Part Number

Search

3120-F521-P7T1-W01D-10A

Description
Circuit Breakers An extremely versatile range of rocker switch/thermal circuit breakers
CategoryCircuit protection   
File Size2MB,16 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3120-F521-P7T1-W01D-10A Online Shopping

Suppliers Part Number Price MOQ In stock  
3120-F521-P7T1-W01D-10A - - View Buy Now

3120-F521-P7T1-W01D-10A Overview

Circuit Breakers An extremely versatile range of rocker switch/thermal circuit breakers

3120-F521-P7T1-W01D-10A Parametric

Parameter NameAttribute value
Product CategoryCircuit Breakers
ManufacturerE-T-A [E-T-A Circuit Breakers]
RoHSDetails
ProductThermal Circuit Breakers
TypeThermal Overcurrent
Current Rating10 A
Voltage Rating AC240 VAC
Voltage Rating DC50 VDC
Number of Poles2 Pole
Actuator TypeRocker
Operating Temperature Range- 30 C to + 60 C
IlluminatedNot Illuminated
Height25 mm
Length48 mm
Mounting StyleSnap In
Factory Pack Quantity1
Termination StyleBlade
Voltage Rating50 VDC, 240 VAC
Width35 mm
Thermal Circuit Breaker 3120-F...
Description
The 3120 circuit breaker/switch combination is an ON/OFF switch
with integral overcurrent protection (S-type TO CBE to EN/IEC
60934). The trip element is a bimetal. Type 3120 is ideally suited for
overload protection of motors, pumps, transformers and cables.
The 3120 circuit breaker is also available as a switch-only version in
accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1).
Product characteristics:
l
rocker or push button actuation
l
single pole and double pole versions
l
reliable switching behaviour (positively trip-free)
l
convenient snap-in mounting
l
international approvals
Options and add-on modules:
illumination
l
water splash protection
l
auxiliary contacts
l
under voltage trip
l
remote trip
l
magnetic trip
l
push-in terminals
l
appliance inlet module
l
1
Technical data
For details please see Technical information
Rated voltage
Current rating range
AC 240 V, DC 50 V
0.1...20 A
(up to 30A upon request for single pole
units)
30,000
30,000
30,000
30,000
operations
operations
operations
operations
at
at
at
at
at
at
at
at
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
inductive
inductive
resistive
inductive
inductive
inductive
inductive
inductive
Typical applications
Medical and laboratory equipment, apparatus and machine
construction, professional tools, household and garden appliances,
offices machines, audio equipment, machine tools
Typical life 1-pole
0.1...20 A
0.1...4 A
4.5...16 A
DC 28 V:
0.1...20 A
Typical life 2-pole
AC 240 V:
AC 240 V:
DC 50 V:
Current ratings and internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
0.1...16 A 50,000 operations
17...20 A 30,000 operations
DC 50 V:
0.1...16 A 50,000 operations
17...20 A 50,000 operations
Ambient temperature
-30 … 60 °C
Insulation coordination
(IEC 60664)
Dielectric strength
Operating area
pole to pole (2-pole)
Insulation resistance
Interrupting capacity I
cn
2.5 kV /2 reinforced insulation at
operating area
test voltage AC 3,000 V
test voltage AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A
10 x I
N
2.5...20 A
1-pole 150 A
2-pole 250 A
Interrupting capacity (UL 1077)
I
N
1-pole, 2- pole
1-pole, 2- pole
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A, C, 1
1000 A, C, 1
Degree of protection
(IEC 60529)
Vibration
Current consumption of illumination
Operating voltage
DC 12 V
DC 24 V
DC 48 V
AC 115 V
AC 230 V
Current consumption
Y
5.2 mA
4.5 mA
4.5 mA
2.8 mA
2.2 mA
R
2 mA
2.2 mA
2 mA
1.1 mA
0.9 mA
G
1.4 mA
1.6 mA
1.6 mA
1 mA
0.9 mA
Shock
Corrosion
Humidity
Mass
operating area IP40
terminal area IP00
with water splash cover IP54 or IP66
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
test to IEC 60068-2-11, test Ka
240 hrs in 95 % RH
test to IEC 60068-2-78,
test Cab
approx. 33 g (2-pole)
approx. 27 g (1-pole)
approx. 42 g (2-pole with PT terminals)
1746
www.e-t-a.de
1
Can evc read and write excel?
My development platform is an ARM (2440) development board, and the wince5.0 operating system comes with an EXCEL VIEWER. Therefore, I want to use Automation in evc to operate Excel. However, there is...
forzhanghua Embedded System
CC2640R2F ADC
Now I provide an ADC subroutine that I wrote myself, which has been verified by many people and can be used.The subroutine is as follows: #include "AppAdc.h" #include inc/hw_types.h #include ti/sysbio...
Jacktang Wireless Connectivity
Chapter 1 Transmission Line Theory
[table=98%][tr][td=1,1,100][align=center][font=宋体]§[/font]1.1 Introduction[/align][/td][td=1,1,250][/td][/tr][/table][table=98%][tr][td=1,1,470][/td][td=1,1,128][url=http://www.hdmicrowave.com/htdocs/...
赵高 RF/Wirelessly
Read and write a file in the SD card
I created a dialog box with two edit boxes, one for editing the contents of the written file and the other for displaying the contents of the read file. There are also two buttons, one for writing and...
wangjian801213 Embedded System
How to manage the key files in CPU card
For a CPU card with ISO7816 protocol, I first write two key files: one in MF\EF1 with 3 keys; the other in MF\DF\EF2. Why when I read the card, I use 3DES encryption and external authentication to rea...
qqyd Embedded System
Looking for hardware developers for project outsourcing
Since there is a project involving hardware development, we are now looking for people with rich hardware development experience in Wuhan (preferably in Wuchang) to cooperate on the project. The speci...
yuhaishan Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 791  860  1601  2504  141  16  18  33  51  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号