Angle Bracket, Angle Bracket Tapped, Without Angle Bracket
38330, 38336
p. 2-3
38540
p. 16-17
Shallow Bracket
38330
38542
Deep Bracket
38330, 38336
38540
p. 4-5
p. 18-19
p. 6-7
p. 20-21
Cable Mount Plugs and Sockets
Cable Clamp End
38331, 38336
38541
p. 8-9
p. 22-23
Cable Clamp Top, Cable Clamp Top with Keeper, Cable Clamp Top with Latch
38330, 38331, 38336
p. 10-11
p. 24-25
38541
Flared Hole End
38330, 38336
38540
Flared Hole Top
38330, 38331, 38336
38540
p. 12-13
p. 26-27
p. 14-15
p. 28-29
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 2 to 33 circuits
n
Robust blade contacts resist damage from
improper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated for
full current load
n
Extra long pre-grounding contact engages
before any other contacts for greater safety.
Electrical
Voltage: 250V
Maximum Current:
10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330, 38336
Angled Bracket (AB)
Angle Bracket Tapped (ABT)
Less Angle Bracket (LAB)
Physical
Base Insulator: High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Fig. D
Diameter
.156”
(3,96)
Reference Information
UL :
CSA:
File E34763
File 22156
.66”
(16,8)
38330-XX02
Diameter
.156”
(3,96)
.020”
(0,51)
Fig. E
.031”
(0,80)
Diameter
.156”
(3,96)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
.38”
(9,65)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.045” square
(1,14)
.97”
(24,6)
.078”
(1,98)
.44”
(11,1)
Diameter
.672”
(17,1)
38330-XX03-15
S
1
Quick Connect
.22”
(5,59)
Diameter
.156”
(3,96)
.06”
(1,59)
.44”
(11,1)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
Fig. F
Fig. G
Diameter
.156”
(3,96)
S Solder Eye (Standard)
.22”
(5,59)
1.015”
(25,8)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
1.38”
(34,9)
38330-XX18-33
.06”
(1,59)
.032”
(0,81)
Diameter
.156”
(3,96)
1.375”
(34,9)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Diameter
.156”
(3,96)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
3330 and in position 17 for No. 3333. * Indicates location of pre-grounding contact. † Pregrounding contact is standard.
38330-XX02
38330-XX03
38330-XX04
38330-XX06
38336-8XXX
38330-XX08
38330-XX10
38330-XX12
38330-XX15 to 38330-XX21
38330-XX24 to 38330-XX30
38330-XX33
ORDERING INFORMATION AND DIMENSIONS
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
38330, 38336
Part #
in
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
0.66
1.00
0.75
1.00
1.00
1.25
1.56
1.25
1.63
1.94
2.25
2.56
2.88
3.19
3.50
T
mm
16,7
25,4
19,1
25,4
25,4
31,8
39,7
31,8
41,3
49,2
57,2
65,1
73,0
81,0
88,9
U
in
--
.44
.69
.69
.69
.69
.69
.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
V
mm
--
11,1
17,5
17,5
17,5
17,5
17,5
23,8
25,4
25,4
25,4
25,4
25,4
25,4
25,4
Part #
mm
32,1
27,0
33,3
33,3
33,3
33,3
33,3
39,7
42,9
42,9
42,9
42,9
42,9
42,9
42,9
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
Fig. #
in
D
E
F
E
E
F
F
F
F
G
G
G
G
G
G
.969
.750
1.000
1.000
1.000
1.000
1.000
1.250
1.375
1.250
.938
1.250
1.562
1.875
2.188
A
mm
24,6
19,1
25,4
25,4
25,4
25,4
25,4
31,8
34,9
31,8
23,8
31,8
39,7
47,6
55,6
B
in
--
1.016
.781
1.031
1.031
1.281
1.578
1.266
1.640
1.953
2.265
2.578
2.890
3.203
3.515
C
mm
--
25,8
19,8
26,2
26,2
32,5
40,1
32,2
41,7
49,6
57,5
65,5
73,4
81,4
89,3
in
1.27
1.06
1.31
1.31
1.31
1.31
1.31
1.56
1.69
1.69
1.69
1.69
1.69
1.69
1.69
in
--
.453
.719
.719
.719
.719
.719
.953
1.016
--
--
--
--
--
--
mm
--
11,5
18,3
18,3
18,3
18,3
18,3
24,2
25,8
--
--
--
--
--
--
PLUGS
Angle Bracket (-AB)
Order #
38330-0102
38330-0103
38330-0104
38330-0106
38336-8001
38330-0108
38330-0110
38330-0112
38330-0115
38330-0118
38330-0121
38330-0124
38330-0127
38330-0130
38330-0133
Engineering #
P-3302-AB
P-3303-AB
P-3304-AB
P-3306-AB
P-3306-8-AB
P-3308-AB
P-3310-AB
P-3312-AB
P-3315-AB
P-3318-AB
P-3321-AB
P-3324-AB
P-3327-AB
P-3330-AB
P-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1502
38330-1503
38330-1504
38330-1506
38336-8015
38330-1508
38330-1510
38330-1512
38330-1515
38330-1518
38330-1521
38330-1524
38330-1527
38330-1530
38330-1533
Engineering #
P-3302-ABT
P-3303-ABT
P-3304-ABT
P-3306-ABT
P-3306-8-ABT
P-3308-ABT
P-3310-ABT
P-3312-ABT
P-3315-ABT
P-3318-ABT
P-3321-ABT
P-3324-ABT
P-3327-ABT
P-3330-ABT
P-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2202
38330-2203
38330-2204
38330-2206
38336-8022
38330-2208
38330-2210
38330-2212
38330-2215
38330-2218
38330-2221
38330-2224
38330-2227
38330-2230
38330-2233
Engineering #
P-3302-LAB
P-3303-LAB
P-3304-LAB
P-3306-LAB
P-3306-8-LAB
P-3308-LAB
P-3310-LAB
P-3312-LAB
P-3315-LAB
P-3318-LAB
P-3321-LAB
P-3324-LAB
P-3327-LAB
P-3330-LAB
P-3333-LAB
SOCKETS
Angle Bracket (-AB)
Order #
38330-0502
38330-0503
38330-0504
38330-0506
38336-8005
38330-0508
38330-0510
38330-0512
38330-0515
38330-0518
38330-0521
38330-0524
38330-0527
38330-0530
38330-0533
Engineering #
S-3302-AB
S-3303-AB
S-3304-AB
S-3306-AB
S-3306-8-AB
S-3308-AB
S-3310-AB
S-3312-AB
S-3315-AB
S-3318-AB
S-3321-AB
S-3324-AB
S-3327-AB
S-3330-AB
S-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1902
38330-1903
38330-1904
38330-1906
38336-8019
38330-1908
38330-1910
38330-1912
38330-1915
38330-1918
38330-1921
38330-1924
