EEWORLDEEWORLDEEWORLD

Part Number

Search

LPS-RK-300SP

Description
Electric Fuse, Time Delay Blow, 300A, 600VAC, 300VDC, 300000A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size191KB,3 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

LPS-RK-300SP Online Shopping

Suppliers Part Number Price MOQ In stock  
LPS-RK-300SP - - View Buy Now

LPS-RK-300SP Overview

Electric Fuse, Time Delay Blow, 300A, 600VAC, 300VDC, 300000A (IR), Inline/holder

LPS-RK-300SP Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
MakerCooper Industries
Reach Compliance Codeunknown
Other featuresRATED BREAKING CAPACITY AT 300 VDC: 100000 A
Fusing characteristicsTIME DELAY
body height295.4 mm
Body length or diameter59.9 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberLPS-RK
Installation featuresINLINE/HOLDER
method of packingBOX
physical size59.9mm x 295.4mm
Rated breaking capacity300000 A
Rated current300 A
Rated voltage (AC)600 V
Rated voltage (DC)300 V
GuidelineCSA; UL
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
Low Voltage, Branch Circuit Rated Fuses
Low-Peak
®
dual-element, time-delay fuses
LPN-RK_SP (250V) Class RK1
LPS-RK_SP (600V) Class RK1
Now Available
With Optional
Indication
Specifications
Description:
Current-limiting, dual-element,
time-delay fuse; 10 seconds
(minimum) at 500% rated
amps (8 seconds for 0-30A
sizes). Now available with
optional permanent indication
on select ratings (see Catalog
Numbers table).
Dimensions:
See page 11 for Class RK1 dimensions.
Construction:
Copper fuse element.
Ratings:
Volts
LPN-RK:
— 250Vac (or less)
— 125Vdc (0-60A)
— 250Vdc (70-600A)
LPS-RK:
— 600Vac (or less)
— 300Vdc
Amps —
1
10
-600A
IR — 300,000A RMS Sym.
— 100,000A dc
Agency Information:
CE, UL Listed – Special Purpose*,
Guide JFHR, File E56412, CSA Certified (200,000 AIR),
Class RK1 per CSA C22.2, No. 248.12, Class 1422-02, File
53787.
Features and Benefits
• Separate overload and short-circuit elements provide time
delay for close sizing of high inrush loads linked with K1
current-limitation and selective coordination ratio of 2:1
(within Low-Peak fuse family) prevents widespread
blackouts.
• Inventory consolidation of Class RK1, RK5 and H fuses for
reduced SKU investment and minimizing potential for
misapplying fuse.
• 300,000A RMS symmetrical interrupting rating provides
adequate ratings without obsolescence for all electrical
systems, big or small.
• Insulated end caps reduces exposure to live parts and
extends air gap to distance between blades of adjacent
mounted fuses or to housing.
Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)
LPN-RK with indication — 1066 (70-600)
LPS-RK — 1001 (0-60) and 1002 (70-600)
LPS-RK with indication — 1061 (0-60) and
1064 (70-600)
Typical Applications
• Large Distribution Switchboards
• Power Panelboards
• Motor Control Centers
• Machinery Disconnect Switches
LPN Catalog Numbers (Amps) (250Vac/125Vdc)
LPN-RK-
1
10
SP
LPN-RK-
15
100
SP
LPN-RK-
2
10
SP
LPN-RK-
3
10
SP
LPN-RK-
4
10
SP
LPN-RK-
1
2
SP
LPN-RK-
6
10
SP
LPN-RK-
8
10
SP
LPN-RK-1SP
LPN-RK-1
1
8
SP
LPN-RK-1
1
4
SP
LPN-RK-1
4
10
SP
LPN-RK-1
6
10
SP
LPN-RK-1
8
10
SP
LPN-RK-2SP
LPN-RK-2
1
4
SP
LPN-RK-2
1
2
SP
LPN-RK-2
8
10
SP
LPN-RK-3SP
LPN-RK-3
2
10
SP
LPN-RK-3
1
2
SP
LPN-RK-4SP
LPN-RK-4
1
2
SP
LPN-RK-5SP
LPN-RK-5
6
10
SP
LPN-RK-6SP
LPN-RK-6
1
4
SP
LPN-RK-8SP
LPN-RK-9SP
LPN-RK-10SP
LPN-RK-12SP
LPN-RK-15SP
LPN-RK-17
1
2
SP
LPN-RK-20SP
LPN-RK-25SP
LPN-RK-30SP
LPN-RK-35SP**
LPN-RK-40SP**
LPN-RK-45SP**
LPN-RK-50SP**
LPN-RK-60SP**
