FM220A
THRU
FM2100A
SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANG 20 to 100 Volts CURRENT 2.0 Ampere
FEATURES
*
*
*
*
*
*
Low swiching noise
Low forward voltage drop
High current capability
High speed switching
High surge capabitity
High reliability
0.067 (1.70)
0.051 (1.29)
0.180(4.57)
0.160(4.06)
DO-214AC
0.110 (2.79)
0.086 (2.18)
MECHANICAL DATA
* Case: Molded plastic
* Epoxy:Device has UL flammability classification 94V-O
* Lead: MIL-STD-202E method 208C guaranteed
* Mounting position:Any
* Weight: 0.09gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25
o
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
0.091 (2.31)
0.067 (1.70)
0.059 (1.50)
0.035 (0.89)
0.209 (5.31)
0.185 (4.70)
0.012 (0.305)
0.006 (0.152)
0.008 (0.203)
0.004 (0.102)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS
(@ T
A
=25
O
C unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current @ T
T
=120
o
C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Thermal Resistance Junction to Ambient
Total Capacitance
Operating Temperature Range
Storage Temperature Range
SYMBOL
V
RRM
V
RMS
V
DC
I
O
I
FSM
R
θ
JA
C
J
T
J
T
STG
FM220A FM230A FM240A FM250A FM260A FM280A FM290A FM2100A
UNITS
20
14
20
30
21
30
40
28
40
50
35
50
2.0
60
40
60
42
60
80
56
80
90
63
90
100
70
100
Volts
Volts
Volts
Amps
Amps
0
C/W
pF
0
0
130
-55 to + 125
-55 to + 150
C
C
ELECTRICAL CHARACTERISTICS
(@T
A
=25
O
C unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 2.0A DC
Maximum Average Reverse Current
@T
A
= 25
o
C
at Rated DC Blocking Voltage
@T
A
= 100
o
C
NOTES : 1. Measured at 1 MHz and applied reverse voltage of 10 volts.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
V
F
I
R
FM220A FM230A FM240A FM250A FM260A FM280A FM290A FM2100A
UNITS
Volts
mAmps
mAmps
2006-11
0.55
0.70
0.2
2.0
0.85
RATING AND CHARACTERISTICS CURVES ( FM220A THRU FM2100A )
INSTANTANEOUS FORWARD CURRENT, (A)
2.0
AVERAGE FORWARD CURRENT, (A)
20
10
T
A
= 25
O
C
Pulse Width = 300µS
1% Duty Cycle
1.5
2
FM
50A
2
-FM
FM
220
A-F
1.0
1.0
0.5
Single Phase Half Wave 60Hz
Resistive or Inductive Load
0.375" (9.5mm) Lead Length
0
0
25
50
75
100
O
125
150
175
0.1
FM220A
FM230A
FM240A
FM250A
FM260A
FM280A
FM290A
FM2100A
LEAD TEMPERATURE, ( C)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
INSTANTANEOUS REVERSE CURRENT, (mA)
INSTANTANEOUS REVERSE CURRENT, (mA)
100
10
1.0
0.1
0.01
T
J
= 25 C
O
40
M2
A
T
J
= 125
O
C
T
J
= 75
O
C
0.001
FM220A~FM240A
100
A
0.1 0.3
0.5
0.7
0.9
1.1
1.3
1.5
1.7
1.9
2.1
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
100
10
1.0
T
J
= 150
O
C
FM250A~FM260A
FM280A~FM2100A
0.1
T
J
= 125
O
C
0.01
T = 75
O
C
J
0.001
T
J
= 25
O
C
0
20
40
60
80
100
120
140
0
20
40
60
80
100
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
CT, JUNCTION CAPACITANCE, (pF)
T
J
= 25
O
C
FIG.4 TYPICAL REVERSE CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
60
50
40
30
20
10
0
1
8.3mS Single Half Sine-Wave
JEDEC Method
400
200
100
80
60
40
20
10
0.1
0.4
1.0
4
10
40
80
2
4
6 8 10
20
40
80 100
REVERSE VOLTAGE, (V)
NUMBER OF CYCLES AT 60Hz
FIG.5 TYPICAL JUNCTION CAPACITANCE
FIG.6 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.