Part Number

Search

2036-20-SM-RPLF

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE MINI 3POLE 200VOLT
CategoryWireless rf/communication    Telecom circuit   
File Size219KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2036-20-SM-RPLF Online Shopping

Suppliers Part Number Price MOQ In stock  
2036-20-SM-RPLF - - View Buy Now

2036-20-SM-RPLF Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE MINI 3POLE 200VOLT

2036-20-SM-RPLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT PACKAGE
Reach Compliance Codecompliant
Factory Lead Time6 weeks
JESD-30 codeX-XXSS-X
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTin (Sn)
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
n
Balanced Mini-TRIGARD™ Series
(5 mm diameter, 7.3 mm length)
n
Ideal for board level protection of
broadband circuits
n
Leadless, surface mount for economical
assembly
n
Stable breakdown throughout life
M
PL
IA
NT
n
High surge current rating, low insertion loss
n
UL Recognized
n
RoHS compliant* version available
Bourns now offers a surface mount (SM) 3-electrode Gas Discharge Tube (GDT) surge protection device. The industry-leading quality
and features of the Bourns
®
miniature 2036 TRIGARD™ series GDT continues in this new SM version for “pick and place”
manufacturing techniques. The 2036 SM device is ideal for board level protection of high bandwidth applications such as xDSL,
cable broadband and high speed Ethernet, due to its high energy handling capability, long and stable life performance and low
capacitance of less than 2 pF. Bourns subminiature family of GDTs measure only 5 mm in diameter and are the smallest high
performance GDTs in the telecom industry. Bourns
®
GDTs are designed to prevent damage from transient disturbances by acting as
a “crowbar” in creating a short-to-ground circuit during conduction. When a voltage transient surge exceeds the defined breakdown
voltage level of the GDT, the device becomes ionized and conduction takes place within a fraction of a microsecond. When the surge
passes and system voltage returns to normal levels, the GDT returns to its high-impedance (off) state.
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
(1)
*R
oH
S
2036-xx-SM Precision Gas Discharge Tube Surge Protector
CO
2036-07
75 V
250 V
525 V
2036-30
300 V
500 V
650 V
2036-09
90 V
250 V
550 V
2036-35
350 V
600 V
750 V
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR
IA E
NT
*
Characteristics
LE
AD
F
RE
E
Model No.
2036-15
2036-20
150 V
200 V
350 V
500 V
425 V
575 V
2036-23
230 V
450 V
600 V
2036-47
470 V
750 V
950 V
2036-25
250 V
475 V
625 V
2036-60
600 V
850 V
1100 V
Model No.
2036-40
2036-42
400 V
420 V
650 V
825 V
675 V
850 V
75 ns
10
10
Ω
70 V
10 V
0.5 A
2 pF
150 ms
Impulse Sparkover voltage is defined as typical values of distribution.
Impulse Transverse Delay ............................... 1000 V/μs..........................................................<
Insulation Resistance (IR) ............................... 100 V (50 V for Model 2036-07 & 2036-09) ......>
Glow Voltage ................................................... 10 mA................................................................~
Arc Voltage ...................................................... 1 A .....................................................................~
Glow-Arc Transition Current .......................................................................................................<
Capacitance..................................................... 1 MHz ...............................................................<
DC Holdover Voltage
(2)
................................... >135 V, (52 V for Model 2036-07, & -09, ..........<
80 V for Model 2036-15)
Impulse Discharge Current .............................. 20000 A, 8/20 µs
(3)
...........................................
10000 A, 8/20 µs ...............................................>
200 A, 10/1000 µs ............................................>
2000 A, 10/350 µs .............................................
200 A, 10/700 µs ..............................................>
Alternating Discharge Current ......................... 20 Arms, 1 s
2
....................................................
10 Arms, 1 s ......................................................>
Storage Temperature ..................................................................................................................
Operating Temperature...............................................................................................................
Climatic Category (IEC 60068-1)................................................................................................
1 operation minimum
10 operations
300 operations
1 operation
500 operations
1 operation minimum
10 operations
-55 to +105 °C
-55 to +105 °C
55/105/21
Notes:
• UL Recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ GDTs is the total current equally divided between each line to ground.
• Surface Mount (SM) parts may show a temporary increase in DCBD after the solder reflow process. Most devices will recover within 24
hours time. It should be noted that there is no quality defect nor change in protection levels during the temporary change in DCBD.
• Sparkover limits after life ±25 % (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60), IR >10
8
Ω.
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available on request.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
• Bourns recommends reflowing surface mount devices per IPC/JEDEC J-STD-020 rev D.
(2)
Network applied.
(3)
DC Sparkover may exceed ±25 % but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
【Show off the prizes】Wireless mouse
Participated in forum activities. Won a prize. A package arrived this morning from the post office. I opened it and saw that it was a wireless mouse. I was so proud of it....
youluo Talking
BlueNRG video tutorial: BlueNRG-1 ProjectCode
...
littleshrimp ST - Low Power RF
MSP430--Low Power Mode
[p=26, null, left][color=#333333][font=Arial]1.CPU structure: 16 registers R0-R15, 16-bit arithmetic logic unit ALU and an instruction control unit. [/font][/color][/p][p=26, null, left][color=#333333...
nino Microcontroller MCU
How to isolate VCC and VDD in 6N137
Could any expert tell me how to isolate VCC and VDD in 6N137 high-speed optoelectronic isolation chip in the same PCB? Is there any simple method? Or a special chip? Thank you!...
ben007sky2003 Power technology
Touch screens are growing rapidly and their appeal is irresistible
The rapid growth of touch screens is spurring fierce competition, driving technology development, and sparking interest from OEMs. iSuppli has predicted that global shipments of major touch screen tec...
songrisi MCU
Hello, Xiangban
I see that STM32 has VFQFPN36 package, but I have never seen what VFQFPN36 package looks like. Can you give me a protel99 pcb package diagram? ? ? Thank you...
victor9911 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 179  675  2351  2273  1728  4  14  48  46  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号