NTS505-M

Description
Switching Power Supplies 24V, 500W MEDICAL
CategoryPower/power management   
File Size1013KB,5 Pages
ManufacturerArtesyn
Websitehttp://www.artesyn.com
Download Datasheet Parametric Compare View All

NTS505-M Online Shopping

Suppliers Part Number Price MOQ In stock  
NTS505-M - - View Buy Now

NTS505-M Overview

Switching Power Supplies 24V, 500W MEDICAL

NTS505-M Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerArtesyn
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 124 VDC
Number of Outputs1 Output
Output Power500 W
Open Frame/EnclosedEnclosed
Input Voltage90 VAC to 264 VAC, 120 VDC to 300 VDC
Output Current-Channel 18.3 A
IndustryMedical
Mounting StyleChassis
Length177.8 mm
Width101.6 mm
Height38.1 mm
Input Frequency47 Hz to 63 Hz
Power - Convection200 W
Power - Forced Air500 W with 30 CFM
Factory Pack Quantity42
Unit Weight2.601 lbs
POWER
Data Sheet
Total Power:
200 - 500 Watts
Input Voltage:
85 - 264 Vac
120 - 300 Vdc
# of Outputs:
Single
SPECIAL FEATURES
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Active power factor correction
IEC EN61000-3-2 compliance
Remote sense
Power fail and remote inhibit
Single wire current sharing
Built-in EMI filter
Low output ripple
5 V standby
12 V fan output
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
Built in OR-ing diode/FET
Optional fan cover (-CF suffix)
Optional end fan cover (-CEF suffix)
PMBus compliant
RoHS compliant
Digital I
2
C interface
Two year warranty
POE isolation on NTS508-M
NTS500-M Series
500 Watts
Medical
Electrical Specifications
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
85 - 264 Vac (wide range)
47 - 63 Hz
50 A max., cold start @ 25 °C
85% typical at full load, nominal line
FCC Class B conducted and radiated; CISPR22 Class B conducted
and radiated; EN55022 Class B conducted and radiated;
VDE0878PT3 Class B conducted and radiated.
< 0.3 mA @ 50/60 Hz, 264 Vac input
Safety ground leakage
current
Output
Maximum power
Adjustment range
Standby output
200 W for convection; 500 W with 30 CFM forced air
± 5%
5 V @ 1 A convection, 2 A forced air, regulated, ± 5%
12 V @ 1 A, -5 %, +7%, 0.5 A for -CF version
20 ms @ 500 W load, 115 VAC nominal line at factory voltage setting
Short circuit protection on all outputs. Case overload protected @
115 - 130% above peak rating
20 - 35% above nominal output
SAFETY
ƒ
ƒ
ƒ
ƒ
TUV:
cULus:
CB:
CE:
60601-1
60601-1
Certificate & report
Mark (LVD)
Fan output
Hold-up time
Overload protection
Overvoltage protection

