pHE844
• Emi suppressor, class x1, metallized polypropylene
• 0.1 – 2.2 µf, 440 vac/480 vac, +105°c
L
RoHS
Compliant
B
tYpiCaL appLiCations
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
Not for use in series with the mains.
See www.kemet.com for more information.
ConstRuCtion
Series winding of metallized polypropylene.
Encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
p
∅
d
H
0.5
l
tECHniCaL data
rated voltage
capacitance range
capacitance tolerance
temperature range
climatic category
approvals
dissipation factor
440 VAC 50/60 Hz (ENEC)
480 VAC 50/60 Hz (UL, CSA)
0.1 – 2.2 µF
± 20% standard, ± 10% option
–40 to +105°C
40/105/56/B
ENEC, UL, cUL
Maximum values at +23°C
C
≤
0.1 µF 0.1µF < C
≤
1 µF
1 kHz
0.1%
0.1%
10 kHz
0.2%
0.4%
100 kHz
0.6%
–
C > 1 µF
0.1%
0.8%
–
p
b
d
0.8
0.8
1.0
std l
6
6
6
max l
30
30
30
b
±0.4
±0.4
±0.7
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
Tolerance in lead length
+0
< 30 mm
–1
mm
30 mm
+5
–0
mm
test voltage between
terminals
The 100% screening factory test is carried out at 3000
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Tabulated self-resonance frequencies f
0
refer to 5 mm
lead length.
C
≤
0.33 µF:
≥
30 000 MΩ
C > 0.33 µF:
≥
10 000 s
Recommended voltage:
≤1000VDC
resonance frequency
insulation resistance
in dc application
EnViRonmEntaL tEst data
Endurance
EN/IEC 60384-14:2005
1.25 x U
R
VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s
2
1000 bumps at
390 m/s
2
Upper and lower rated
temperature 5 cycles
No visible damage
No open or short circuit
No visible damage
No open or short circuit
No visible damage
vibration
Bump
change of temperature
active flammability
Passive flammability
humidity
IEC 60068–2–6
Test Fc
IEC 60068–2–29
Test Eb
IEC 60068–2–14
Test Na
EN/IEC 60384-14:2005
EN/IEC 60384-14:2005
UL1414
IEC 60068-2-3
Test Ca
Enclosure material of
UL94V–0 flammability class
+40°C and
90 – 95% R.H.
56 days
PhE844
aRtiCLE taBLE
capaci- Box max dimensions
max
tance code in mm
f
o
du/dt article code
µf
B
h
l
mhz v/µs
appRoVaLs
certification Body
ENEC
UL
cUL recognition
specification
EN/IEC 60384-14:2005
lEad sPacinG 22.5 mm
0.10
0.15
0.22
0.33
0.47
D14 8.0 16.0 26.0
D15 9.0 18.5 26.0
D16 11.0 21.5 26.0
D20 13.5 23.0 26.0
D19 15.5 24.5 26.0
3.2
2.6
2.1
1.8
1.5
100
100
100
100
100
PHE844RD6100MR06L2
PHE844RD6150MR06L2
PHE844RD6220MR06L2
PHE844RD6330MR06L2
PHE844RD6470MR06L2
UL 1283
UL 1414
C 22.2 No. 8
C 22.2 No. 1
(U
R
=480 VAC)
(U
R
=250 VAC)
(U
R
=480 VAC)
(U
R
=250 VAC)
lEad sPacinG 27.5 mm
0.22
0.33
0.47
0.68
1.0
F11
F03
F13
F14
F16
10.5
13.5
14.5
17.5
21.0
20.5
23.0
24.5
28.0
30.0
31.5
31.5
31.5
31.5
31.5
2.2
1.7
1.4
1.1
1.0
100
100
100
100
100
PHE844RF6220MR06L2
PHE844RF6330MR06L2
PHE844RF6470MR06L2
PHE844RF6680MR06L2
PHE844RF7100MR06L2
oRdERing inFoRmation
The article code for the standard part is given in the article table.
For other options, see page 11.
maRKing
•
•
•
•
•
•
•
•
•
•
RIFA
RIFA article code
Rated capacitance
Capacitance tolerance code
Rated voltage
X1
Approval marks
Manufacturing date code
IEC climatic category
Passive flammability class
lEad sPacinG 37.5 mm
0.47
0.68
1.0
1.5
2.2
R05
R05
R04
R03
R06
13.0
13.0
15.0
19.0
21.0
24.0
24.0
26.0
36.0
38.0
41.0 1.3 100 PHE844RR6470MR06L2
41.0 1.1 100 PHE844RR6680MR06L2
41.0 0.92 100 PHE844RR7100MR06L2
41.0 0.74 100 PHE844RR7150MR06L2
41.0 0.60 100 PHE844RR7220MR06L2
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.