Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
50
X
21
X
105mm (W
X
H
X
D) /75g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA-2
LDA10F
External view
LDA
Performance data
¡
STATIC CHARACTERISTICS (LDA10F-5 )
¡
RISE TIME & FALL TIME (LDA10F-5 )
¡
OVERCURRENT CHARACTERISTICS (LDA10F-5 )
¡
DERATING CURVE
LDA-3
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDA15F
R
LDA
1
2
15
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*2
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA15F-3
9
3V 3.0A
LDA15F-5
15
5V 3.0A
LDA15F-12
15.6
12V 1.3A
LDA15F-15
15
15V 1.0A
LDA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
ACIN 200V
LDA15F-3
LDA15F-5
LDA15F-12
LDA15F-15
LDA15F-24
AC85 - 264 1
f
or DC110 - 370
0.37typ (Io=100%)
0.23typ (Io=100%)
47 - 440 or DC
70typ
74typ
76typ
76typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
50
X
21
X
125mm (W
X
H
X
D) /95g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA-4
LDA15F
External view
LDA
Performance data
¡
STATIC CHARACTERISTICS (LDA15F-5 )
¡
RISE TIME & FALL TIME (LDA15F-5 )
¡
OVERCURRENT CHARACTERISTICS (LDA15F-5 )
¡
DERATING CURVE
LDA-5
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDA30F
R
LDA
1
2
30
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*2
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA30F-3
18
3V 6.0A
LDA30F-5
30
5V 6.0A
LDA30F-12
30
12V 2.5A
LDA30F-15
30
15V 2.0A
LDA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
ACIN 200V
LDA30F-3
LDA30F-5
LDA30F-12
LDA30F-15
LDA30F-24
AC85 - 264 1
f
or DC110 - 370
0.8typ (Io=100%)
0.4typ (Io=100%)
47 - 440 or DC
70typ
75typ
77typ
78typ
79typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
55
X
26
X
133mm (W
X
H
X
D) /200g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
German ACAM patented product TDC-GP2 time interval measurement chip TDC-GP2 is a new generation of ACAM's general TDC series products. It has higher accuracy and smaller package, especially suitable f...
1. Example test (divided into Manly's example and Xpresso's comparison) 1.1 LPCxPresso The LPCOpen example was installed. Because there is no board test, only the program was analyzed. It is found to ...
Hello everyone, my FPGA is SP601, petalinux is version 0.4, I wrote a simple web server on petalinux, it can run on the board with FPGA transplanted with petalinux, but I can't access the web page thr...
I originally wanted to make some hardware myself and develop it towards productization, and get familiar with the hardware of Renesas MCU. However, since this MCU of Renesas is relatively simple and h...
On August 24th, Jin Yuzhi, CEO of Huawei's Intelligent Automotive Solutions BU, announced the first automotive application of Huawei Qiankun's unique Limera technology. This technology eliminates t...[Details]
Robotics
has become
LiDAR
's "second growth curve."
While LiDAR was still battling with its "pure vision" rivals in the automotive field, another field ignited the demand f...[Details]
On August 21, WeRide officially launched WePilot AiDrive, a one-stage end-to-end assisted driving solution developed in cooperation with Bosch. This comes only half a year after the two parties' "t...[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
The all-new MG4 was recently officially announced on the Ministry of Industry and Information Technology's (MIIT) new vehicle announcement. The all-new MG4's semi-solid-state battery version addres...[Details]
A half-bridge is an inverter topology for converting DC to AC. A typical half-bridge circuit consists of two controller switches, a three-wire DC power supply, two feedback diodes, and two capacito...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
On August 21st, BYD announced the launch of its next-generation "Little White Pile" product, the "Lingchong"
charging
pile
, which is now available for general sale. This charging pile feat...[Details]
In the period after the switching power supply achieved the "20 kHz" revolution in the 1970s, although improvements and enhancements were made in circuit technology, the development level of the se...[Details]
Civilian internal combustion engines operate in the range of approximately 1000-4000 rpm. This results in the engine's kinetic energy being ineffective at low or high rpm, making starting difficult...[Details]
As a pioneer in the new smart home concept, robot vacuums have captured a significant market share. Robot vacuums, also known as automatic sweepers, smart vacuums, or robot vacuums, are smart home ...[Details]
introduction
The widespread use of air conditioner communication circuits began with the rise of household inverter air conditioners. With China's energy conservation and emission reduction in...[Details]
With the development of vehicle technology, there are more types of cars. Cars are divided into hybrid, pure electric vehicles, and fuel vehicles. For hybrid cars, they are divided into plug-in hyb...[Details]
In machine vision systems, light sources play a crucial role. Choosing the right light source is a key factor in determining the success or failure of the entire system. The main purpose of the lig...[Details]
On August 18, Zhiyuan Robotics released information showing that the company's entire product line is officially on sale.
The full range of products launched this time includes six major produ...[Details]