EEWORLDEEWORLDEEWORLD

Part Number

Search

MI-P7V1-IXZ

Description
Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs
File Size129KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

MI-P7V1-IXZ Overview

Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs

MI - MegaMod
TM
Family
Military Chassis Mount DC-DC Converters 10 to 300W
Single, Dual, Triple Outputs
Features
Inputs:
28, 155, 165 and 270Vdc
Any output: 2 to 48Vdc
Up to 13.5W/in
3
High efficiency
Size — 1- up half-size: 2.58" x 2.5" x 0.62"
(65,5 x 63,5 x 15,7mm)
Size — 1- up full-size: 4.9" x 2.5" x 0.62"
(124,5 x 63,5 x 15,7mm)
Size — 2- up half-size: 2.58" x 4.9" x 0.62"
(65,5 x 124,5 x 15,7mm)
Size — 2- up full-size: 4.9" x 4.9" x 0.62"
(124,5 x 124,5 x 15,7mm)
Size — 3- up half-size: 2.58" x 7.3" x 0.62"
(65,5 x 185,4 x 15,7mm)
Size — 3- up full-size: 4.9" x 7.3" x 0.62"
(124,5 x 185,4 x 15,7mm)
Product Highlights
Vicor’s MI-MegaMod family
of single, dual, and triple output
DC-DC converters provide power
system designers with cost-
effective, high-performance, off-
the-shelf solutions to applications
that might otherwise require a
custom supply.
Incorporating standard MI-200
or MI-J00 family converters in
rugged, chassis mount packages,
MegaMods can be ordered with
single, dual, or triple outputs,
having a combined output power
of up to 300W. Totally isolated
outputs eliminate efficiency
penalties and output interaction
problems.
Remote sense
ZVS/ZCS power architecture
Low noise FM control
Configuration Chart
Full-Size MegaMods
Single Output
MI-L
MI-M
MI-N
Dual Output
MI-P
MI-Q
Triple Output
MI-R
Number of
Modules
1
2
3
2
3
3
50 – 100W
150 – 200W
300W
100 – 200W
200 – 300W
150 – 300W
4.9" x 2.5" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 7.3" x 0.62"
Half-Size MegaMods
Single Output
MI-LJ
Dual Output
MI-PJ
Triple Output
MI-RJ
10 – 50W
20 – 100W
30 – 150W
2.58" x 2.5" x 0.62"
2.58" x 4.9" x 0.62"
2.58" x 7.3" x 0.62"
1
2
3
Input Voltage
Nominal Range Transient
2 =28Vdc
5 =155Vdc
6 =270Vdc
7 =165Vdc
18 –
60V
100 – 210V 230V
125 – 400V
(2)
475V
100 – 310V
(3)
50V
(1)
Output Voltage
Z = 2V
Y = 3.3V
0 = 5V
X = 5.2V
W= 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
Product Grade
Full-Size
I = –40°C to +85°C
M = –55°C to +85°C
Half-Size
I = –40°C to +100°C
M = –55°C to +100°C
Output Power/Current
Full-Size
Half-Size
≥5V
<5V
≥5V
<5V
Y
X
W
V
= 50W 10A A = 10W —
= 75W 15A Z = 25W 5A
= 100W 20A Y = 50W 10A
= — 30A
Output Power/Current
≥5V
<5V
V
U
S
=
=
=
150W
200W
30A
60A
Output Power/Current
≥5V
<5V
S
P
=
=
300W
90A
(1)
(2)
(3)
16V operation at 75% load.
These units rated at 75% load from 125 – 150Vin: Full-size – 5Vout @ 100W; 2Vout and 3.3Vout @ 30A
Half-Size – 5Vout @ 50W; 2V and 3.3V @ 10A.
For use with Vicor’s MI-AIM
MI-MegaMod 10/02
1 of 4
[EEWORLD 14th Community Celebrity] The Celebrity of April 2010 is freshly announced!
"A year's plan begins in spring." At the beginning, there is plenty of time and hope. Spring is like a newborn baby, new from head to toe, and growing. Spring is like a little girl, dressed up, smilin...
EEWORLD社区 Suggestions & Announcements
Today I have drawn the schematic diagram of the AVR board, but I have not drawn the power supply part. Which power supply do you use? USB or independent
I took a screenshot but it's not very clear. Can you tell me how to provide power better? [img]http://group.ednchina.com/Upload/2007/10/13/af31f594-7f7c-47f3-bf97-d9a3806b4305.JPG[/img]...
fjqiuh Microchip MCU
EEWORLD University--ADI online seminar to understand data converter errors and parameters
ADI online seminar to understand data converter errors and parameters : https://training.eeworld.com.cn/course/4791?Understand data converter errors and parameters...
JFET Analog electronics
[EasyARM-RT1052 Review] + Serial port idle reception to implement modbus host
[font=微软雅黑][size=4]The board does not have a 485 interface, so it can only be simulated through the serial port. The serial port resources are relatively rich, and the board has reserved several chann...
ID.LODA NXP MCU
Via Design
In ordinary PCB design, for 1-4 layer PCB design, it is generally better to use 0.36mm/0.16mm/1.02mm (drilling/pad/power isolation area) vias, but the problem is that such vias are too small and canno...
ckx提问 PCB Design
Command line parameters argc, argv in C language
main( int argc, char ** argv ) argv: pointer to pointer argc: integer char **argv or char *argv[] or char argv[][] In order to illustrate the meaning of these two parameters vividly, let us first use ...
jxb01033016 Programming Basics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2327  2167  1770  1977  888  47  44  36  40  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号