EEWORLDEEWORLDEEWORLD

Part Number

Search

19101-12UL

Description
Rotary Switches Rotary Switch, Faston terminals, 12 positions, UL
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size270KB,1 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Download Datasheet Parametric Compare View All

19101-12UL Online Shopping

Suppliers Part Number Price MOQ In stock  
19101-12UL - - View Buy Now

19101-12UL Overview

Rotary Switches Rotary Switch, Faston terminals, 12 positions, UL

19101-12UL Parametric

Parameter NameAttribute value
Product CategoryRotary Switches
ManufacturerGrayhill
RoHSDetails
Number of Positions12 Position
Number of Decks1 Deck
Number of Poles per Deck1 Pole
Current Rating15 A
Voltage Rating DC120 VDC
Voltage Rating AC125 VAC
Index Angle30 deg
Contact StyleNon-Shorting
Termination StyleLug
Mounting TypePanel
Contact PlatingSilver
IlluminationNon-Illuminated
Index StopsFixed
Factory Pack Quantity25
Voltage Rating120 VAC/DC
Single Deck Rotary Switches
SERIES 19
2” Diameter, 15 Amp
FEATURES
• UL Recognized
• Rugged Construction
• Choice of Termination
DIMENSIONS
In inches (and millimeters)
Solder Lug Terminals
BUSHING KEYWAY
.066 ± .003 WIDE
(1,68 ± 0,08)
.036 ± .005 DEEP
(0,91 ± 0,13)
.344 ± .010
(8,74 ± 0,25)
1.687
± .030
(42,85
± 0,76)
DIA.
HEX MTG NUT
9/16 ± .010 (14,29 ± 0,25)
ACROSS FLATS
3/32 ± .010 (2,38 ± 0,25)
THICK
3/8-32 UNEF-2A THREAD
‘Faston’ Terminals
All dimensions not shown are the same as
the Solder Lug Terminals.
Non-Turn Washer Detail
.625 ± .010
(15,88 ± 0,25)
DIA.
.88
(22,4)
2.00
(50,8)
.025 ± .002
(0,64 ± 0,05)
.250 ± .005
(6,35 ± 0,13) DIA.
.500 ± .020
(12,7 ± 0,51)
.375 ± .020
(9,53 ± 0,51)
.219 ± .005
(5,56 ± 0,15)
.950
± .060
(24,13
± 1,52)
1.687
± .030
2.28
.88
(57,91)
(22,4)
(42,85
± 0,76)
DIA.
DIA.
.500 ± .005
(12,7 ± 1,27)
.060 ± .010
(1,52 ± 0,25)
SOLDER TERMINALS
WIRE HOLE .125 (3,18)
FOR AMP .250 SERIES
OR EQUIVALENT
WIRE HOLE .080" (2,03)
.187 ± .003
(4,75 ± 0,08)
.093 + .015/ – .000
(2,36 + 0,38/ – 0,00)
Rotary Switches
Grayhill part number and date code marked on label. Customer part number marked on request.
SPECIFICATIONS
Electrical Rating
Rated:
UL Recognition: File Number E35289
15 Amps, 120 Vac, non-inductive load.
One Amp, 120 Vdc, non-inductive load.
Additional Grayhill Rating:
7.5 Amps, 220 Vac,
non-inductive load.
This rating is based on the following criteria:
Overload—50 operations at 125% rated ac load
and 150% rated DC load.
Endurance—6000 operations at rated load
with 900 Vac dielectric strength before and
after test.
Temperature Rise—Not to exceed 30°C when
carrying rated ac load after endurance test.
Contacts will carry 20 Amps at 115 volts AC with
30°C maximum temperature rise.
Contact Resistance:
(Measured at 2 Vdc
and approximately 100 mA) for new switch
approximately 10 milliohms.
Insulation Resistance: Approximately 100,000
Mohms. Between mutually insulated parts.
Voltage Breakdown:
Approximately 2500 Vac
between mutually insulated parts.
Mounting Nut:
Brass, tin/zinc-plated or stain-
less steel.
Detent Mechanism:
Brass, silver-plated
“Faston” Terminal:
Brass, silver-plated
Solder Terminal:
Brass, silver-plated
Mounting Hardware:
One mounting nut
9
/
16
"
across flats,
3
/
32
" thick and one non-turn washer
(see detail) are supplied with each switch.
ACCESSORIES
Non-Turn Washer
Brass, tin/zinc-plated washer, detailed above
may be purchased as a separate item.
Part No. 19C1014.
ORDERING INFORMATION
Additional Characteristics
Single Pole, Single Deck:
2 to 11 positions
plus common 30° Indexing.
Contacts:
Non-shorting type
Stops:
A rivet provides the fixed stop on all
switches. Minimum number of positions is 2,
and maximum is 11. Terminal 12, the common,
is isolated from rotation.
Rotational Torque:
12 to 36 ounch-
inches on average for new switches.
Contact Force:
Approximately 12 ounces
Shaft Flat Orientation:
Opposite point of contact
(see circuit diagram).
Circuit Diagram viewed from
shaft end with switch in position #1
8
7
6
5
4
3
2
9
10
11
12 (COMMON)
1
OF BUSHING
KEYWAY
Part Numbers:
Designate as follows, using the
2 digits after the dash to indicate the number
of positions.
For Faston Terminal:
Use 19101-02UL through 19101-11UL
For Solder Terminal:
Use 19001-02UL through 19001-11UL
Specials:
Not available through Distributors. For
special shafts, bushings, etc. contact Grayhill.
Materials and Finishes
Rotor Contact:
Silver alloy
Stator Contact:
Silver alloy
Shaft:
303 Stainless steel
Stop Rivet:
Steel, tin/zinc-plated
Mounting Bushing:
Brass, tin/zinc-plated
Base and Drive Hub:
Heat resistant, electrical
grade phenolic.
Available from your local Grayhill Distributor.
For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill.
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois

