos001 Microchip MCU
Simple C program cannot enter interrupt, please ask the expert
In the process of learning interrupts, the simplest program used is as follows. I use a development board and load it directly. Can I ask an expert why the program cannot enter the interrupt? Thank yo...
pcbrf Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1644  1360  185  556  1617  34  28  4  12  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号