Specialty Fuses Fuse, NH0, gL [3] 35A, 500V
CategoryCircuit protection    Circuit protection   
File Size130KB,6 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet Parametric View All

35NH0GL Online Shopping

Suppliers Part Number Price MOQ In stock  
35NH0GL - - View Buy Now

35NH0GL Overview

Specialty Fuses Fuse, NH0, gL [3] 35A, 500V

35NH0GL Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberNH0
Base Number Matches1
NH KNIFE BLADE
NH fuses are typically used for power
distribution applications and to protect
large electrical devices such as motors,
drives, etc. They are available in seven
sizes with a current range of 2 to 1600
Amps.
NH fuses have knife blades at both ends,
which mount into Fuse Bases. Fuse
Bases are available in one or three pole
designs and can be panel or DIN rail
mounted.
Please refer to pg 19 for NH Fuse
Accessories.
Operating Classes
gL/gG - Line Protection
Slow, typically used for distribution
circuits or resistive loads.
NH00 (NHC00)
3
Ordering Information
Operating Class gL / gG
(VDE 0636 / IEC 269)
Line Protection up to 500V AC
(660V available)
Current/
Voltage
2/500V AC
4/500V AC
6/500V AC
10/500V AC
16/500V AC
20/500V AC
25/500V AC
32/500V AC
35/500V AC
40/500V AC
50/500V AC
63/500V AC
80/500V AC
100/500V AC
125/500V AC
160/500V AC
2/660V AC
4/660V AC
6/660V AC
10/660V AC
16/660V AC
20/660V AC
25/660V AC
32/660V AC
35/660V AC
40/660V AC
50/660V AC
63/660V AC
80/660V AC
100/660V AC
125/500V AC
160/500V AC
16/660V AC
20/660V AC
25/660V AC
32/660V AC
35/660V AC
40/660V AC
50/660V AC
63/660V AC
80/660V AC
100/660V AC
125/660V AC
160/660V AC
Cat. No.
2NH00GL
4NH00GL
6NH00GL
10NH00GL
16NH00GL
20NH00GL
25NH00GL
32NH00GL
35NH00GL
40NH00GL
50NH00GL
63NH00GL
80NH00GL
100NH00GL
125NH00GL
160NH00GL
2NH00AM-6
4NH00AM-6
6NH00AM-6
10NH00AM-6
16NH00AM-6
20NH00AM-6
25NH00AM-6
32NH00AM-6
35NH00AM-6
40NH00AM-6
50NH00AM-6
63NH00AM-6
80NH00AM-6
100NH00AM-6
125NH00AM
160NH00AM
16NH00GR-6
20NH00GR-6
25NH00GR-6
32NH00GR-6
35NH00GR-6
40NH00GR-6
50NH00GR-6
63NH00GR-6
80NH00GR-6
100NH00GR-6
125NH00GR-6
160NH00AR-6
1
1
1
1
1
1
1
1
1
1
1
Dim.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Std. Pk.
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Typical Marking: gL/gG
aM - Motor Protection
Fast acting short circuit protection, but
slow acting overload protection.
NH00 Fuses Operating Class gL / gG are
available in 660V, and with insulated tags.
Typical Marking: aM
Green imprint.
aR - Semiconductor Protection
Partial range, short circuit protection for
devices such as diodes, SCRs, etc.
Operating Class aM
(VDE 0636 / IEC 269)
Motor Protection up to 660V AC
Typical Markings: Ultra Rapid™,
Sitor™, Silcu™, Protistor™,
Recticur™, Ultra Quick
TM
, aR,
gR - Semiconductor Protection
Full range overload and short circuit
protection for devices such as diodes,
SCRs, etc.
Typical Markings: Ultra Rapid™,
Sitor™, Silcu™, Protistor™,
Recticur™, Ultra Quick
TM
,
gR,
Mostly red, orange or blue imprint.
Super Fast Blow Operating Class aR / gR
(VDE 0636 / IEC 269)
Semiconductor Protection up to 660V AC
(1000V available)
F
L
2
1
Also available in Operating Class aR.
Also available in 1000V. Designate suffix “-1”
(ex. 32NH0GR-1).
Size NHC00 will be supplied in place of
NH00 at manufacturer discretion.
Knife blade is available with screw holes, please
designate a “B” after the size, (ex. 250NH3BAR-6).
L
1
W
11.5
C
D
2
3
4
T
16
Altech Corp.
®
q
35 Royal Road Flemington NJ 08822-6000
q
Phone (908) 806-9400
q
Fax (908) 806-9490
q
www.altechcorp.com
Comparison between TI and Freescale's Zigbee?
Comparison between TI and Freescale's Zigbee? Can anyone compare the pros and cons of the two solutions?...
ljt8015 RF/Wirelessly
GPS navigation, CMMB mobile TV, MP3, MP4, MP5 functions 4.3" screen
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:59[/i] [size=10.5pt]Function Introduction[/size][size=10.5pt][/size] [size=10.5pt]Adopts advanced ARM+DSP dual-core architecture, 240MH...
zhskn Mobile and portable
I am not talented, please help me again~~~ About the line sequence of stepper motor
The sequence given on the datasheet is: input signal output signal PA PB | B /BA /A ----------- |--------------- LH | LHLH .....The following is the sequence, etc... Due to design reasons, I can only ...
skyairllly Embedded System
Transfer: Theoretical analysis and practical application of TPS5430 positive and negative voltage and high current output
1. Overview Usually we use TPS5430 to generate positive voltage. Its high current capability of 3A is very powerful. However, you may not know that it can also be used to generate negative voltage. Th...
qwqwqw2088 Analogue and Mixed Signal
Based on ST FOC5.3 self-made IHM08 V3 board: non-sensing/sensing Hall/sensing encoder/torque mode and other reference programs/circuits...
[align=center] [b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]music_586[/size]. If you need to reprint or use it for commercial purposes, you must obtain the author...
music_586 Motor Drive Control(Motor Control)
Newbie high score ask: WDM program structure problem
WDM driver is layered, with a stack structure, including bus driver, function driver, filter driver, etc. 1. So which layer does the driver we wrote (including driver entry, IPR processing, etc.) belo...
atommann Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 630  2779  2072  1811  1183  13  56  42  37  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号