25W AC-DC Triple Output Industrial Adaptor
GP25A
series
UL60950-1
EN60950-1
IEC60950-1
■
Features
•
Universal AC input / Full range
•
3 pole AC inlet IEC320-C14, Class I power unit
•
No load power consumption < 0.3W
•
Energy efficiency level
Ⅵ
•
Comply with EISA 2007/DoE
•
Protections: Short circuit / Overload / Over voltage
•
Fully enclosed plastic case
•
-20 ~ +70
℃
working temperature
•
LED indicator for power on
•
Dual output available (optional)
•
±
16V /+48V also available for video system
(optional, order NO. : GP25A58F-R1B)
■
Applications
•
Consumer electronic devices
•
Telecommunication devices
•
Office facilities
•
Industrial equipments
•
3 years warranty
■
Description
GP25A is a 25W triple-output desktop type green adaptor series, complying with the mandatory energy
saving standard USA EISA 2007/DoE (Level
Ⅵ
). Adopting Class
I
design and utilizing the standard inlet
IEC320-C14, it is designed with FG and uses the 94V-0 flame retardant plastic enclosure, which can
effectively prevent electric shock hazards. This series operates from 90~264VAC and offers three models
with the output voltage sets +5V/+12V/-5V, +5V/+12V/-12V and +5V/+15V/-15V. Its supreme advantages
includes the less-than-0.3W no load power consumption, the capability of working under -2 0 ~+70
℃
ambient temperature, complete protection functions and three-year warranty and the compliance to the
international safety certification such as CB, TUV, UL, CE and FCC. GP25A is a multiple-output green
adaptor with high safety, high reliability and high quality.
■
Model Encoding
GP 25
A
13A - R1B
DC plug type
Output voltage
IEC320-C14 3pin AC input
Rated wattage
Series name
File Name:GP25A-SPEC 2018-01-15
{
R1B: Plug for standard model, power DIN 5 pin
Other options available by customer requested (see Page 4)
25W AC-DC Triple Output Industrial Adaptor
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED SET CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
GP25A13A-R1B
GP25A13A
Note.2
5V
GP25A
GP25A14E-R1B
GP25A14E
12V
1A
0.2 ~ 1A
120mVp-p
±1.0%
±5.0%
-12V
0.3A
0.1 ~0.3A
50mVp-p
±1.0%
±3.0%
5V
2.5A
0.5 ~ 2.5A
29W
100mVp-p
±5.0%
±1.0%
±5.0%
150mVp-p
±1.0%
±5.0%
15V
0.8A
0.1 ~ 0.8A
series
GP25A13D-R1B
GP25A13D
-5V
0.3A
0.1 ~ 0.3A
50mVp-p
±1.0%
±3.0%
5V
2.5A
0.5 ~ 2.5A
28W
60mVp-p
±5.0%
±1.0%
±5.0%
12V
1.2A
0.2 ~ 1.2A
100mVp-p
±1.0%
±5.0%
-15V
0.3A
0.1 ~ 0.3A
50mVp-p
±1.0%
±3.0%
2.5A
0.5 ~ 2.5A
28.5W
RIPPLE & NOISE (max.)
Note.3
50mVp-p
VOLTAGE TOLERANCE
Note.4
±5.0%
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
Note.5
±1.0%
Note.6
±5.0%
Note.7
90 ~ 264VAC
-5.0 ~ +10%
±3.0%
-5.0 ~ +5.0%
±3.0%
-5.0 ~ +15%
±3.0%
SETUP, RISE, HOLD UP TIME
800ms, 50ms, 20ms / 230VAC
135~ 370VDC
47 ~ 63Hz
80%
0.8A / 100VAC
0.75mA / 240VAC
0.4A / 230VAC
Cold start 30A / 115VAC
1200ms, 50ms, 16ms / 115VAC at full load
INPUT
80%
60A / 230VAC
80.5%
PROTECTION
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
110 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode(5V only), output short
-20 ~ +70
℃
(Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85
℃
, 10 ~ 95% RH non-condensing
±
0.03% /
℃
(-20 ~ 40
℃
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
IEC60950-1, UL60950-1, CSA22.2, EN60950-1,
EAC TP TC 004
approved
I/P-O/P:4242VDC , I/P-FG:2121VDC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Parameter
Conducted emission
EMC EMISSION
SAFETY &
EMC
(Note. 8)
Standard
Test Level / Note
Radiated emission
Harmonic current
EN55032(CISPR32),FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
Class B
EN55032(CISPR32),FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
Class B
EN61000-3-2
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-11
Class A
-------
Test Level /Note
Level 3, 8KV air; Level 2, 4KV contact
Level 2, 3V/m
Level 2, 1KV
Level 3, 1KV/L-N, 2KV/L,N-PE
Level 2, 3V
>
95% dip 0
.
5 periods, 30% dip 25 periods,
>
95% interruptions 250 periods
Voltage flicker
Parameter
ESD
RF field
susceptibility
EMC IMMUNITY
EFT bursts
Surge susceptibility
Conducted susceptibility
Voltage dips , interruption
LIFE
MTBF
OTHERS
DIMENSION
PACKING
PLUG
CABLE
3 years : 100% load 40
℃
, 8hours
/
day
620K hrs min. MIL-HDBK-217F (25
℃
)
107.5*67*36mm (L*W*H)
0.3kg; 54pcs / 20kg / CARTON
See page 4
See page 4
CONNECTOR
1.All parameters are specified at 230VAC input, rated load, 25
℃
70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
NOTE
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1
μ
f & 47
μ
f capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.When measured between the light load (20% of rated load) and full load, the load regulation is within
±
5% whereas the cross regulation is within
±
15%.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:GP25A-SPEC 2018-01-15