EEWORLDEEWORLDEEWORLD

Part Number

Search

2036-15-SMLF

Description
LDO Voltage Regulators
CategoryWireless rf/communication    Telecom circuit   
File Size219KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2036-15-SMLF Online Shopping

Suppliers Part Number Price MOQ In stock  
2036-15-SMLF - - View Buy Now

2036-15-SMLF Overview

LDO Voltage Regulators

2036-15-SMLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Parts packaging codeMODULE
package instructionROHS COMPLIANT PACKAGE
Contacts3
Reach Compliance Codecompliant
Factory Lead Time6 weeks
JESD-30 codeX-XXSS-X
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTin (Sn)
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
n
Balanced Mini-TRIGARD™ Series
(5 mm diameter, 7.3 mm length)
n
Ideal for board level protection of
broadband circuits
n
Leadless, surface mount for economical
assembly
n
Stable breakdown throughout life
M
PL
IA
NT
n
High surge current rating, low insertion loss
n
UL Recognized
n
RoHS compliant* version available
Bourns now offers a surface mount (SM) 3-electrode Gas Discharge Tube (GDT) surge protection device. The industry-leading quality
and features of the Bourns
®
miniature 2036 TRIGARD™ series GDT continues in this new SM version for “pick and place”
manufacturing techniques. The 2036 SM device is ideal for board level protection of high bandwidth applications such as xDSL,
cable broadband and high speed Ethernet, due to its high energy handling capability, long and stable life performance and low
capacitance of less than 2 pF. Bourns subminiature family of GDTs measure only 5 mm in diameter and are the smallest high
performance GDTs in the telecom industry. Bourns
®
GDTs are designed to prevent damage from transient disturbances by acting as
a “crowbar” in creating a short-to-ground circuit during conduction. When a voltage transient surge exceeds the defined breakdown
voltage level of the GDT, the device becomes ionized and conduction takes place within a fraction of a microsecond. When the surge
passes and system voltage returns to normal levels, the GDT returns to its high-impedance (off) state.
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
(1)
*R
oH
S
2036-xx-SM Precision Gas Discharge Tube Surge Protector
CO
2036-07
75 V
250 V
525 V
2036-30
300 V
500 V
650 V
2036-09
90 V
250 V
550 V
2036-35
350 V
600 V
750 V
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR
IA E
NT
*
Characteristics
LE
AD
F
RE
E
Model No.
2036-15
2036-20
150 V
200 V
350 V
500 V
425 V
575 V
2036-23
230 V
450 V
600 V
2036-47
470 V
750 V
950 V
2036-25
250 V
475 V
625 V
2036-60
600 V
850 V
1100 V
Model No.
2036-40
2036-42
400 V
420 V
650 V
825 V
675 V
850 V
75 ns
10
10
Ω
70 V
10 V
0.5 A
2 pF
150 ms
Impulse Sparkover voltage is defined as typical values of distribution.
Impulse Transverse Delay ............................... 1000 V/μs..........................................................<
Insulation Resistance (IR) ............................... 100 V (50 V for Model 2036-07 & 2036-09) ......>
Glow Voltage ................................................... 10 mA................................................................~
Arc Voltage ...................................................... 1 A .....................................................................~
Glow-Arc Transition Current .......................................................................................................<
Capacitance..................................................... 1 MHz ...............................................................<
DC Holdover Voltage
(2)
................................... >135 V, (52 V for Model 2036-07, & -09, ..........<
80 V for Model 2036-15)
Impulse Discharge Current .............................. 20000 A, 8/20 µs
(3)
...........................................
10000 A, 8/20 µs ...............................................>
200 A, 10/1000 µs ............................................>
2000 A, 10/350 µs .............................................
200 A, 10/700 µs ..............................................>
Alternating Discharge Current ......................... 20 Arms, 1 s
2
....................................................
10 Arms, 1 s ......................................................>
Storage Temperature ..................................................................................................................
Operating Temperature...............................................................................................................
Climatic Category (IEC 60068-1)................................................................................................
1 operation minimum
10 operations
300 operations
1 operation
500 operations
1 operation minimum
10 operations
-55 to +105 °C
-55 to +105 °C
55/105/21
Notes:
• UL Recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ GDTs is the total current equally divided between each line to ground.
• Surface Mount (SM) parts may show a temporary increase in DCBD after the solder reflow process. Most devices will recover within 24
hours time. It should be noted that there is no quality defect nor change in protection levels during the temporary change in DCBD.
• Sparkover limits after life ±25 % (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60), IR >10
8
Ω.
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available on request.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
• Bourns recommends reflowing surface mount devices per IPC/JEDEC J-STD-020 rev D.
(2)
Network applied.
(3)
DC Sparkover may exceed ±25 % but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Launchpad programming problem
After each program is burned on launchpad, I have to plug and unplug the USB to see the program results. Is there any other way? :titter:...
水木未名 Microcontroller MCU
If both SPI1 and SPI2 of STM32f103RBT6 are used in one design, will there be a conflict? Thank you
[table=98%] [tr][td][font=宋体][size=4]The SPI1 and SPI2 of STM32f103RBT6 are both used in a design. SPI1 and SPI2 are connected to different peripheral modules to realize different functions. Will ther...
心的方向001 MCU
Homemade 51+DSP development board
This development board adopts DSP + 51 solution. The written program can be directly downloaded to DSP through 51 serial port for running. It can learn both single chip microcomputer and DSP. For begi...
weizhiwei 51mcu
Anti-interference measures for single chip microcomputer
In the application of embedded systems, the anti-interference performance of single-chip microcomputers is an important indicator of system reliability, and anti-interference design is an important co...
rwogn MCU
I would like to ask you a question about IAR for MSP430 simulation!!
1. I used the file fet140_ta01.c in the FET140 folder in the FET_examples directory to build a project.2. In the iar for msp430 environment, why can't I enter the timer interrupt using software simula...
z4126 Microcontroller MCU
STM32 hot restart crash problem?
The program needs to runthe NVIC_SystemReset() function, but once it runs, the system will freeze. There is no way to debug in a single step, so I would like to ask where the problem may be.There is n...
guangxv stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2377  2069  1536  2385  2772  48  42  31  49  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号