NTS505-M Related Products

NTS505-M NTS503-M-CF NTS503-M NTS508-M-CEF NTS508-M-CF NTS505-M-CEF NTS503-M-CEF
Description Switching Power Supplies 24V, 500W MEDICAL Switching Power Supplies 12v, 500W, 4"x 7" w/cover u0026 top fan Switching Power Supplies 12v, 500W, 4"x 7" Medical Switching Power Supplies 48V 500W 4" x 7" w/cover u0026end fan,Med Switching Power Supplies 48v, 500W, 4"x 7" w/cover u0026 top fan Switching Power Supplies 24V 500W 4" x 7" w/cover u0026end fan,Med Switching Power Supplies 12V 500W 4" x 7" w/cover u0026end fan,Med
Product Category Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies Switching Power Supplies
Manufacturer Artesyn Artesyn Artesyn Artesyn Artesyn Artesyn Artesyn
RoHS Details Details Details Details Details Details Details
Product Switching Supplies Switching Supplies Switching Supplies Switching Supplies Switching Supplies Switching Supplies Switching Supplies
Output Voltage-Channel 1 24 VDC 12 V 12 V 48 VDC 48 VDC 24 VDC 12 VDC
Number of Outputs 1 Output 1 Output 1 Output 1 Output 1 Output 1 Output 1 Output
Output Power 500 W 500 W 500 W 500 W 500 W 500 W 500 W
Open Frame/Enclosed Enclosed Enclosed Enclosed Enclosed Enclosed Enclosed Enclosed
Input Voltage 90 VAC to 264 VAC, 120 VDC to 300 VDC 90 VAC to 264 VAC, 120 VDC to 300 VDC 90 VAC to 264 VAC, 120 VDC to 300 VDC 90 VAC to 264 VAC, 120 VDC to 300 VDC 90 VAC to 264 VAC, 120 VDC to 300 VDC 90 VAC to 264 VAC, 120 VDC to 300 VDC 90 VAC to 264 VAC, 120 VDC to 300 VDC
Output Current-Channel 1 8.3 A 16.6 A 16.6 A 4.2 A 4.2 A 8.3 A 16.6 A
Mounting Style Chassis Chassis Chassis Chassis Chassis Chassis Chassis
Length 177.8 mm 177.8 mm 177.8 mm 177.8 mm 177.8 mm 177.8 mm 177.8 mm
Width 101.6 mm 101.6 mm 101.6 mm 101.6 mm 101.6 mm 101.6 mm 101.6 mm
Height 38.1 mm 38.1 mm 38.1 mm 38.1 mm 38.1 mm 38.1 mm 38.1 mm
Input Frequency 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz
Power - Convection 200 W 200 W 200 W 200 W 200 W 200 W 200 W
Power - Forced Air 500 W with 30 CFM 500 W with 30 CFM 500 W with 30 CFM 500 W 500 W 500 W with 30 CFM 500 W with 30 CFM
Unit Weight 2.601 lbs 2.601 lbs 2.601 lbs 2.601 lbs 2.601 lbs 2.601 lbs 2.601 lbs
Factory Pack Quantity 42 36 42 36 36 36 -
Commercial/Medical - Medical Medical Medical Medical - -
Seeking intelligent power supply monitoring and management software solution (paid service)
This solution includes 3 PWMs, 6 A/D inputs, 7 bidirectional I/Os, and 1 D/A output. It requires an 8-bit microcontroller from PIC, Renesas, or ATMEL. If you are interested, please contact 18923776056...
vpgpu MCU
【FreeUI v0.2】Analysis of simple mobile phone interface design
[size=4] The previous [color=#0000ff][b]FreeUI v0.1[/b][/color] is not that good, and [url=home.php?mod=space&uid=664340]@armink[/url] [url=home.php?mod=space&uid=390804]@kdy[/url] and my friend @鸟小菜 ...
辛昕 Programming Basics
Can you help me figure out why the PWM wave is not generated?
The chip I use is LM3S2B93, Keil4 project, when debugging PWM, it can't generate PWM, other functions are normal, can you help me find out what's going on ~ urgent! ! unsigned long gSysClock = 1200000...
hwttyzh ARM Technology
iar avr twi multi-slave source code
来源于AVR网站[code]/***************************************************************************** * * Atmel Corporation * * File: main.c * Compiler: IAR EWAAVR 2.28a/3.10c * Revision: $Revision: 2516 $ * D...
bootloader Microchip MCU
Are variables always equal to 0 in IAR debugging?
I am new to IAR. I downloaded 8.30. During debugging, I found that the variables in the watch are always 0. Please help me....
sxbug MCU
How to read the ID in EPCs in fpga
I use epcs M25p16 in my altera epcs6E22. I want to encrypt my system. M25P16 has a unique ID. If I can read it, I can encrypt it. But I don't know how to read it in FPGA. The datasheet says this: [col...
liwenz FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 762  1245  236  778  2606  16  26  5  53  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号