Product datasheet
Characteristics
zckm1
limit switch body ZCKM - 1NC+1NO - snap action -
Pg11
Main
Range of product
Series name
Product or component type
Device short name
Body type
Product compatibility
Associated head
OsiSense XC
Standard format
Limit switch body
ZCKM
Fixed
XCKM
ZCKD02
ZCKD05
ZCKD06
ZCKD08
ZCKD10
ZCKD109
ZCKD15
ZCKD16
ZCKD17
ZCKD21
ZCKD219
ZCKD23
ZCKD239
ZCKD41
ZCKD59
ZCKD81
ZCKD91
ZCKD029
Metal
3 entries tapped for Pg 11 cable gland
2
1 NC + 1 NO
Snap action
1 1 position
Silver plated contacts
Body material
Cable entry
Number of poles
Contacts type and composition
Contacts operation
Number of steps
Contacts material
Complementary
Local display
Electrical connection
Positive opening
Minimum actuation speed
[Ie] rated operational current
[Ithe] conventional enclosed thermal current
[Ui] rated insulation voltage
Without
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
With
0.01 m/min
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
10 A
300 V conforming to UL 508 contact block
500 V degree of pollution 3 conforming to IEC 60947-1 contact block
300 V conforming to CSA C22.2 No 14 contact block
0.25 mOhm conforming to IEC 60255-7 category 3
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
10 A by gG cartridge fuse
5000000 cycles, DC-13 120 V, 4 W, operating rate: < 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 10 W, operating rate: < 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 7 W, operating rate: < 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
Resistance across terminals
[Uimp] rated impulse withstand voltage
Short circuit protection
Electrical durability
1/2
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Width
Height
Depth
Product weight
Terminals description ISO n°1
64 mm
64 mm
30 mm
0.21 kg
(13-14)NO
(21-22)NC
Environment
IP degree of protection
IK degree of protection
Ambient air temperature for operation
Ambient air temperature for storage
Environmental characteristic
IP65
IK08
-25...70 °C for standard environment
-40...70 °C
Standard environment
Offer Sustainability
Sustainable offer status
RoHS
Product environmental profile
Product end of life instructions
Green Premium product
Compliant - since 1007 - Schneider Electric declaration of conformity
Available
Need no specific recycling operations
2/2