Film Capacitors FKP 02 330 pF 400 VDC 2.5x7x4.6 PCM2.5
CategoryPassive components   
File Size279KB,8 Pages
ManufacturerWIMA
Websitehttps://www.wima.de/
Download Datasheet Parametric View All

FKP0G003300B00KN00 Online Shopping

Suppliers Part Number Price MOQ In stock  
FKP0G003300B00KN00 - - View Buy Now

FKP0G003300B00KN00 Overview

Film Capacitors FKP 02 330 pF 400 VDC 2.5x7x4.6 PCM2.5

FKP0G003300B00KN00 Parametric

Parameter NameAttribute value
Product CategoryFilm Capacitors
ManufacturerWIMA
Termination StyleRadial
ProductAC and Pulse Film Capacitors
DielectricPolypropylene (PP)
Capacitance330 pF
Voltage Rating AC200 VAC
Voltage Rating DC400 VDC
Tolerance10 %
Lead Spacing2.5 mm
Minimum Operating Temperature- 55 C
Maximum Operating Temperature+ 100 C
Length4.6 mm
Width2.5 mm
Height7 mm
Capacitance - nF0.33 nF
TypePolypropylene Film and Foil Capacitors
WIMA FKP 02
Polypropylene (PP) Film/Foil Capacitors for Pulse Applications in PCM 2.5 mm.
Capacitances from 100 pF to 0.01
mF.
Rated Voltages from 63 VDC to 400 VDC.
D
Special Features
˜
˜
˜
˜
˜
Pulse duty construction
PCM 2.5 mm
Close tolerances up to ±2.5%
Very low dissipation factor
Negative capacitance change
versus temperature
˜
Very low dielectric absorption
˜
According to RoHS 2011/65/EU
Electrical Data
Capacitance range:
100 pF to 0.01
mF
(E12-values on request)
Rated voltages:
63 VDC, 100 VDC, 250 VDC, 400 VDC
Capacitance tolerances:
±20%, ±10%, ±5%, ±2.5%
Operating temperature range:
–55+ C to +100+ C
Test specifications:
In accordance with IEC 60384-13
Climatic test category:
55/100/21 in accordance with IEC
Insulation resistance
at +20+ C:
5 x 10
5
(mean value: 1 x 10
6
M¸)
Measuring voltage:
U
r
= 63 V: U
test
= 50 V/1 min.
U
r
100 V: U
test
= 100 V/1 min.
Test voltage:
2 U
r
, 2 sec.
Maximum pulse rise time:
1000 V/
m
sec for pulses equal to the
rated voltage
Dielectric absorption:
0.05%
Temperature coefficient:
–200 x 10
-6
/+ C (typical)
Dissipation factors
at +20+ C: tan
d
at f
1 kHz
10 kHz
100 kHz
C
0.01
mF
4 x 10
-4
4 x 10
-4
6 x 10
-4
Typical Applications
For high frequency applications e.g.
˜
Sample and hold
˜
Timing
˜
LC-Filtering
˜
Oscillating circuits
˜
Audio equipment
Construction
Dielectric:
Polypropylene (PP) film
Capacitor electrodes:
Metal foil
Internal construction:
Voltage derating:
A voltage derating factor of 1.35 % per K
must be applied from +85+ C for DC
voltages and from +75+ C for AC
voltages.
Reliability:
Operational life
300 000 hours
Failure rate
5 fit (0.5 x U
r
and 40+ C)
Mechanical Tests
Plastic film
Metal foil electrode
Terminating wire
Packing
Available taped and reeled.
Detailed taping information and graphs
at the end of the catalogue.
Encapsulation:
Solvent-resistant, flame-retardant plastic
case with epoxy resin seal, UL 94 V-0
Terminations:
Tinned wire.
Marking:
Colour: Red. Marking: Black.
Epoxy resin seal: Yellow
Pull test on pins:
10 N in direction of pins according to
IEC 60068-2-21
Vibration:
6 hours at 10 ... 2000 Hz and 0.75 mm
displacement amplitude or 10 g in
accordance with IEC 60068-2-6
Low air density:
1kPa = 10 mbar in accordance with
IEC 60068-2-13
Bump test:
4000 bumps at 390 m/sec
2
in
accordance with IEC 60068-2-29
For further details and graphs please
refer to Technical Information.
04.16
27
EEWORLD University Hall----Black technology probe: know the current size by touching it (English, foreign netizens' evaluation)
Black technology probe: Know the current size by just touching it (English, foreign netizens’ reviews) : https://training.eeworld.com.cn/course/5125...
nmg Test/Measurement
Has anyone ever used the CC3200 module as a slave for SPI communication?
Has anyone ever used the CC3200 module as a slave for SPI communication?...
zlambert0205 Wireless Connectivity
Study on digital filter to filter out power frequency and harmonic interference in electronic measurement system
Abstract: In electronic measurement, power frequency is one of the main sources of noise interference. If it is not filtered out, it will greatly affect the measurement accuracy. The traditional analo...
fighting Test/Measurement
How to enable the device's code scanning function when developing software for MOTOROLA MC1000 using VS2008
How to enable the code scanning function of the device when developing software for MOTOROLA MC1000 with VS2008? I recently developed a WINDOWS CE .NET 4.2 program with VS.NET2008 and it runs normally...
eagletie Embedded System
Detailed explanation of Zigbee networking principle
Building a complete Zigbee mesh network includes two steps: network initialization and node joining the network. Node joining the network includes two steps: joining the network by connecting to the c...
灞波儿奔 Wireless Connectivity
ZigBee Help Post
Hello everyone, I would like to ask how to solve the problem that the network address of the ZigBee node changes after powering off and then back on. I am a novice, please explain in detail...
mgf_xuexi RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1614  1781  2407  2171  2153  33  36  49  44  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号