Tantalum Surface Mount Capacitors – MIL-PRF (CWR Style)
T492 MIL-PRF-55365/8 (CWR11 Style)
Table 1 – Ratings & Part Number Reference
Rated Rated Case Code/
Voltage Cap
Case Size
VDC @ 85°C
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
VDC @ 85°C
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
2.2
3.3
4.7
6.8
10
15
22
47
68
1
1.5
2.2
3.3
4.7
6.8
15
33
47
0.68
1
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
4.7
6.8
µF
KEMET/EIA
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T492A225(1)004(2)(3)(4)
T492A475(1)004(2)(3)(4)
T492B685(1)004(2)(3)(4)
T492B106(1)004(2)(3)(4)
T492B156(1)004(2)(3)(4)
T492C336(1)004(2)(3)(4)
T492D686(1)004(2)(3)(4)
T492D107(1)004(2)(3)(4)
T492A155(1)006(2)(3)(4)
T492A225(1)006(2)(3)(4)
T492A335(1)006(2)(3)(4)
T492B475(1)006(2)(3)(4)
T492B685(1)006(2)(3)(4)
T492B106(1)006(2)(3)(4)
T492C156(1)006(2)(3)(4)
T492C226(1)006(2)(3)(4)
T492D476(1)006(2)(3)(4)
T492D686(1)006(2)(3)(4)
T492A105(1)010(2)(3)(4)
T492A155(1)010(2)(3)(4)
T492A225(1)010(2)(3)(4)
T492B335(1)010(2)(3)(4)
T492B475(1)010(2)(3)(4)
T492B685(1)010(2)(3)(4)
T492C156(1)010(2)(3)(4)
T492D336(1)010(2)(3)(4)
T492D476(1)010(2)(3)(4)
T492A684(1)015(2)(3)(4)
T492A105(1)015(2)(3)(4)
T492A155(1)015(2)(3)(4)
T492B225(1)015(2)(3)(4)
T492B335(1)015(2)(3)(4)
T492B475(1)015(2)(3)(4)
T492C106(1)015(2)(3)(4)
T492D226(1)015(2)(3)(4)
T492D336(1)015(2)(3)(4)
T492A474(1)020(2)(3)(4)
T492A684(1)020(2)(3)(4)
T492A105(1)020(2)(3)(4)
T492B155(1)020(2)(3)(4)
T492B225(1)020(2)(3)(4)
T492B335(1)020(2)(3)(4)
T492C475(1)020(2)(3)(4)
T492C685(1)020(2)(3)(4)
(See below for
part options)
MIL-PRF-55365/8
DC
Part Number
Leakage
(See below for
part options)
CWR11C(6)225(1)(2)(5)
CWR11C(6)475(1)(2)(5)
CWR11C(6)685(1)(2)(5)
CWR11C(6)106(1)(2)(5)
CWR11C(6)156(1)(2)(5)
CWR11C(6)336(1)(2)(5)
CWR11C(6)686(1)(2)(5)
CWR11C(6)107(1)(2)(5)
CWR11D(6)155(1)(2)(5)
CWR11D(6)225(1)(2)(5)
CWR11D(6)335(1)(2)(5)
CWR11D(6)475(1)(2)(5)
CWR11D(6)685(1)(2)(5)
CWR11D(6)106(1)(2)(5)
CWR11D(6)156(1)(2)(5)
CWR11D(6)226(1)(2)(5)
CWR11D(6)476(1)(2)(5)
CWR11D(6)686(1)(2)(5)
CWR11F(6)105(1)(2)(5)
CWR11F(6)155(1)(2)(5)
CWR11F(6)225(1)(2)(5)
CWR11F(6)335(1)(2)(5)
CWR11F(6)475(1)(2)(5)
CWR11F(6)685(1)(2)(5)
CWR11F(6)156(1)(2)(5)
CWR11F(6)336(1)(2)(5)
CWR11F(6)476(1)(2)(5)
CWR11H(6)684(1)(2)(5)
CWR11H(6)105(1)(2)(5)
CWR11H(6)155(1)(2)(5)
CWR11H(6)225(1)(2)(5)
CWR11H(6)335(1)(2)(5)
CWR11H(6)475(1)(2)(5)
CWR11H(6)106(1)(2)(5)
CWR11H(6)226(1)(2)(5)
CWR11H(6)336(1)(2)(5)
CWR11J(6)474(1)(2)(5)
CWR11J(6)684(1)(2)(5)
CWR11J(6)105(1)(2)(5)
CWR11J(6)155(1)(2)(5)
CWR11J(6)225(1)(2)(5)
CWR11J(6)335(1)(2)(5)
CWR11J(6)475(1)(2)(5)
CWR11J(6)685(1)(2)(5)
(See below for
part options)
µA @ +20°C
Max/5 Min
0.5
0.5
0.5
0.5
0.6
1.3
2.7
4.0
0.5
0.5
0.5
0.5
0.5
0.6
0.9
1.3
2.8
4.1
0.5
0.5
0.5
0.5
0.5
0.7
1.5
3.3
4.7
0.5
0.5
0.5
0.5
0.5
0.7
1.5
3.3
5.0
0.5
0.5
0.5
0.5
0.5
0.7
0.9
1.4
µA @ +20°C
Max/5 Min
DF
ESR
Maximum
Operating
Temp
°C
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
°C
MSL
Reflow Temp
≤ 260°C
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temp
≤ 260°C
% @ +20°C
Ω @ +20°C
120 Hz Max 100 kHz Max
6.0
8.0
6.0
8.0
6.0
5.5
6.0
4.0
6.0
3.5
6.0
2.2
6.0
1.1
8.0
0.9
6.0
8.0
6.0
8.0
6.0
8.0
6.0
5.5
6.0
4.5
6.0
