Illuminated Pushbutton Switches 16A, 250VAC 19mm 2 POLE BRIGHT BLU
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size709KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

3-101-010 Online Shopping

Suppliers Part Number Price MOQ In stock  
3-101-010 - - View Buy Now

3-101-010 Overview

Illuminated Pushbutton Switches 16A, 250VAC 19mm 2 POLE BRIGHT BLU

3-101-010 Parametric

Parameter NameAttribute value
Product CategoryIlluminated Pushbutton Switches
ManufacturerSCHURTER
RoHSDetails
Contact FormDPST
Switch FunctionON - OFF
Current Rating16 A
Voltage Rating AC250 VAC
Voltage Rating DC24 VDC
Mounting StylePanel
IlluminationLED
Illumination ColorBlue
Termination StyleQuick Connect Terminal
ActuatorRound
IP RatingIP64
Contact Plating-
Flammability RatingUL 04 V-0
Height46.21 mm
Housing MaterialStainless Steel
Length22 mm
Life100000 Cycles
Factory Pack Quantity10
Width16.6 mm
Unit Weight0.846575 oz
Metal Line Switches
https://www.schurter.com /PG70
MSM LA CS 19
Metal Switch, Latching Action, Switching Voltage up to 125 VDC / 250 VAC
Newly available with bright illumination
Approvals and Compliances
Description
- Switch available in version: Standard (ST), with Lettering (LE), with area
illumination (AI)
- Available with bright illumination
- Available with 12 A and 16 A switching current
- Assembly by mounting with nut and subsequent clipping of the swit-
ching element
- Equipped with flat-pin plugs to permit fast connection
Characteristics
- Housing material: high-quality stainless steel, actuator material: highly
durable ceramic
- with or without surface backlighting in different colours
- Switching voltage up to 125 VDC respectively 250 VAC, switching cur-
rent up to 16 A
- available with single-pole and double-pole switching system, switching
status is easy to discern by looking at or feeling the resting position of
the actuator
- for use in harsh environments (see technical data)
- IEC/UL 60950
References
Alternative: switch with latching function:
Alternative: Standard version
MSM 16
Alternative: double-pole switch:
MSM DP 19; MSM DP 22; MSM DP
30
Alternative: Other diameter
Weblinks
html-datasheet, General Product Information, CAD-Drawings, Product
News, Detailed request for product, Microsite, Video
Technical Data
Electrical Data
Switching Function
Number of Poles
Supply Voltage
Impulse Withstand Voltage
(ESD)
Switching Voltage
Switching Current
Rated Switching Capacity
Lifetime
N.O.
1-pole and 2-pole
24 VDC Surface backlighting
4 kV MSM LA CS ST
max. 250 VAC, 30 VDC (125 VDC at
0.5 A)
12 A AC / 16 A AC
3000 W
0.05 million actuations (250 VAC / 8
A), 0.1 million actuations (125 VDC / 0,5
A), 0.02 million actuations (250 VAC /
16 A)
< 100 mΩ (12 VDC / 1 A)
> 100 MΩ 500 VDC
10 N
5.2 mm,
0.1 million actuations
3 mm
IK 07
4.5 Nm for thread M19, 3.5 Nm for M22
12 Nm for thread M19, 16 Nm for M22
Climatical Data
Operating Temperature
Storage Temperature
IP-Protection
-20 to +85 °C
-20 to +85 °C
IP 64 Front Side Contact Area, IP
40 Front Side mechanical, IP 00 Rear
Side
24 h / 48 h / 96 h Residence Time
Contact Resistance
Insulation Resistance
Mechanical Data
Actuating Force
Actuating Travel
Lifetime
Contact Gap
Shock Protection
Tightening Torque Plastic Nut
Tightening Torque Stainless
Steel Nut
Salt Spray Test (acc. to DIN
50021-SS)
Material
Housings
Actuator (disc, outside hou-
sing)
Seal Ring
Switcher Collet
Intermediate Connector
Contact Pin Adapter
Stainless Steel
Ceramic
NBR70
PA66 (UL94-V0 related to d
1.6 mm)
PA66 (UL94-V0 related to d
1.6 mm)
PA66 (UL94-V0 related to d
1.6 mm)
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Switches
1
Please help me
Can two protection boards be used together (in parallel or in series)?...
那個誰誰誰 Motor Drive Control(Motor Control)
[Mil MYD-YA15XC-T Review] + Kernel Compilation
[i=s]This post was last edited by Popular Technology on 2021-11-28 20:26[/i]I have had the board for a while now. Today I would like to share my experience of compiling the kernel. First of all, Mir p...
流行科技 Special Edition for Assessment Centres
Please help me find out what is wrong with my program. I can't enter the interrupt mode to receive data using the usart interrupt method.
Thank you, aunties, I have been debugging for several days, I am a beginner...
PCB学徒 Programming Basics
Questions about LM3S8962 SSI communication
When using SSI communication, I use an oscilloscope to observe the pin signal. I did not observe the expected signal. What is the reason? The attached program uses the IAR5.11 development environment....
cclcxy Microcontroller MCU
Practical Analog Circuit Design Technology-Section 1
Practical Analog Circuit Design Technology-Section 1Title: Practical Analog Circuit Design Technology-Section 1Authorization: For study and research only, not for commercial useType: Circuit design in...
ghfu Analogue and Mixed Signal
I need an expert to analyze the circuit board problem. There are many problems and I don't know the reason.
The board can easily burn out various components. I don't know where the problem lies. Please analyze it. :time:...
niequanzhong Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2213  920  1947  1260  776  45  19  40  26  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号