EEWORLDEEWORLDEEWORLD

Part Number

Search

MI-P5TP-IYY

Description
Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs
File Size129KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

MI-P5TP-IYY Overview

Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs

MI - MegaMod
TM
Family
Military Chassis Mount DC-DC Converters 10 to 300W
Single, Dual, Triple Outputs
Features
Inputs:
28, 155, 165 and 270Vdc
Any output: 2 to 48Vdc
Up to 13.5W/in
3
High efficiency
Size — 1- up half-size: 2.58" x 2.5" x 0.62"
(65,5 x 63,5 x 15,7mm)
Size — 1- up full-size: 4.9" x 2.5" x 0.62"
(124,5 x 63,5 x 15,7mm)
Size — 2- up half-size: 2.58" x 4.9" x 0.62"
(65,5 x 124,5 x 15,7mm)
Size — 2- up full-size: 4.9" x 4.9" x 0.62"
(124,5 x 124,5 x 15,7mm)
Size — 3- up half-size: 2.58" x 7.3" x 0.62"
(65,5 x 185,4 x 15,7mm)
Size — 3- up full-size: 4.9" x 7.3" x 0.62"
(124,5 x 185,4 x 15,7mm)
Product Highlights
Vicor’s MI-MegaMod family
of single, dual, and triple output
DC-DC converters provide power
system designers with cost-
effective, high-performance, off-
the-shelf solutions to applications
that might otherwise require a
custom supply.
Incorporating standard MI-200
or MI-J00 family converters in
rugged, chassis mount packages,
MegaMods can be ordered with
single, dual, or triple outputs,
having a combined output power
of up to 300W. Totally isolated
outputs eliminate efficiency
penalties and output interaction
problems.
Remote sense
ZVS/ZCS power architecture
Low noise FM control
Configuration Chart
Full-Size MegaMods
Single Output
MI-L
MI-M
MI-N
Dual Output
MI-P
MI-Q
Triple Output
MI-R
Number of
Modules
1
2
3
2
3
3
50 – 100W
150 – 200W
300W
100 – 200W
200 – 300W
150 – 300W
4.9" x 2.5" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 7.3" x 0.62"
Half-Size MegaMods
Single Output
MI-LJ
Dual Output
MI-PJ
Triple Output
MI-RJ
10 – 50W
20 – 100W
30 – 150W
2.58" x 2.5" x 0.62"
2.58" x 4.9" x 0.62"
2.58" x 7.3" x 0.62"
1
2
3
Input Voltage
Nominal Range Transient
2 =28Vdc
5 =155Vdc
6 =270Vdc
7 =165Vdc
18 –
60V
100 – 210V 230V
125 – 400V
(2)
475V
100 – 310V
(3)
50V
(1)
Output Voltage
Z = 2V
Y = 3.3V
0 = 5V
X = 5.2V
W= 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
Product Grade
Full-Size
I = –40°C to +85°C
M = –55°C to +85°C
Half-Size
I = –40°C to +100°C
M = –55°C to +100°C
Output Power/Current
Full-Size
Half-Size
≥5V
<5V
≥5V
<5V
Y
X
W
V
= 50W 10A A = 10W —
= 75W 15A Z = 25W 5A
= 100W 20A Y = 50W 10A
= — 30A
Output Power/Current
≥5V
<5V
V
U
S
=
=
=
150W
200W
30A
60A
Output Power/Current
≥5V
<5V
S
P
=
=
300W
90A
(1)
(2)
(3)
16V operation at 75% load.
These units rated at 75% load from 125 – 150Vin: Full-size – 5Vout @ 100W; 2Vout and 3.3Vout @ 30A
Half-Size – 5Vout @ 50W; 2V and 3.3V @ 10A.
For use with Vicor’s MI-AIM
MI-MegaMod 10/02
1 of 4
I bought the Feiling board OK6410-A 2 months ago.
For more information, please contact QQ: 348075293 Mobile: 13732189922[local]1[/local]Reference price: 550 (including emulator, serial port adapter, and serial port expansion. If these accessories are...
BBNets Buy&Sell
I tried online payment today~~
I happened to have two numbers that needed to be recharged, one from China Unicom and one from China Mobile. I logged into China Unicom's website, entered my number, and recharged directly. The basic ...
幸福的娃 RF/Wirelessly
[Liquid Level Sensor Evaluation] Re-understanding of Capacitive-Contactless Liquid Level Sensor
[i=s]This post was last edited by jinglixixi on 2021-9-17 11:29[/i]Previously, we have introduced the detection effect of capacitive-contactless liquid level sensors on different container materials. ...
jinglixixi Sensor
What are your plans for learning MSP430 in the new year?
The New Year holiday is over.People are starting to go back to work or school.It's time to return to my usual busy work and life.During the Spring Festival,We are all busy eating, drinking and having ...
wstt Microcontroller MCU
EEWORLD University Hall----Industrial Application of TI Sensors
Industrial Applications of TI Sensors : https://training.eeworld.com.cn/course/3670...
wanglan123 Talking
TVS tube selection calculation, the dissipated power of the TVS component is greater than the waveform power according to this standard? Here is the test waveform...
TVS tube selection calculation, the dissipated power of the TVS component is greater than the waveform power according to this standard? I don't understand the power calculation of the test waveform h...
QWE4562009 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 651  269  1382  2738  1214  14  6  28  56  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号