38330-1927
38330-1930
38330-1933
Engineering #
S-3302-ABT
S-3303-ABT
S-3304-ABT
S-3306-ABT
S-3306-8-ABT
S-3308-ABT
S-3310-ABT
S-3312-ABT
S-3315-ABT
S-3318-ABT
S-3321-ABT
S-3324-ABT
S-3327-ABT
S-3330-ABT
S-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2602
38330-2603
38330-2604
38330-2606
38336-8026
38330-2608
38330-2610
38330-2612
38330-2615
38330-2618
38330-2621
38330-2624
38330-2627
38330-2630
38330-2633
Engineering #
S-3302-LAB
S-3303-LAB
S-3304-LAB
S-3306-LAB
S-3306-8-LAB
S-3308-LAB
S-3310-LAB
S-3312-LAB
S-3315-LAB
S-3318-LAB
S-3321-LAB
S-3324-LAB
S-3327-LAB
S-3330-LAB
S-3333-LAB
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 15 to 33 circuits
n
Robust blade contacts resist damage
fromimproper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated
for full current load
n
Extra long pre-grounding contact
engages before any other contacts for
greater safety.
Electrical
Voltage: 250V
Maximum Current: 10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330
Shallow Bracket (SB)
Physical
Base Insulator:High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Reference Information
UL :
CSA:
File E34763
File 22156
.032”
(0,81)
Fig. K
1.08”
(27.4)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.38”
(9,65)
.045” square
(1,14)
1.38”
(34.9)
.44”
(11,1)
Diameter
.187”
(4,75)
S
1
Quick Connect
.22”
(5,59)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
S Solder Eye (Standard)
.22”
(5,59)
Diameter
.190”
(4.83)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
RISC (Reduced Instruction Set Computer) and CISC (Complex Instruction Set Computer) are two architectures of current CPUs. The difference between them lies in different CPU design concepts and methods...
Watch the video of the 430FR5739 series. If the temperature is too high during manual soldering, will it cause data loss, shorten the effective time, or damage the device and make it unusable?
The vid...
I want to use the USB OTG of STM32F105VC and plan to use the master mode. When initializing USBDM and USBDP , what mode should I choose for GPIO_InitStructure.GPIO_Mode?typedef enum{ GPIO_Mode_AIN = 0...
I have a question. I have an amplifier with an output of 100W, but the output S22 is a little bit below the standard, mainly because the bandwidth is too large. I tried 3dB attenuation with resistors ...
[i=s]This post was last edited by chenbingjy on 2016-9-19 13:28[/i] [color=#333333]There is a project file list as follows. There are 5 files in the project. In the add directory, there are add_int.c ...
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
Today's security industry has entered the era of massive networking. Many enterprises, especially financial institutions, have established multi-level video surveillance networking platforms. Lever...[Details]
The automotive industry in 2025 is undergoing a thorough intelligent reshuffle.
Geely wants to make changes in the field of AI cockpits: in the future, there will be no traditional smart...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
Compared to cloud databases, minicomputers are purpose-built for decentralized, rugged computing at the edge of the network. By moving applications, analytics, and processing services closer to the...[Details]
For new energy vehicles, the importance of batteries is unquestionable. Not only does it determine the performance of the vehicle, but the battery density also has a great relationship with the veh...[Details]
In camera and display systems, the demand for high-performance and low-power data interfaces is driving continuous technological evolution. The evolution of MIPI D-PHY and MIPI C-PHY clearly ...[Details]
The power transmission system between a car's engine and drive wheels is called its drivetrain. It ensures the necessary traction and speed under various driving conditions, and coordinates these t...[Details]
In the wave of electrification and intelligence in the automotive industry, the E/E architecture is transitioning from distributed to domain control and then to regional architecture.
Th...[Details]
In a previous article, we introduced
the origin of
AVTP
and the meaning of the various header fields when using it to transmit audio. This article will explain the meaning and constraints of...[Details]
Amid the rapid advancement of automotive intelligence, on-board storage has become a thorny bottleneck restricting the "large-scale popularization" of advanced assisted driving.
On the o...[Details]
STM8S compilation error unable to allocate space for sections/blocks with a total # Welcome to use Markdown editor
I've encountered many strange issues while developing with IAR for STM8, all ...[Details]
The motors on some production machinery are required to run for a period of time and then stop for a period of time, which is called intermittent operation. As shown in the figure below, this funct...[Details]
The functions are still useless. When will it be able to be clearly distinguished from smartphones?
Most consumers categorize their smartwatch purchases as a desire to try something new. A sig...[Details]