Environmental Test Equipment TEMP/HUMIDITY METER W/CAL AND DATA
CategoryTopical application    Test and measurement   
File Size198KB,2 Pages
ManufacturerFluke
Websitehttps://www.fluke.com
Download Datasheet Parametric Compare View All

FLUKE-971-NIST-Z540-W-DATA-CERT Online Shopping

Suppliers Part Number Price MOQ In stock  
FLUKE-971-NIST-Z540-W-DATA-CERT - - View Buy Now

FLUKE-971-NIST-Z540-W-DATA-CERT Overview

Environmental Test Equipment TEMP/HUMIDITY METER W/CAL AND DATA

FLUKE-971-NIST-Z540-W-DATA-CERT Parametric

Parameter NameAttribute value
Product CategoryEnvironmental Test Equipment
ManufacturerFluke
RoHSDetails
Factory Pack Quantity1
Unit Weight6.699999 oz
Fluke 971
Temperature Humidity Meter
Technical Data
Quickly take accurate humidity
and temperature readings in
the air. Temperature and
humidity are two important fac-
tors in maintaining optimal
comfort levels and good indoor
air quality. The Fluke 971 is
invaluable for facility mainte-
nance and utility technicians,
HVAC-service contractors, and
specialists who assess indoor
air quality (IAQ). Lightweight,
rugged, and easy to hold, the
Fluke 971 is the perfect tool for
monitoring problem areas.
The Fluke 971 has:
Backlit dual display of humidity and temperature
99 record storage capacity
Ergonomic design with belt clip and protective holster
Quick-response capacitance sensor with twist-open protective cover
General Features
Compact and lightweight (190 g/6.7 oz)
Temperature range from -20 °C to 60 °C (-4 °F to 140 °F)
Measures dew point and wet bulb
Relative humidity from 5 % to 95 %
Min/Max/Avg data hold
Low battery indicator
Specifications
Temperature range
Temperature accuracy
0 °C to 45 °C
-20 °C to 0 °C and 45 °C to 60 °C
32 °F to 113 °F
-4 °F to 32 °F and 113 °F to 140 °F
Resolution
Temperature update rate
Temperature sensor type
Relative humidity range
Relative humidity accuracy
10 % to 90 % R.H. @ 23 °C (73.4 °F)
<10 %, > 90 % R.H. @ 23 °C (73.4 °F)
Resolution
Response time (humidity)
Humidity sensor
Data storage
-20 °C to 60 °C (-4 °F to 140 °F)
± 0.5 °C
± 1.0 °C
± 1.0 °F
± 2.0 °F
0.1 °C / 0.1 °F
500 ms
NTC
5 % to 95 % R.H.
± 2.5 % R.H.
± 5.0 % R.H.
0.1 % R.H.
For 90 % of total range - 60 sec. with
1 m/s air movement
Electronic capacitance polymer film sensor
99 points

FLUKE-971-NIST-Z540-W-DATA-CERT Related Products

FLUKE-971-NIST-Z540-W-DATA-CERT FLUKE-CO-220 FLUKE-CO-205 FLUKE-971
Description Environmental Test Equipment TEMP/HUMIDITY METER W/CAL AND DATA Environmental Test Equipment CARBON MONOXIDE ME Environmental Test Equipment CARBON MONOXIDE AS Power Transformers PC Class2/3, 20VA/8P 24VDC CT@0.8A Series
Product Category Environmental Test Equipment Environmental Test Equipment Environmental Test Equipment Environmental Test Equipment
Manufacturer Fluke Fluke Fluke Fluke
RoHS Details Details Details Details
Factory Pack Quantity 1 1 1 1
Unit Weight 6.699999 oz 6.702053 oz - 6.702053 oz
Measured Components or Conditions - Flue Gas Flue Gas Temperature, Humidity
Measures - Flue Gas Flue Gas Temperature and Humidity
About HOHO's experience in applying for a development board
HOHO applied for the following development board There are pictures to share with you: (taken by mobile phone, may not be clear)Email address to which the application form should be sent market@prochi...
daicheng Embedded System
Beginners ask questions about arm linux kernel driver development
I would like to ask you, if I want to learn arm linux kernel driver development, do I need to have a good understanding of the chip structure, such as registers and so on....
三一 Linux and Android
Want to build a smart home, how to start? Receive this collection of information
Smart home is a field that has been attracting much attention in recent years. With the continuous development of technologies such as 5G industry, cloud computing, AIoT, and big data, the market dema...
arui1999 Download Centre
Audio amplifier circuit noise problem???
The audio amplifier circuit I made has a lot of noise, a rustling sound, and it burned two transistors, so I connected a larger resistor in series to reduce the voltage division, but the noise is supe...
fredli Analog electronics
Nonlinear Electronic Circuits Test Paper
Nonlinear Electronic Circuits Test Paper 2003-2006...
feifei Industrial Control Electronics
Problems with the 5V3-pin DCDC voltage reference chip
I used a 3.3V 3-pin DCDC reference source chip REF2933 before. Now I find that it is not suitable and I need a 5V one. Has anyone used a 5V 3-pin DCDC voltage reference chip? Can you recommend one? Th...
chenbingjy Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1875  892  2282  1646  17  38  18  46  34  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号