19101-12UL Related Products

19101-12UL BLU1206P-1250-CB10 19101-08UL CE1206-121-G202GTS 19001-02UL CE1206-124-J101RTW 19101-10UL 19001-11UL
Description Rotary Switches Rotary Switch, Faston terminals, 12 positions, UL Fixed Resistor, Thin Film, 0.25W, 125ohm, 150V, 0.25% +/-Tol, 10ppm/Cel, 1206, Test Plugs u0026 Test Jacks 4MM (0.16) Jack For Sheathed Plug,HexNut Ceramic Capacitor, Multilayer, Ceramic, 2000V, 2% +Tol, 2% -Tol, C0G, -/+30ppm/Cel TC, 0.00012uF, 1206, Rotary Switches Rotary Switch, Solder terminals, 2 positions, UL Ceramic Capacitor, Multilayer, Ceramic, 100V, 5% +Tol, 5% -Tol, X7R, -/+15ppm/Cel TC, 0.12uF, 1206, Hook-up Wire 22AWG 19/34 PTFE 100ft SPOOL BLUE Rotary Switches 12 AMP 2P 2-11 POS
Reach Compliance Code - compliant compliant compliant compliant compliant compliant compliant
ECCN code - EAR99 EAR99 EAR99 EAR99 EAR99 EAR99 EAR99
Is it Rohs certified? - - conform to - conform to conform to conform to conform to
package instruction - - ROHS COMPLIANT , 1206 ROHS COMPLIANT , 1206 ROHS COMPLIANT ROHS COMPLIANT
JESD-609 code - - e4 - e4 e3 e4 e4
Terminal surface - - Silver (Ag) - Silver (Ag) Matte Tin (Sn) Silver (Ag) Silver (Ag)
How to see, TI official application manual - problems in the boost principle
question: Attached is the TI boost principle document . Does TI have a calculation document for the buck DC chip and the LDO principle? There are doubts about the two formulas 1. Which formula for cal...
qwqwqw2088 Analogue and Mixed Signal
[Altera SOC Experience Tour] (III) Combination of software and hardware, scancode example
[i=s]This post was last edited by Jackzhang1992 on 2015-4-17 15:14[/i] [align=center][font=宋体](III)[/font]SCAN_CODE module[/align] [align=left]This post is mainly based on the previous two posts on ps...
Jackzhang1992 FPGA/CPLD
EEWORLD University Hall - Animated demonstration of common circuits and components
Animated principle demonstration of common circuits and components : https://training.eeworld.com.cn/course/5596Animated demonstration of common circuits and components...
木犯001号 Analog electronics
Regarding the sampling rate of ad in launchpad
[align=center]In the data sheet, the explanation of ADS10SR is not very clear. Does it refer to the sampling rate? Isn't there a sampling clock ADC10CLK? And we usually use ADS10OSC, which is usually ...
一直一米 Microcontroller MCU
LCD1602+44key+UART applet
...
dizhonghua88 MCU
Please advise
1 If the CPU is connected to the outside world by multiplexing the address line and the data line, draw a structural diagram of the connection between the CPU and the memory. Explain the working princ...
cyllouis Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2581  1971  760  2820  1326  52  40  16  57  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号