FRS-R-3

Description
Industrial u0026 Electrical Fuses 600V 3A Dual Elemtent Time Delay
CategoryCircuit protection    Circuit protection   
File Size327KB,3 Pages
ManufacturerEaton
Download Datasheet Parametric Compare View All

FRS-R-3 Online Shopping

Suppliers Part Number Price MOQ In stock  
FRS-R-3 - - View Buy Now

FRS-R-3 Overview

Industrial u0026 Electrical Fuses 600V 3A Dual Elemtent Time Delay

FRS-R-3 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codeunknown
Other featuresRATED BREAKING CAPACITY AT 250 VDC: 20000 A
Fusing characteristicsTIME DELAY
body height127 mm
Body length or diameter20.57 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberFRS-R
Installation featuresINLINE/HOLDER
method of packingBOX
physical size20.57mm x 127mm
Rated breaking capacity200000 A
Rated current3 A
Rated voltage (AC)600 V
Rated voltage (DC)250 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
Technical Data 1017
Effective May 2016
Supersedes August 2013
BUSSMANN
SERIES
Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc,
1/10-60 A, dual element, time-delay fuses
Catalog symbol:
FRS-R-(amp) (non-indicating)
FRS-R-(amp)ID (indicating)
Dual-element fuses can be applied in circuits
subject to temporary motor overloads
and surge currents to provide both high
performance short-circuit and overload
protection
Offers a 10-second time delay at 5 times the
rated current
The time-delay feature makes it possible
to use fuse amp ratings that are much
smaller than those of non-time delay
fuses. Considerable cost savings occur by
permitting the use of smaller size switches,
panels, and fuses themselves.
Provides current limitation to help protect
downstream components from high fault
currents.
Gives motor running back-up protection to
motors without extra costs.
Description:
Advanced protection, energy efficient
Class RK5 dual element, current-limiting,
time-delay fuses with optional open fuse
indication on select ratings
Time-delay – 10 second (minimum) at 500%
of rated current
Specifications:
Ratings
Volts
600 Vac, 300 Vdc (1/10-30 A)
600 Vac, 250 Vdc (35-60 A)
Dimensions - in:
Amps — 1/10-60 A
Interrupting rating
200 kA Vac RMS Sym
20 kA Vdc
Catalog numbers (amps) — Non-indictaing fuses
FRS-R-1/10
FRS-R-1/8
FRS-R-15/100
FRS-R-2/10
FRS-R-1/4
FRS-R-3/10
FRS-R-4/10
FRS-R-1/2
FRS-R-6/10
FRS-R-8/10
FRS-R-1
FRS-R-1 1/8
FRS-R-1 1/4
FRS-R-1 4/10
FRS-R-1 1/2
FRS-R-1 6/10
FRS-R-1 8/10
FRS-R-2
FRS-R-2 1/4
FRS-R-2 1/2
FRS-R-2 8/10
FRS-R-3
FRS-R-3 2/10
FRS-R-3 1/2
FRS-R-4
FRS-R-4 1/2
FRS-R-5
FRS-R-5 6/10
FRS-R-6*
FRS-R-6 1/4*
FRS-R-7*
FRS-R-7 1/2*
FRS-R-8*
FRS-R-9*
FRS-R-10*
FRS-R-12*
FRS-R-15*
FRS-R-17 1/2*
FRS-R-20*
FRS-R-25*
FRS-R-30*
FRS-R-35*
FRS-R-40*
FRS-R-45*
FRS-R-50*
FRS-R-60*
Agency information:
CE, UL Listed, Std. 248-12, Class RK5, Guide
JDDZ, File E4273
®
CSA Certified, C22.2 No. 248.12, Class
1422-02, File 53787
®
CE
Features:
Dual-element feature provides the best
time-delay performance, allowing closer
sizing and superior protection of motors and
transformers
Closer sizing allows for smaller fuses and
less costly switches
Class RK5 fuses with a 200 kA interrupting
rating for use in a broad range of
applications
Provides motor overload, ground fault, and
short-circuit protection
Helps protect motors against burnout from
overloads and single-phasing when sized
properly
* Open fuse indication available by inserting the sufix
“ID. E.g., FRS-R-15ID.

FRS-R-3 Related Products

FRS-R-3 FRS-R-6 FRS-R-1-2 FRS-R-45
Description Industrial u0026 Electrical Fuses 600V 3A Dual Elemtent Time Delay Industrial u0026 Electrical Fuses 600V 6A Dual Elemtent Time Delay Industrial u0026 Electrical Fuses 600V .5A Dual Elemtent Time Delay Industrial u0026 Electrical Fuses 600V 45A Dual Elemtent Time Delay
Maker Eaton Eaton - Eaton
Reach Compliance Code unknown unknown - unknown
Other features RATED BREAKING CAPACITY AT 250 VDC: 20000 A RATED BREAKING CAPACITY AT 250 VDC: 20000 A - RATED BREAKING CAPACITY AT 250 VDC: 20000 A
Fusing characteristics TIME DELAY TIME DELAY - TIME DELAY
body height 127 mm 127 mm - 139.7 mm
Body length or diameter 20.57 mm 20.57 mm - 26.92 mm
Circuit protection type ELECTRIC FUSE ELECTRIC FUSE - ELECTRIC FUSE
Manufacturer's serial number FRS-R FRS-R - FRS-R
Installation features INLINE/HOLDER INLINE/HOLDER - INLINE/HOLDER
method of packing BOX BOX - BOX
physical size 20.57mm x 127mm 20.57mm x 127mm - 26.92mm x 139.7mm
Rated breaking capacity 200000 A 200000 A - 200000 A
Rated current 3 A 6 A - 45 A
Rated voltage (AC) 600 V 600 V - 600 V
Rated voltage (DC) 250 V 250 V - 250 V
Guideline CSA; UL CSA; UL - CSA; UL
surface mount NO NO - NO
Terminal shape END CAP END CAP - END CAP

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2084  1168  1130  512  923  42  24  23  11  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号