ACK-400

Description
Specialty Fuses 48VDC 400A Fuse
CategoryCircuit protection    Circuit protection   
File Size1MB,3 Pages
ManufacturerEaton
Download Datasheet Parametric Compare View All

ACK-400 Online Shopping

Suppliers Part Number Price MOQ In stock  
ACK-400 - - View Buy Now

ACK-400 Overview

Specialty Fuses 48VDC 400A Fuse

ACK-400 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time9 weeks 6 days
Is SamacsysN
body height95.25 mm
Body length or diameter1.06 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size1.06mm x 95.25mm
Rated current400 A
Rated voltage (DC)80 V
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
Technical Data 1040
Effective June 2017
Supersedes
June 2016
BUSSMANN
SERIES
Stud-mounted fuses
Catalog symbol:
ACK-_
Description:
Bussmann series stud-mounted fuse.
®
Catalog numbers (amps)
ACK-10
ACK-15
ACK-20
ACK-25
ACK-30
ACK-35
ACK-40
ACK-50
ACK-60
ACK-70
ACK-75
ACK-80
ACK-100
ACK-120
ACK-140
ACK-150
ACK-160
ACK-175
ACK-200
ACK-225
ACK-250
ACK-300
ACK-400
Specifications:
Ratings
•   
Volts - 130 Vdc (or less)
• 
130 Vdc - (10-100 A)
• 
72 Vdc - (120-200 A)
• 
48 Vdc - (225-300 A)
• 
Test specifications
Fuse
ACK
*Approximately.
Load
200%
300%
500%
Opening time
100 Seconds*
35 Seconds*
13 Seconds*
80 Vdc - (400 A)
Amps - 10-400 A
Interrupting rating - 10 kA
•   
•   
Agency information
• 
Recommended fuse blocks:
Catalog
number
ACK 10-30
ACK 35-60
ACK 70-100
Block
number
4228
3411
2322
Catalog
number
ACK 120-200
ACK 225-400
Block
number
3569
3578
UL
®
Recognized 15-300A, Guide JFHR2, File
E56412
Features:
• 
These fuses avoid needless openings from
starting currents or surges
A fuse link which operates only on very high
overloads or short-circuits
Thermal cutout functions on low overloads –
the thermal cutout cannot operate quickly at
any load, hence long timelag is obtained on
high overloads of short duration
This long time-lag also makes it unnecessary
to use extra large size or over-size fuses
Dimensions in inches and (mm)
A
B
C
2.5”
(63.5)
3.0”
(76.20)
3.5”
(88.90)
3.750”
(95.25)
3.750”
(95.25)
0.375”
(9.53)
0.470”
(11.94)
0.547”
(13.89)
0.750”
(19.05)
0.610”
(15.49)
0.500”
(12.70)
0.685”
(17.40)
0.750”
(19.05)
0.750”
(19.05)
0.750”
(19.05)
• 
• 
Dimensions - in (mm):
A
D
C
B
E
G
F
• 
Catalog
number
ACK 10-30
ACK 35-60
ACK 70-100
ACK 120-200
ACK 225-400
D
0.250”
(6.35)
0.344”
(8.74)
0.312”
(7.92)
0.375”
(9.52)
0.312”
(7.92)
E
0.557”
(14.15)
0.812”
(20.63)
1.062”
(26.98)
1.062”
(26.98)
1.062”
(1.062)
F
0.588”
(14.94)
0.860”
(21.84)
1.15”
(29.21)
1.15”
(29.21)
1.125”
(28.58)
G
0.031”
(0.79)
0.051”
(1.30)
0.050”
(1.27)
0.050”
(1.27)
0.050”
(1.27)
Note: 10-60 amp fuses use brass terminals and ferrules.
70-400 amp fuses use copper terminals and ferrules.

ACK-400 Related Products

ACK-400 BK-ACK-30 GP70ER-4223-DB50 ACK-10 3569 3411 ACK-80
Description Specialty Fuses 48VDC 400A Fuse Automotive Fuses FUSETRON DUAL ELE Fixed Resistor, Metal Film, 2W, 422000ohm, 500V, 0.5% +/-Tol, 50ppm/Cel, Specialty Fuses 130VDC 10A Fuse Fuse Holder Fuse Block Screw Mount Fuse Holder BUSS FUSEBLOCK Specialty Fuses 130VDC 80A Fuse
Reach Compliance Code compliant - compliant compliant - - compliant
ECCN code EAR99 - EAR99 EAR99 - - EAR99

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1389  1995  129  1679  2557  28  41  3  34  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号