EEWORLDEEWORLDEEWORLD

Part Number

Search

57070103412

Description
AC Power Cords NEMA 5-15P SJT3X18G
CategoryThe connector   
File Size832KB,8 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

57070103412 Online Shopping

Suppliers Part Number Price MOQ In stock  
57070103412 - - View Buy Now

57070103412 Overview

AC Power Cords NEMA 5-15P SJT3X18G

57070103412 Parametric

Parameter NameAttribute value
Product CategoryAC Power Entry Modules
ManufacturerSCHURTER
RoHSDetails
ProductInlets
FilteredFiltered
FusedYes
Switch FunctionNot Switched
Current Rating1 A
Voltage Rating250 V
Mounting StyleScrew
Termination StyleQuick Connect
Connector TypeIEC-950
Flammability RatingUL 94 V-0
Housing MaterialMetallic
Factory Pack Quantity10
Unit Weight3.377835 oz
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
5707
IEC Appliance Inlet C14 or C18 with Filter, Protection Degree IP65 into the Appliance, Fuseholder 1- or
2-pole, Front or Rear Mounting
5707.xxxx.xx2 Mounting from front side
5707.xxxx.xxx.22 with IP 54 V-Lock cord con-
nection
5707 with IP 54 Inlet Gasket
C14
70° C
C18
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on version from front or rear side , Screws with sealing are in-
cluded
- 4 Functions :
Appliance Inlet protection class I or II , Line filter in standard and medi-
cal version , Fuseholder for fuse-links 5 x 20 mm , IP 65 protection into
the appliance
- For front side mounting versions a sealing kit IP 54 for the power sup-
ply connection is available as an accessory: 4700.0021
- Option suffix ".22" offers IP 54 for the power input in combination with
V-Lock cordsets
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
-
-
-
-
-
Extreme robust design
All single elements are already wired
Screw type fuse carrier, slotted
With EMC-shield
Especially for applications in rough environments (see technical data)
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
With solder terminals
Class X1- and Y1-capacitors for enhanced withstand voltage
Medical version M80
Additional factory-mounted sealing (IP54) of power input
Version with current rating 3 A
Other versions on request
-
-
-
-
-
Unique Selling Proposition
-
-
-
-
Sealed power entry module
Strong in Design and Safety
IP 65 protection to the appliance
IP 54 protection to the cord connection
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 8 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 8 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 65 acc. to IEC 60529
from rear-side IP 65 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw, max 3 mm
Mounting screw torque max 0.8 Nm
2 screws M3 with sealing are provided
black / white / metallic, UL 94V-0
appliance inlet/-outlet
C14 / C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 8 A,
Protection Class I or II
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 1.6 W 1-pole/ 1,2 W 2-pole per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'800'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
MTBF
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
EMC Products
1
We need FPGA hardware engineers (familiar with FPGA or ASIC processes)
We are a professional manufacturer of AV system products . As a production-oriented enterprise with independent product design and R&D as the main development direction, we have an excellent R&D team,...
shocking Recruitment
Why did I change the yaffs file system to ext4 file system according to Samsung's official documentation, but the generated file is still yaffs?
[ 3.050782] yaffs: dev is 32505860 name is "mtdblock4" rw [ 3.054725] yaffs: passed flags "" [ 3.072633] yaffs: dev is 32505862 name is "mtdblock6" rw Burn into SD card and inand, always prompt the fo...
Wince.Android Embedded System
Discuss STM32H750——by RCSN
@RCSNDiscuss one of the STM32H750 STM32H750 Part 2 (QSPI Memory Map) Pan it STM32H750 3 (lan8720 Ethernet test --iperf) Discussing STM32H750 Part 4 (Briefly Talking about CANFD Part 1) Panta STM32H750...
okhxyyo stm32/stm8
plc application
Design a ladder diagram to drive the digital tube. Just like how the numbers displayed on the traffic light are driven?...
danglingbo Embedded System
Goodbye 2019, hello 2020+ Busy days never change
[i=s]This post was last edited by led2015 on 2020-1-31 16:04[/i]2019 has passed in the blink of an eye. Sometimes I think that I am another year older. Looking back on my experiences and gains in the ...
led2015 Talking
What are the requirements of pneumatic instruments for compressed air quality?
Pneumatic instruments generally include pneumatic differential pressure transmitters, pneumatic regulators (base regulators, floats are liquid level regulators), electric/pneumatic converters, pneumat...
yunrun Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2460  1350  2252  2777  891  50  28  46  56  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号