EEWORLDEEWORLDEEWORLD

Part Number

Search

PA4000-3CH-GPIB

Description
Power Analyzers Multi-phase Power Analyzer 3 CH W/GPIB
CategoryTopical application    Test and measurement   
File Size2MB,9 Pages
ManufacturerTektronix
Websitehttps://www.tek.com/
Download Datasheet Parametric Compare View All

PA4000-3CH-GPIB Online Shopping

Suppliers Part Number Price MOQ In stock  
PA4000-3CH-GPIB - - View Buy Now

PA4000-3CH-GPIB Overview

Power Analyzers Multi-phase Power Analyzer 3 CH W/GPIB

PA4000-3CH-GPIB Parametric

Parameter NameAttribute value
Product CategoryPower Analyzers
ManufacturerTektronix
RoHSDetails
Number of Channels3 Channel
Factory Pack Quantity1
Power Analyzer
PA4000 Datasheet
Applications
Power Conversion
Power Generation
Inverters
Motor Drives
Electrical Propulsion
UPS
Frequency Converters
Tektronix PA4000 Power Analyzers deliver highly accurate, multi-channel
power, energy, and efficiency measurements. Precisely-matched inputs,
unique Spiral Shunt
technology, and advanced signal processing deliver
high accuracy even with highly modulated waveforms and crest factors as
high as 10. The versatile PA4000 offers comprehensive power
measurements. Dual current shunts provide optimal resolution from
microwatts to kilowatts. Harmonics analysis up to the 100
th
harmonic, and
motor analysis with torque and speed inputs are included in the standard
instrument. Every PA4000 comes with multiple PC interfaces, PC software,
and USB flash drive support to help you collect and analyze data.
Electric and Hybrid Vehicle
High-Efficiency Lighting
Consumer Electronics
Standby Power
Flexible voltage and current input choices to
fit your application
The PA4000 is the only instrument of its kind to feature both high- and low-
range internal current shunts in each input module. The 30-Amp shunt is
perfect for many applications and can accept up to 200 A peak; but for
measuring low-current devices the 1 A shunt provides increased resolution
and accuracy for measurements down into the microamp range. For
measuring currents over 30 Amps, a selection of matching external current
transducers are available in several styles, including high-accuracy
transducers up to 1000 A.
The PA4000's voltage inputs can accept up to 1000 V
rms
, 2000 V
peak
,
continuous.
Key features
1 to 4 Input Modules allows several configurations to match your
application
High measurement accuracy of 0.04% (basic voltage & current
accuracy) for demanding test requirements
Dual internal current shunts for each module maximize accuracy for
high- and low-current measurements
Unique Spiral Shunt
TM
design maintains stability over variations in
current, temperature, etc. (patent applied for)
Proprietary frequency detection algorithms ensure rock-solid frequency
tracking even on noisy waveforms
Application-specific test modes simplify instrument setup and reduce
the likelihood of user error
Easy data export to USB flash drive or remote PC software, for
reporting and/or remote control
Many standard features such as comm ports and harmonic analysis
eliminate costly upgrade options
PA4000 Rear Panel - Input Modules

PA4000-3CH-GPIB Related Products

PA4000-3CH-GPIB PA4000-2CH-GPIB PA4000-2CH-15V PA4000-3CH-15V PA4000-4CH-GPIB PA4000-4CH-15V
Description Power Analyzers Multi-phase Power Analyzer 3 CH W/GPIB Power Analyzers Multi-phase Power Analyzer 2 CH W/GPIB Power Analyzers Multi-phase Power Analyzer 2 CH W/15V Power Analyzers Multi-phase Power Analyzer 3 CH W/15V Power Analyzers Multi-phase Power Analyzer 4 CH W/GPIB Power Analyzers Multi-phase Power Analyzer 4 CH W/15V
Product Category Power Analyzers Power Analyzers Power Analyzers Power Analyzers Power Analyzers Power Analyzers
Manufacturer Tektronix Tektronix Tektronix Tektronix Tektronix Tektronix
RoHS Details Details Details Details Details Details
Number of Channels 3 Channel 2 Channel 2 Channel 3 Channel 4 Channel 4 Channel
Factory Pack Quantity 1 1 1 1 1 1
stk600 - atmega2560 issue
I just bought a stk600-atmega2560 development board and was going to download the program to atmega2560 via ISP. The computer connected to STK600 successfully, but the following error message kept app...
vippon Microchip MCU
MTK7688 Modify WIFI SSID and password
MTK7688 Modify WIFI SSID and password We first enter the console and modify etc/config/wireless. You can also modify it through the WEB. Change the WIFI hotspot and password to the following command: ...
wateras1 RF/Wirelessly
TCP VS UDP(2)
Differences between TCP and UDP TCP---Transmission Control Protocol, provides a connection-oriented, reliable byte stream service. Before the client and server exchange data with each other, a TCP con...
小龙王2010 Linux and Android
The problem of capacitor placement in the filter circuit behind the rectifier bridge
For the filter circuit behind the rectifier bridge, we usually choose different capacitor values C, one large and one small, for better filtering.But there is a question: if the two capacitors are pla...
Aguilera Power technology
Let's guess the topic of the 2010 Fujian University Student Electronic Competition
Let's guess the topic of the 2010 Fujian University Student Electronic Competition...
h429860511 Talking
Why is the main torch subjected to wind tunnel testing?
The main torch of the Beijing Olympics is elegant and light, like a beautiful musical note. It is this shape that makes the seemingly simple project extremely difficult. Even aerospace technology had ...
songbo Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 70  230  1741  357  2897  2  5  36  8  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号