EEWORLDEEWORLDEEWORLD

Part Number

Search

LDA150W-24-SNC

Description
DC Power Cords INPUT MATING HARNESS
CategoryPower/power management   
File Size1MB,17 Pages
ManufacturerCosel
Download Datasheet Parametric View All

LDA150W-24-SNC Online Shopping

Suppliers Part Number Price MOQ In stock  
LDA150W-24-SNC - - View Buy Now

LDA150W-24-SNC Overview

DC Power Cords INPUT MATING HARNESS

LDA150W-24-SNC Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 124 VDC
Output Voltage-Channel 224 VDC
Number of Outputs1 Output
Output Power151.2 W
Open Frame/EnclosedEnclosed
Input Voltage85 VAC to 132 VAC/170 VAC to 264 VAC
Output Current-Channel 16.3 A
IndustryCommercial
Isolation Voltage3 kVAC
Mounting StyleChassis
Length9.9 in
Width3.4 in
Height1.9 in
Efficiency85%
Cooling MethodConvection
Input Frequency47 Hz to 440 Hz
Input Voltage, Max170 VAC to 264 VAC
Input Voltage, Min85 VAC to 132 VAC
Load RegulationRegulated
Maximum Operating Temperature+ 60 C
Mechanical StyleOpen / Enclosed Frame
Minimum Operating Temperature- 10 C
Operating Temperature Range- 10 C to + 60 C
Output Voltage V1, Nominal24 VDC
Factory Pack Quantity15
Unit Weight1.124 lbs
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDA10F
R
LDA
1
2
10
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*2
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA10F-3
6
3V 2.0A
LDA10F-5
10
5V 2.0A
LDA10F-12
10.8
12V 0.9A
LDA10F-15
10.5
15V 0.7A
LDA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
ACIN 200V
LDA10F-3
LDA10F-5
LDA10F-12
LDA10F-15
LDA10F-24
AC85 - 264 1
f
or DC110 - 370
0.25typ (Io=100%)
0.16typ (Io=100%)
47 - 440 or DC
68typ
72typ
74typ
74typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
2
2
0.9
0.7
0.5
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
20max
20max
48max
60max
96max
200max (ACIN 100V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%)
2.85 - 3.6
Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
50
X
21
X
105mm (W
X
H
X
D) /75g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA-2
EEWORLD University Hall ---- 2019 National College Student Electronic Design Competition Explanation and Display
2019 National Undergraduate Electronic Design Competition Explanation and Presentation : https://training.eeworld.com.cn/course/54932019 National Undergraduate Electronic Design Competition Award-winn...
桂花蒸 MCU
An example of using Easy Language to implement serial port control equipment and collect data from the outside
[align=center][font=宋体]Examples of using Easy Language to implement serial port control equipment and collect data from the outside[/font][/align][align=center][font=宋体] [/font][/align][align=center][...
yjtyjt MCU
I always thought that the temperature and humidity sensor was very low.
I used to think that temperature and humidity sensors were very low-end. Now I feel that when I really debug them myself, all kinds of problems will arise. Take a simple SHT10 sensor as an example. It...
小@小哒哒何 Microcontroller MCU
Matthew Effect
The Matthew Effect refers to the phenomenon that the strong become stronger and the weak become weaker. It is widely used in the fields of social psychology, education, finance and science. The Matthe...
白丁 Talking
Any integer frequency division, duty cycle is 50% (VHDL)
[size=6]--Hope it can be helpful to everyone[/size] --**************************************-- --Program name: arbitrary integer division, duty cycle is 50% --**************************************-- ...
Sea_eeworld FPGA/CPLD
Altium Designe Tutorial Collection (very good resource)
[i=s]This post was last edited by a523248304 on 2014-11-7 11:56[/i]Someone sent this to me, I’m sharing it with you guys so you can get to know me better… :sexy: In addition, if engineers need PCB pac...
a523248304 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1862  1227  409  2923  1022  38  25  9  59  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号