EEWORLDEEWORLDEEWORLD

Part Number

Search

LEP240F-36-SN

Description
DC Power Cords INPUT MATING HARNESS
CategoryPower/power management   
File Size524KB,7 Pages
ManufacturerCosel
Download Datasheet Parametric View All

LEP240F-36-SN Online Shopping

Suppliers Part Number Price MOQ In stock  
LEP240F-36-SN - - View Buy Now

LEP240F-36-SN Overview

DC Power Cords INPUT MATING HARNESS

LEP240F-36-SN Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 136 VDC
Number of Outputs1 Output
Output Power241.2 W
Open Frame/EnclosedEnclosed
Input Voltage85 VAC to 264 VAC/120 VDC to 370 VDC
Output Current-Channel 16.7 A
IndustryCommercial
Isolation Voltage3 kV
Mounting StyleChassis
Length252 mm
Width108 mm
Height58 mm
Input Frequency50 Hz/60 Hz
Load RegulationRegulated
Power - Convection240 W
Factory Pack Quantity10
Unit Weight2.359 lbs
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LEP100F
LEP 100
1
2
3
F
4
-24
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*1 *6
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
R
Recommended EMI/EMC Filter
NAC-06-472
LEP
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
DC OUTPUT
LEP100F-24
+24V 4.2(Peak 7)A
LEP100F-36
+36V 2.8(Peak 4.7)A
LEP100F-48
+48V 2.1(Peak 3.5)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*
2
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
3
RIPPLE[mVp-p]
-10 - 0
C
*
3
0 to +50
C
*
3
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
3
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
*
5
INPUT-FG
OUTPUT
-
RC-FG
*
5
OUTPUT-RC
*
5
,HUMID.AND ALTITUDE
OPERATING TEMP.
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
LEP100F-24
LEP100F-36
LEP100F-48
AC85 - 264 1
f
or DC 120 - 370
1.4typ (Io=100%)
0.7typ (Io=100%)
50/60 (47 - 63) or DC
81typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
84typ (Io=100%)
85typ (Io=100%)
85typ (Io=100%)
0.98typ (Io=100%)
0.93typ (Io=100%)
15typ (Io=100%) (At cold start) (Ta=25
C
)
30typ (Io=100%) (At cold start) (Ta=25
C
)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+24
+36
+48
0 - 4.2 (Peak 7)
0 - 2.8 (Peak 4.7)
0 - 2.1 (Peak 3.5)
(Peak 168)
(Peak 169.2)
100.8
100.8
100.8 (Peak 168)
48max
48max
48max
76max
90max
150max
120max
120max
150max
160max
160max
300max
150max
150max
250max
180max
180max
350max
120max
150max
240max
145max
180max
300max
48max
48max
48max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.4 - 26.4
26.4 - 39.6
39.6 - 52.8
23.0 - 25.0
35.0 - 37.0
46.0 - 50.0
Works over 101% of peak current and recovers automatically
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +70
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
*
7
75
X
35
X
222mm [2.95
X
1.38
X
8.74 inches] (W
X
H
X
D) /380g max (with chassis & cover : 650g max)
Convection
*5
*6
*7
*
*
*
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Specification is changed at option, refer to Instruction Manual 6.
*2
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEP-2

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1214  878  388  1396  352  25  18  8  29  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号