Railway/Transportation system applications including communications systems, informa-
tion display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110B24C200BL
V1 1 0 B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
75W, 100W
5V
100W, 150W
8V
150W
12V
150W, 200W
15V
150W, 200W
24V
150W, 200W
28V
150W, 200W
36V
150W, 200W
48V
150W, 200W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
=
8V
12
=
12V
15
=
15V
24
=
24V
28
=
28V
36
=
36V
48
=
48V
110V Mini Family
Page 1 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Mini Family
Page 2 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Mini Family
Page 3 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 100W (e.g. S110B3V3C100BL, V110B3V3C100BL)
Parameter
Efficiency
S110B3V3C100BL (enhanced efficiency)
V110B3V3C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.1
81.5
4.14
Typ
86.5
82.6
80
4.3
2.6
±0.02
34.8
34.8
Max
Unit
%
100
4.46
3.4
±0.2
30.3
41
41
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
3.3
V
OUT
, 75W (e.g. S110B3V3C75BL, V110B3V3C75BL)
Parameter
Efficiency
S110B3V3C75BL (enhanced efficiency)
V110B3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.2
81.0
4.14
Typ
86.0
81.9
80
4.3
2.6
±0.02
26.1
26.1
Max
Unit
%
100
4.46
3.6
±0.2
22.73
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
5
V
OUT
, 150W (e.g. S110B5C150BL, V110B5C150BL)
Parameter
Efficiency
S110B5C150BL (enhanced efficiency)
V110B5C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.4
83.9
6.03
Typ
88.5
84.8
85
6.25
5.3
±0.02
34.5
34.5
Max
Unit
%
107
6.47
7.5
±0.2
30
40.5
40.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
5
V
OUT
, 100W (e.g. S110B5C100BL, V110B5C100BL)
Parameter
Efficiency
S110B5C100BL (enhanced efficiency)
V110B5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.5
6.03
Typ
86.0
81.9
240
6.25
3.4
±0.02
23
23
Max
Unit
%
300
6.47
4.4
±0.2
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
110V Mini Family
Page 4 of 14
Rev 3.6
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8
V
OUT
, 150W (e.g. S110B8C150BL, V110B8C150BL)
Parameter
Efficiency
S110B8C150BL (enhanced efficiency)
V110B8C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.3
85.5
9.36
Typ
89.0
86.8
200
9.7
5.2
±0.02
21.6
21.6
Max
Unit
%
250
10.1
6.4
±0.2
18.75
25.4
25.4
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
19.1
13.1
12
V
OUT
, 200W (e.g. S110B12C200BL, V110B12C200BL)
Parameter
Efficiency
S110B12C200BL (enhanced efficiency)
V110B12C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.9
86.0
13.7
Typ
89.0
87.2
185
14.3
7
±0.02
19.2
19.2
Max
Unit
%
232
14.9
8.2
±0.2
16.67
22.6
22.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
17
11.6
12
V
OUT
, 150W (e.g. S110B12C150BL, V110B12C150BL)
Parameter
Efficiency
S110B12C150BL (enhanced efficiency)
V110B12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.9
87.0
13.7
Typ
90.0
88.0
160
14.3
4.7
±0.02
14.4
14.4
Max
Unit
%
200
14.9
5.8
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
15
V
OUT
, 200W (e.g. V110B15C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
17.1
Typ
88.1
240
17.8
7.3
±0.02
15.3
15.3
Max
300
18.5
8.2
±0.2
13.33
18
18
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
by chunyang1. Preset a 16-bit register (hereinafter referred to as CRC register) and convert its content to hexadecimal number 0xFFFF;2. XOR the first byte of the first data to be calculated, i.e. the...
As China's No. 1 professional manager, Tang Jun said that his life has no adventures and he has never taken any shortcuts. "If I can succeed, why can't you?" When I joined Microsoft, I was just an ord...
A few days ago, my wife scolded me, "Look at your broken electric abacus, it's so dirty, clean it." Since the queen has ordered us to change it, so I went straight to Xiubo Ma Street (SuperMaket) and ...
[i=s] This post was last edited by 5之丹公英 on 2016-5-7 21:51 [/i] I saw the classification of op amps on the ADI official website,I am going to make an output conditioning for a capacitive sensor recent...
First of all, my WINCE system supports WinSock2, so I can use the functions of the WinSock2 library. In my program, I want to create a multicast socket creation function: SOCKET WSASocket( int af, int...
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
In recent years, the government has increasingly supported electric vehicles, and the number of electric vehicles has increased. Observant drivers will notice that there are many more green license...[Details]
1. Multi-channel DAC technology bottleneck
Currently,
the development of multi-channel DAC technology focuses on two core challenges.
First, industrial applications urgently ...[Details]
A human-machine interface (HMI) refers to the platform used by people to operate a PLC. This platform provides an interface between programs and humans, serving as a medium for information transmis...[Details]
Shenzhen Baowei Power Supply high frequency pure sine wave power, communication inverter power supply has two communication interfaces, RS232 and R485 interfaces, their functions and characteristic...[Details]
Previously, Positive Motion Technology shared with you the firmware upgrade of motion controller, ZBasic program development, ZPLC program development, communication with touch screen and input/out...[Details]
There are more and more electric vehicles. Recently, I have heard some news about electric vehicles performing poorly in winter. I would like to briefly introduce whether heat pump technology is mo...[Details]
introduction
In recent years, multi-touch has emerged as a new alternative to traditional human-computer interaction. It eliminates the need for keyboards and mice, enabling simultaneous inter...[Details]
On August 14, Chinese researchers broke through the bottleneck of energy density and application performance of existing traditional lithium-ion batteries and developed soft-pack batteries with an ...[Details]
With the global penetration rate of new energy vehicles projected to exceed 45% by 2025, and the industry's transformation entering its second half, the era of intelligentization, LiDAR has rapidly...[Details]
Ever since smartphones became popular, their battery life has become a major concern. Although current phones often have large batteries of 3,000 to 4,000 mAh, heavy users still have to charge thei...[Details]
As urbanization accelerates and public safety demands continue to rise, traditional surveillance systems are gradually exposing their limitations due to their reliance on manual oversight, delayed ...[Details]
As the automotive industry enters a new era of intelligence and electrification, the core competitiveness of automobiles is undergoing a fundamental shift. Software is replacing mechanical componen...[Details]
The importance of a gearbox to a car is self-evident. The performance of a vehicle, including its torque and speed, are all determined by the gearbox. Electric vehicles are different from tradition...[Details]