EEWORLDEEWORLDEEWORLD

Part Number

Search

MI-P54V-IXA

Description
Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs
File Size129KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

MI-P54V-IXA Overview

Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs

MI - MegaMod
TM
Family
Military Chassis Mount DC-DC Converters 10 to 300W
Single, Dual, Triple Outputs
Features
Inputs:
28, 155, 165 and 270Vdc
Any output: 2 to 48Vdc
Up to 13.5W/in
3
High efficiency
Size — 1- up half-size: 2.58" x 2.5" x 0.62"
(65,5 x 63,5 x 15,7mm)
Size — 1- up full-size: 4.9" x 2.5" x 0.62"
(124,5 x 63,5 x 15,7mm)
Size — 2- up half-size: 2.58" x 4.9" x 0.62"
(65,5 x 124,5 x 15,7mm)
Size — 2- up full-size: 4.9" x 4.9" x 0.62"
(124,5 x 124,5 x 15,7mm)
Size — 3- up half-size: 2.58" x 7.3" x 0.62"
(65,5 x 185,4 x 15,7mm)
Size — 3- up full-size: 4.9" x 7.3" x 0.62"
(124,5 x 185,4 x 15,7mm)
Product Highlights
Vicor’s MI-MegaMod family
of single, dual, and triple output
DC-DC converters provide power
system designers with cost-
effective, high-performance, off-
the-shelf solutions to applications
that might otherwise require a
custom supply.
Incorporating standard MI-200
or MI-J00 family converters in
rugged, chassis mount packages,
MegaMods can be ordered with
single, dual, or triple outputs,
having a combined output power
of up to 300W. Totally isolated
outputs eliminate efficiency
penalties and output interaction
problems.
Remote sense
ZVS/ZCS power architecture
Low noise FM control
Configuration Chart
Full-Size MegaMods
Single Output
MI-L
MI-M
MI-N
Dual Output
MI-P
MI-Q
Triple Output
MI-R
Number of
Modules
1
2
3
2
3
3
50 – 100W
150 – 200W
300W
100 – 200W
200 – 300W
150 – 300W
4.9" x 2.5" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 7.3" x 0.62"
Half-Size MegaMods
Single Output
MI-LJ
Dual Output
MI-PJ
Triple Output
MI-RJ
10 – 50W
20 – 100W
30 – 150W
2.58" x 2.5" x 0.62"
2.58" x 4.9" x 0.62"
2.58" x 7.3" x 0.62"
1
2
3
Input Voltage
Nominal Range Transient
2 =28Vdc
5 =155Vdc
6 =270Vdc
7 =165Vdc
18 –
60V
100 – 210V 230V
125 – 400V
(2)
475V
100 – 310V
(3)
50V
(1)
Output Voltage
Z = 2V
Y = 3.3V
0 = 5V
X = 5.2V
W= 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
Product Grade
Full-Size
I = –40°C to +85°C
M = –55°C to +85°C
Half-Size
I = –40°C to +100°C
M = –55°C to +100°C
Output Power/Current
Full-Size
Half-Size
≥5V
<5V
≥5V
<5V
Y
X
W
V
= 50W 10A A = 10W —
= 75W 15A Z = 25W 5A
= 100W 20A Y = 50W 10A
= — 30A
Output Power/Current
≥5V
<5V
V
U
S
=
=
=
150W
200W
30A
60A
Output Power/Current
≥5V
<5V
S
P
=
=
300W
90A
(1)
(2)
(3)
16V operation at 75% load.
These units rated at 75% load from 125 – 150Vin: Full-size – 5Vout @ 100W; 2Vout and 3.3Vout @ 30A
Half-Size – 5Vout @ 50W; 2V and 3.3V @ 10A.
For use with Vicor’s MI-AIM
MI-MegaMod 10/02
1 of 4
Plastic Circular Medical Connectors Selection Guide
[font=微软雅黑][size=3][/size][/font] [font=微软雅黑][size=3]MediSpec Medical Plastic Circular (MPC) Connectors and Cable Assemblies meet stringent industry standards and provide superior performance at a fra...
橙色凯 Medical Electronics
Seek innovative CDs from Ruitai
Today I got a set of ICEK-5100USB V2.0A emulator and an experiment box with ICETEK-F2812-A, but I don’t have the CD and other materials. I hope friends who have relevant materials can send a copy to 3...
ailover2001 DSP and ARM Processors
Problem with HalAdcRead() function
Hello everyone, I have a question for you. I called HalAdcRead() function twice in timer interrupt, but found that only the first time can return the value normally, and the second time can not return...
wangcharon RF/Wirelessly
Design Guide for RF Impedance Matching: Playing with the Smith Chart
Abstract: This article uses the Smith chart as a design guide for RF impedance matching. Examples of plotting reflection coefficient, impedance, and admittance are given, as well as an example of plot...
toothache RF/Wirelessly
About Reset
Today I read the information and saw Synchronized Asynchronous Reset. The specific code is as follows...
xieqiang FPGA/CPLD
What are the advantages of domestic brands of test and measurement instruments?
Have you used domestic test and measurement instruments? Tell us about your experience. Although like many other products, domestic products are not as good as those of big brands such as Tektronix an...
向农 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2165  2278  2262  2168  1496  44  46  31  36  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号