Controllers M3 Smart StarterKit 100-240AC XD26
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size94KB,4 Pages
ManufacturerCrouzet
Download Datasheet Parametric View All

88974085 Online Shopping

Suppliers Part Number Price MOQ In stock  
88974085 - - View Buy Now

88974085 Overview

Controllers M3 Smart StarterKit 100-240AC XD26

88974085 Parametric

Parameter NameAttribute value
Product CategoryControllers
ManufacturerCrouzet
RoHSDetails
Analog / DigitalDigital
TypeStarter Kit
Display TypeBacklit LCD
Operating Supply Voltage100 VAC to 240 VAC
MountingDIN Rail
FeaturesOpen to standard extensions, CB, CD, XD, XB, XR, XE, 4 line LCD display
Number of Inputs16
Number of Outputs10
Output TypeRelay
Factory Pack Quantity1
02/11/2015
www.crouzet.com
"Expandable" range starter kit Kit 26 Part number 88974085
Each kit includes :
- 1 expandable Millenium 3 (XD26)
- 1 USB link cable : PC →Millenium 3
- 1 interactive CD ROM including the software workshop, application library and technical brochures, 1 CD-ROM including the library of
specific functions
Part numbers
Type
88974085
Kit 26
Inputs
16 digital
Outputs
10 relays (8 x 8 A relay and 2 x 5 A relay)
Supply
100 →240 V AC
Specifications
General environment characteristics for CB, CD, XD, XB, XR and XE product types
Certifications
Conformity to standards (with the low voltage directive
and EMC directive)
CE, UL, CSA, GL
IEC/EN 61131-2 (Open equipment)
IEC/EN 61131-2 (Zone B)
IEC/EN 61000-6-2,
IEC/EN 61000-6-3 (*)
IEC/EN 61000-6-4
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Not included
In accordance with IEC/EN 60529 :
IP40 on front panel
IP20 on terminal block
3 in accordance with IEC/EN 60664-1
Degree : 2 in accordance with IEC/EN 61131-2
Operation : 2000 m
Transport : 3048 m
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Immunity to ESD
IEC/EN 61000-4-2, level 3
Immunity to radiated electrostatic fields
IEC/EN 61000-4-3
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Voltage dips and breaks (AC)
IEC/EN 61000-4-11
Immunity to damped oscillatory waves
IEC/EN 61000-4-12
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1
(*) Except configuration (88 970 1.1 or 88 970 1.2) +
(88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
-20 →+70 °C 
except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure)
in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
-40 →+80 °C in accordance with IEC/EN 60068-2-1 and
IEC/EN 60068-2-2
95 % max. (no condensation or dripping water) in accordance with
IEC/EN 60068-2-30
On symmetrical DIN rail, 35 x 7.5 mm and 35 x 15 mm, or on panel (2 x Ø 4 mm)
Flexible wire with ferrule =
1 conductor : 0.25 to 2.5 mm
2
(AWG 24...AWG 14)
2 conductors 0.25 to 0.75 mm
2
(AWG 24...AWG 18)
Semi-rigid wire =
1 conductor : 0.2 to 2.5 mm
2
(AWG 25...AWG 14)
Rigid wire =
1 conductor : 0.2 to 2.5 mm
2
(AWG 25...AWG 14)
2 conductors 0.2 to 1.5 mm
2
(AWG 25...AWG 16)
Tightening torque =
0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)
Also valid for spring cage connectors (ref 88 970 313 and 88 970 317 for the RBT range)
Earthing
Protection rating
Overvoltage category
Pollution
Max operating Altitude
Mechanical resistance
Resistance to electrostatic discharge
Resistance to HF interference
Conducted and radiated emissions
Operating temperature
Storage temperature
Relative humidity
Mounting
Screw terminals connection capacity
Processing characteristics of CB, CD, XD & XB product types
LCD display
CD, XD : Display with 4 lines of 18 characters
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
Touch screen timing interruption problem
In the touch screen driver, there is a timer interrupt, which is the logical interrupt gIntrTouchChanged. I don't understand 1. I have seen many timers using TIMER3. Is it necessary to use TIMER3? If ...
smnh1 Embedded System
PIC Microcontroller C Language Programming Guide for Beginners
PIC microcontroller C language programming guide for beginners....
liuwenliang2012 Microchip MCU
Ask a question about CDMA dialing
The module I use has a built-in PPP dial-up protocol. After the PPP verification is successful, can I directly use the encapsulation class such as CSocket in MFC to send things to the network using ud...
talent11 Embedded System
The advantages of series resonance are becoming more and more prominent
No matter what kind of instrument you choose, you certainly hope that its value is very high and it meets your needs. The same is true for series resonance . You also hope to understand its performanc...
ZXCQWEASD Integrated technical exchanges
Recommend a good website to learn analog electronics
Students who are interested in RF technology may want to visit the crystal radio forum, especially the crystal radio column. There are many retired or soon-to-retire elderly people there. Some of them...
quanzx Analog electronics
Introducing 4 solutions for LED street light power supply design
[b][size=5][color=red] LED street lights are a very important application in LED lighting. Under the premise of energy saving and power saving, the trend of LED street lights replacing traditional str...
qwqwqw2088 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 852  445  1028  725  1269  18  9  21  15  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号