EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/S-8101-11

Description
Barrier Strip Terminal Block, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size78KB,1 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK/S-8101-11 Overview

Barrier Strip Terminal Block, 1 Row(s), 1 Deck(s)

BK/S-8101-11 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresTHERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial number8100
Installation typeDIN RAIL
Number of layers1
Rows1
Number of channels11
Rated voltage300 V
safety certificateUL; CSA
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Base Number Matches1
FUSE BLOCKS FOR MIDGET
AND ELECTRONIC FUSES
Catalog Number 3835 Series
MULTIPLE POLE FUSEBLOCKS:
3835 Series:
For 13/32" x 1-1/2" (10.3mm x 28.1mm) fuses.
Ampere Rating:
30 Amps
Voltage Rating:
250 volts
Material:
Silver-plated, beryllium copper clips.
No side barriers. Screw terminals.
Phenolic base.
Catalog Number 8000 Series
BOLT-IN AND SNAP-IN MOUNTING FUSEBLOCKS:
For 1/4" x 1-1/4" fuses.
Blocks are molded flame retarded
thermopastic. Clips are spring-bronze.
Voltage Rating:
300V
Agency Approvals:
UL Recognized under Components Program; File E14853A,
Guide IZLT2
CSA Certified Class 6225-01, File 47235
Anti-Rotation Pin:
Single-pole blocks may be ordered
without the antirotational pin simply
by adding an “X” to the number of
poles (Example: BK/S-8001-1X).
Carton Quantity:
10; shelf package: 100.
Bulk Carton:
Single-pole and 2-pole fuse blocks
— 1,000; Multiple-pole fuse blocks
— 3-8 pole: 200; 9-12 pole: 50.
When ordering bulk quantities, prefix “BK/” to catalog
number: (Example: BK/S-8001-1SNP).
Bolt-in Mounting
Series
8000
8100
Terminal
Solder
3/16" Quick
Connect
1/4" Quick
Connect
Screw
Amperes
UL 25A
CSA 21A
UL 20A
CSA 16A
UL 20A
CSA 16A
UL 30A
CSA 10A
Amperes
UL 25A
CSA 21A
UL 20A
CSA 16A
UL 20A
CSA 16A
Angle
40°
40°
40°
Side
*Basic
Cat. No.
S-8001-
S-8002-
S-8101-
S-8102-
S-8201-
S-8202-
S-8203-
S-8301-
Poles
(Suffix)
Construction:
Catalog Data
Catalog
Number
3835-1
3835-2
3835-3
3835-4
3835-5
3835-6
3835-7
3835-8
3835-9
3835-10
3835-12
No. of
Poles
1
2
3
4
5
6
7
8
9
10
12
Base Length
Inches
27/32
1-13/16
2-25/32
3-3/4
4-23/32
5-11/16
6-21/32
7-5/8
8-19/32
9-9/16
11-1/2
mm
21.4
46.0
70.6
95.2
119.9
144.5
169.0
193.7
218.8
242.9
292.1
*Base width — 2-3/4" (69.9mm)
1 - 12
2.75"
(69.9mm)
8200
8301
1.0"
(25.4mm)
Snap-in Mounting
(Poles available in single-pole only)
0.25"
(6.4mm)
Series
8000
8100
Terminal
Solder
3/16" Quick
Connect
1/4" Quick
Connect
Angle
40°
40°
Side
Cat. No.
S-8001-1-SNP
S-8002-1-SNP
S-8101-1-SNP
S-8102-1-SNP
S-8201-1-SNP
S-8203-1-SNP
NOTE:
Mounting screw hole diameter is 0.148" (3.7mm).
Countersink, 0.313" (7.9mm). Max. Mounting scrw No. 6.
8200
Catalog Code
BK/
Prefix for Bulk Packing
Series 8000 Produce Line
Type Terminal
“0”-Solder; “1”-3/16"
Quick Connect; “2”-1/4"
Quick Connect; “3”-Screw
Terminal Angle
“01”-straight (0‚); “02”-40°; “03”-side*
Number of Poles (01-12)
S-8
0
00
-00
155
Design of Single Chip Microcomputer Simulator Based on SST89C54/58
1 OverviewSST89C54/58 (abbreviated as 89C54/58) is a multi-purpose 51 series microcontroller launched by SST Corporation of the United States. It integrates 20 kB/36 kB SuperFlash E'PROM program memor...
fighting MCU
[ESP32-Audio-Kit Audio Development Board Review] 4. MIC Input Exploration + Help
[i=s]This post was last edited by wo4fisher on 2021-9-28 16:15[/i]After completing the "play-mp3-control" routine in the previous article, I thought the rest of the journey would be much smoother, but...
wo4fisher RF/Wirelessly
The serial port bit error rate is very high
When I use the serial port (USB to transfer) to connect to the development board, there is always a high error rate when inputting commands. That is, you clearly input Ls, but it becomes Lc on the dev...
liukaiyue Embedded System
China Electronics Engineer Salary Survey
[size=4] [b]2006 Electronic Industry Salary Survey[/b][/size] Since 2002, the "China Electronic Engineer Salary Survey" has been held for three consecutive years. This year, a total of 2,287 electroni...
lijiaoeeworld Talking about work
Why does DirectDrawCreate return an error when using DirectDraw in WinCE?
{ return FALSE; } else {...
zdhwcf Embedded System
Win CE 5.0 dial-up component
In Win CE 5.0 system, which components can be added to achieve the setting of detailed parameters of GPRS dial-up, including general items, modem and proxy server settings. Please help!...
yqivy Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 831  116  541  1222  614  17  3  11  25  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号