LPN-RK-70SP****
LPN-RK-80SP**
LPN-RK-90SP**
LPN-RK-100SP**
LPN-RK-110SP**
LPN-RK-125SP**
LPN-RK-150SP**
LPN-RK-175SP**
LPN-RK-200SP**
LPN-RK-225SP**
LPN-RK-250SP**
LPN-RK-300SP**
LPN-RK-350SP**
LPN-RK-400SP**
LPN-RK-450SP**
LPN-RK-500SP**
LPN-RK-600SP**
*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
**Available with optional permanent indication. To order, place “I” at end of Catalog Number.
Example: LPN-RK-35SPI.
0-60A fuses available with Nickel plate option. (Ex: LPS-RK30SPNP) 70-600A fuses available
with Tin plate option. Example: LPS-RK-100SP-TP.
LPS Catalog Numbers - (Amps) (600Vac/300Vdc)
LPS-RK-
1
10
SP
LPS-RK- ⁄
10
SP
LPS-RK-
3
10
SP
2
LPS-RK-2
1
2
SP
LPS-RK-2 ⁄
10
SP
LPS-RK-3SP
8
LPS-RK-12SP**
LPS-RK-110SP**
LPS-RK-15SP**
LPS-RK-125SP**
1
LPS-RK-17 ⁄
2
SP** LPS-RK-150SP**
LPS-RK-20SP**
LPS-RK-25SP**
LPS-RK-30SP**
LPS-RK-35SP**
LPS-RK-40SP**
LPS-RK-45SP**
LPS-RK-175SP**
LPS-RK-200SP**
LPS-RK-225SP**
LPS-RK-250SP**
LPS-RK-300SP**
LPS-RK-350SP**
LPS-RK-400SP**
LPS-RK-450SP**
LPS-RK-500SP**
LPS-RK-600SP**
LPS-RK-
4
10
SP
LPS-RK-
1
2
SP
LPS-RK-
6
10
SP
LPS-RK-
8
10
SP
LPS-RK-1SP
LPS-RK-1
1
8
SP
LPS-RK-3
2
10
SP
LPS-RK-3
1
2
SP
LPS-RK-4SP
LPS-RK-4
1
2
SP
LPS-RK-5SP
LPS-RK-5
6
10
SP
LPS-RK-1
1
4
SP LPS-RK-6SP** LPS-RK-50SP**
LPS-RK-1
4
10
SP LPS-RK-6
1
4
SP** LPS-RK-60SP**
LPS-RK-1
1
2
SP LPS-RK-7SP** LPS-RK-70SP**
LPS-RK-1
6
10
SP LPS-RK-8SP** LPS-RK-80SP**
LPS-RK-1
8
10
SP LPS-RK-9SP** LPS-RK-90SP**
LPS-RK-2
1
4
SP LPS-RK-10SP** LPS-RK-100SP**
*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
**Available with optional permanent replace fuse indication. To order, place “I” at end of
Catalog Number. Example: LPS-RK-15SPI.
Recommended Fuse Holders & Blocks For Class RK1 600V
& 250VFuses
• See page 9
16
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
16
[Preparing for the 2011 National Competition], I have the final say on my own test questions!
Original intention of the activity : Recently, I often see people asking for help on how to solve the national competition questions in the forum. In fact, just like preparing for the college entrance...
EEWORLD社区 Electronics Design Contest
A balanced MLCC solution
[i=s]This post was last edited by paulhyde on 2014-9-15 09:23[/i] [font=Verdana]An X2Y capacitor is a balanced MLCC solution with three different electrical signal paths inside and four external conne...
dtcxn Electronics Design Contest
Please help, M4F232 about timer
When I initialized the program, as long as it executed the initialization part, the program would have problems. I blocked the initialization and the program was fine. The initialization function is v...
风神懿 Microcontroller MCU
ActiveSync cannot connect when customizing your system!
I would like to ask you, I used PB to burn the system, but activesync cannot connect the board to the PC. The phenomenon is that the PC shows: Unable to recognize USB device. What do you think is the ...
missingwind Embedded System
EEWORLD University ---- Altera and Micron lead the industry - FPGA and HMC interoperability demonstration
Altera and Micron lead the industry—FPGA and HMC interoperability demonstration : https://training.eeworld.com.cn/course/2104...
chenyy FPGA/CPLD
DSP Selection
The company has a product that needs a DSP chip with CAN UART ADC and preferably LCD driver. Does anyone know what chip is available?...
wanggq DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 538  2765  613  445  1368  11  56  13  9  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号