EEWORLDEEWORLDEEWORLD

Part Number

Search

2DR30

Description
Circuit Breakers 30A MCB RITON DCHAR 277VAC UL508
CategoryCircuit protection    Circuit protection   
File Size129KB,2 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet Parametric View All

2DR30 Online Shopping

Suppliers Part Number Price MOQ In stock  
2DR30 - - View Buy Now

2DR30 Overview

Circuit Breakers 30A MCB RITON DCHAR 277VAC UL508

2DR30 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Circuit protection typeTHERMAL CIRCUIT BREAKER
Base Number Matches1
D-TRIP
CHARACTERISTICS
Application Examples:
ONE POLE
ONE POLE PLUS NEUTRAL
High inrush motors, transformers,
power supplies, heaters and reactive
loads. Relatively long thermal trip
delay and very high magnetic trip
point.
Prototype testing is recommended in
motor applications where the relatively
long thermal trip delay may not
provide adequate motor overload
protection. Motor-integral overload
protectors are recommended, with the
V-EA-D providing disconnect, backup
thermal protection and additional short
circuit and energy let-through
protection.
1D
Rated
Current
0.3A
0.5A
0.75A
0.8A
1.0A
1.6A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
6.0A
8.0A
10A
12A
12.5A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
10/0.3A - 32A = 1.4kg (3.1 lb.)
40A - 63A = 1.6kg (3.5 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Type/
Cat. No.
1DU03
1DU05
1DU075
NA
1DU1
1DU1.6
1DU2
1DU2.5
1DU3
1DU3.5
1DU4
1DU5
1DU6
1DU8
1DU10
NA
NA
1DU13
1DU15
1DU16
1DU20
1DU25
1DU30
1DU32
1DU40
1DU50
1DU60
1DU63
Approvals
UL
UL
UL
2DN
Type/
Cat. No.
2DNU03
2DNU05
2DNU075
NA
2DNU1
2DNU1.6
2DNU2
2DNU2.5
2DNU3
2DNU3.5
2DNU4
2DNU5
2DNU6
2DNU8
2DNU10
NA
NA
2DNU13
2DNU15
2DNU16
2DNU20
2DNU25
2DNU30
2DNU32
2DNU40
2DNU50
2DNU60
2DNU63
277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
5/0.3A - 32A = 1.3kg (2.9 lb.)
40A - 63A = 1.45kg (3.2 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Approvals
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Type Designation
2
D
N
U
(a) (b) (c) (d)
60
(e)
(a)
= Number of Poles
(b)
= Trip Characteristic
(c)
= Blank: without neutral pole
= N:
with neutral pole
(d)
= U:
UL/CSA version
= R:
ring tongue terminals,
UL/CSA version
= Blank: European version
(e)
= Rated Current
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Approvals:
*
*
*
*
*
*
*
*
UL508 Listed
Voltage Rating
Interrupting Capacity
(UL/CSA - Ratings)
Group Short Circuit
(UL/CSA - Ratings)
Interrupting Capacity (VDE - Ratings)
Mechanical Endurance
Calibration Temperature
Standard Pack and Weight
Terminal Size Acceptability
Terminal Torque
Basic Dimensions (Elevation View)
Not European standard rating.
Please refer to page 21 for specific
applications.
DC rating (Manufacturer’s self certification):
91.5 mm
(3.60 in.)
91.5 mm
(3.60 in.)
One pole 48VDC, two pole series 125VDC
* VDE pending
17.5 mm (0.69 in.)
35 mm (1.38 in.)
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
12
China's first-class mobile development forum
www.devdiv.net The product developed by the moderator has won the second place in the Nokia Technology Award. Nokia has embedded it in a large number of its mobile phones and invited two experts from ...
tiandi8734 Embedded System
I was fired for refusing to bring my computer home during the holidays, but the result was comfortable!
[Source: Programmer’s Life WeChat Official Account] A programmer named Zhang in Shanghai was fired for refusing to take his computer home to work during the Spring Festival holiday. Subsequently, Zhan...
eric_wang Talking
I have two questions, I don't know how to answer them
I just learned C6000 and now I have two problems. Please give me some advice, thank you!1. Why is the interrupt flag IFR = 0x00000400 when I enter the program, which means there is an INT10 request. I...
swaty Analogue and Mixed Signal
DIY crystal radio that does not require power
A crystal radio is a passive radio without an amplification circuit, which is composed of an antenna, a ground wire , a basic tuning circuit and a crystal as a detector . It is the simplest radio rece...
bqgup Creative Market
Is there a start signal when FSMC writes data?
After looking at the timing diagram, I still don't quite understand how FSMC determines the data to be sent, that is, what the start signal is. My understanding is that the address is reloaded, but I ...
zmsxhy stm32/stm8
What kind of resistor is this? How many watts? What is it usually used for?
[img]D:\dianz.bmp[/img]...
kiahe Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 147  4  26  2900  1409  3  1  59  29  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号