320W Single Output Switching Power Supply
Features :
HLG-320H
series
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 95%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet location
5 years warranty (Note.10)
F
110
M
M
SELV
IP65 IP67
HLG-320H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal
potentiometer.
B : IP67 rated. Constant current level adjustable through output cable
with 1~10Vdc or PWM signal or resistance.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
D
(option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
HLG-320H-12
12V
22A
264W
CONSTANT CURRENT REGION
Note.4
6 ~12V
HLG-320H-15
15V
7.5 ~ 15V
19A
285W
150mVp-p
HLG-320H-20
20V
10 ~ 20V
15A
300W
150mVp-p
17 ~ 22V
7.5 ~ 15A
1.5%
0.5%
1.0%
HLG-320H-24
24V
12 ~ 24V
13.34A
320.16W
150mVp-p
21 ~ 26V
HLG-320H-30
30V
15 ~ 30V
10.7A
321W
200mVp-p
26 ~ 32V
HLG-320H-36
36V
18 ~ 36V
8.9A
320.4W
250mVp-p
32 ~ 39V
HLG-320H-42
42V
21 ~ 42V
7.65A
321.3W
250mVp-p
38 ~ 45V
3.8 ~ 7.65A
1.0%
0.5%
0.5%
HLG-320H-48
48V
24 ~ 48V
6.7A
321.6W
250mVp-p
43 ~ 52V
3.35 ~ 6.7A
1.0%
0.5%
0.5%
HLG-320H-54
54V
27 ~ 54V
5.95A
321.3W
350mVp-p
49 ~ 58V
2.97 ~ 5.95A
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
10.8 ~ 13.5V 13.5 ~ 17V
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.) (230Vac)
EFFICIENCY (Typ.) (277Vac)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
Note.7
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Note.4
Can be adjusted by internal potentiometer or through output cable
11 ~ 22A
3.0%
0.5%
2.0%
9.5 ~ 19A
2.0%
0.5%
1.5%
6.67 ~ 13.34A 5.35 ~ 10.7A 4.45 ~ 8.9A
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.8
2500ms, 80ms at full load
230VAC /115VAC
15ms at full load
Note.5
90 ~ 305VAC
230VAC /115VAC
127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
91%
91.5%
92.5%
93.5%
94%
94%
94.5%
95%
95%
95%
95%
95%
95%
95%
94%
93%
3.5A / 115VAC
1.65A / 230VAC
COLD START 75A/230VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
33 ~ 37V
14 ~ 17V
17.5 ~ 21V 22.5 ~ 27V
27 ~ 33V
40 ~ 46V
46.5 ~ 53V
53.5 ~ 60V
59 ~ 65V
94.5%
94.5%
1.45A / 277VAC
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100
10 (RTH2)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
-40 ~ +70
-40 ~ +80
0.03%/
(Refer to "Derating Curve")
, 10 ~ 95% RH
(0 ~ 50
)
20 ~ 95% RH non-condensing
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750,
CSA C22.2 No. 250.0-08,
EN61347-1, EN61347-2-13 independent (except for HLG-320H C type)
, J61347-1, J61347-2-13,
IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
157.1Khrs min. MIL-HDBK-217F (25 )
252*90*43.8mm (L*W*H)(HLG-320H-Blank/A/B/D)
256*90*43.8mm (L*W*H)(HLG-320H-C)
1.88Kg; 8pcs/16Kg/0.83CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
MeanWell Direct Tel: +44 (0)118 970 3858 E-mail: sales@meanwelldirect.co.uk