EEWORLDEEWORLDEEWORLD

Part Number

Search

MI-P2TT-IXZ

Description
Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs
File Size129KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

MI-P2TT-IXZ Overview

Military Chassis Mount DC-DC Converters 10 to 300W Single, Dual, Triple Outputs

MI - MegaMod
TM
Family
Military Chassis Mount DC-DC Converters 10 to 300W
Single, Dual, Triple Outputs
Features
Inputs:
28, 155, 165 and 270Vdc
Any output: 2 to 48Vdc
Up to 13.5W/in
3
High efficiency
Size — 1- up half-size: 2.58" x 2.5" x 0.62"
(65,5 x 63,5 x 15,7mm)
Size — 1- up full-size: 4.9" x 2.5" x 0.62"
(124,5 x 63,5 x 15,7mm)
Size — 2- up half-size: 2.58" x 4.9" x 0.62"
(65,5 x 124,5 x 15,7mm)
Size — 2- up full-size: 4.9" x 4.9" x 0.62"
(124,5 x 124,5 x 15,7mm)
Size — 3- up half-size: 2.58" x 7.3" x 0.62"
(65,5 x 185,4 x 15,7mm)
Size — 3- up full-size: 4.9" x 7.3" x 0.62"
(124,5 x 185,4 x 15,7mm)
Product Highlights
Vicor’s MI-MegaMod family
of single, dual, and triple output
DC-DC converters provide power
system designers with cost-
effective, high-performance, off-
the-shelf solutions to applications
that might otherwise require a
custom supply.
Incorporating standard MI-200
or MI-J00 family converters in
rugged, chassis mount packages,
MegaMods can be ordered with
single, dual, or triple outputs,
having a combined output power
of up to 300W. Totally isolated
outputs eliminate efficiency
penalties and output interaction
problems.
Remote sense
ZVS/ZCS power architecture
Low noise FM control
Configuration Chart
Full-Size MegaMods
Single Output
MI-L
MI-M
MI-N
Dual Output
MI-P
MI-Q
Triple Output
MI-R
Number of
Modules
1
2
3
2
3
3
50 – 100W
150 – 200W
300W
100 – 200W
200 – 300W
150 – 300W
4.9" x 2.5" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 4.9" x 0.62"
4.9" x 7.3" x 0.62"
4.9" x 7.3" x 0.62"
Half-Size MegaMods
Single Output
MI-LJ
Dual Output
MI-PJ
Triple Output
MI-RJ
10 – 50W
20 – 100W
30 – 150W
2.58" x 2.5" x 0.62"
2.58" x 4.9" x 0.62"
2.58" x 7.3" x 0.62"
1
2
3
Input Voltage
Nominal Range Transient
2 =28Vdc
5 =155Vdc
6 =270Vdc
7 =165Vdc
18 –
60V
100 – 210V 230V
125 – 400V
(2)
475V
100 – 310V
(3)
50V
(1)
Output Voltage
Z = 2V
Y = 3.3V
0 = 5V
X = 5.2V
W= 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
Product Grade
Full-Size
I = –40°C to +85°C
M = –55°C to +85°C
Half-Size
I = –40°C to +100°C
M = –55°C to +100°C
Output Power/Current
Full-Size
Half-Size
≥5V
<5V
≥5V
<5V
Y
X
W
V
= 50W 10A A = 10W —
= 75W 15A Z = 25W 5A
= 100W 20A Y = 50W 10A
= — 30A
Output Power/Current
≥5V
<5V
V
U
S
=
=
=
150W
200W
30A
60A
Output Power/Current
≥5V
<5V
S
P
=
=
300W
90A
(1)
(2)
(3)
16V operation at 75% load.
These units rated at 75% load from 125 – 150Vin: Full-size – 5Vout @ 100W; 2Vout and 3.3Vout @ 30A
Half-Size – 5Vout @ 50W; 2V and 3.3V @ 10A.
For use with Vicor’s MI-AIM
MI-MegaMod 10/02
1 of 4

Recommended Resources

[Share] Some good technical websites
Find a post and share it with other technology enthusiasts. Electronic Project Expo Network:http://www.51project.com.cn/Microcontroller Kingdom: http://www.21mcu.com/ Practical Electronic Technology N...
fighting Analog electronics
Questions about burst transmission on Avalon bus
I saw a book that said that when the Avalon bus is performing burst transmission, the master port must set all byteenable signal lines valid during the entire burst transmission period. For the slave ...
eeleader-mcu FPGA/CPLD
How to debug WM8960 audio driver with tinymix?
RT, let me share my experience from someone who has used it. I need to learn more....
Wince.Android Embedded System
[Image recognition classification & motion detection & analog signal processing system based on Raspberry Pi 400, Part 4] Try to make an MP3 player...
This player was originally used to analyze the audio spectrum, but I later found that it might not be useful in the project, so I made a small, simple music player, implemented with madplay, as an ent...
donatello1996 DigiKey Technology Zone
Wiring harness insulation resistance test, which method would you choose?
Full-function + batch wiring harness testing, or single-function + time-consuming and labor-intensive wiring harness testing, which one would you choose?...
aigtekatdz Test/Measurement
Post a reply
I found that there are only a few people who post and reply to posts in this forum. Is it just these few people or what?...
斩我明道 Talking

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 227  399  2  1358  263  5  9  1  28  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号