3.5
6.0
3.0
6.0
2.2
6.0
1.1
6.0
0.9
4.0
10.0
6.0
8.0
6.0
8.0
6.0
5.5
6.0
4.5
6.0
3.5
6.0
2.5
6.0
1.1
6.0
0.9
4.0
12.0
4.0
10.0
6.0
8.0
6.0
5.5
6.0
5.0
6.0
4.0
6.0
2.5
6.0
1.1
6.0
0.9
4.0
14.0
4.0
12.0
4.0
10.0
6.0
6.0
6.0
5.0
6.0
4.0
6.0
3.0
6.0
2.4
% @ +20°C
Ω @ +20°C
120 Hz Max 100 kHz Max
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
MIL-PRF-55365/8
Part Number
DC
Leakage
DF
ESR
Maximum
Operating
Temp
MSL
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET part number, insert B = Gold-plated, C = Hot solder dipped, H or S = Solder plated or K = Solder fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = −55°C +85°C after Weibull, or 4252 = −55°C +85°C before Weibull.
Designates Surge Current Option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = −55°C +85°C after Weibull, C = −55°C +85°C before Weibull or Z = None. Designates
Surge Current Option.
(6) To complete CWR part number, insert B = Gold-plated, C = Hot solder dipped, H = Solder plated or K = Solder fused. Designates Termination Finish.
Refer to Ordering Information for additional details.
Forum promotion method to easily increase the number of visits to your website and forumHow to increase the number of visits to your website and forum in the fastest time Methods to increase the numbe...
[i=s]This post was last edited by paulhyde on 2014-9-15 03:17[/i]I am working on last year's problem recently. I have been working on it for several days. The constant current source, signal acquisiti...
How to build wince5.0/wince6.0 environment on vs2008? What software do I need to download and install? What is the difference between wince simulator and wince SDK?...
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
According to the Industrial Technology Research Institute of Taiwan, due to factors such as the oil crisis and global warming, the issues of energy conservation and environmental protection have at...[Details]
Traditional
virtual instruments
consist of a data acquisition
board
based on PCI bus and
corresponding software. However, with
the rapid development of
computer
network techno...[Details]
A few days ago, I bought an 8LED flashlight in the market (the flashlight uses No. 5 batteries). Because I had other things to do, I didn't pay attention when purchasing it. When I got home and use...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]
This article introduces a high-reliability, high-power automatic water supply device made with 89C2051 single-chip microcomputer, which has phase loss detection, over-temperature detection, over-cu...[Details]
At present, more than 40 fieldbuses have been developed in the world, among which CAN bus is suitable for application in automobile inspection lines because of its unique features such as strong re...[Details]
A stepper motor is a motor that converts electrical pulse signals into linear or angular displacements. However, the control of stepper motors is usually developed in assembly language or C languag...[Details]
New Automobile
Hydraulic Clutch
The hydraulic control system uses almost 100% advanced engineering plastics, which overcomes the shortcomings of the main and branch cylinders of metal clutc...[Details]