EEWORLDEEWORLDEEWORLD

Part Number

Search

DMS-20LCD-1-9

Description
Digital Panel Meters 9V LED +/- 2V
CategoryTopical application    Test and measurement   
File Size206KB,6 Pages
ManufacturerMurata
Websitehttps://www.murata.com
Download Datasheet Parametric View All

DMS-20LCD-1-9 Online Shopping

Suppliers Part Number Price MOQ In stock  
DMS-20LCD-1-9 - - View Buy Now

DMS-20LCD-1-9 Overview

Digital Panel Meters 9V LED +/- 2V

DMS-20LCD-1-9 Parametric

Parameter NameAttribute value
Product CategoryDigital Panel Meters
ManufacturerMurata
RoHSNo RoHS Version Available
Equipment TypeVoltmeters
Display TypeLCD, 3.5 Digit
Operating Supply Voltage7.5 V to 14 V
Operating Supply Current230 uA
Input Voltage+/- 2 V
Description/FunctionLow power
Dimensions11 mm L x 35 mm W x 22 mm H
Height22 mm
Length11 mm
Mounting StylePanel, Board
Factory Pack Quantity5
Width35 mm
Unit Weight0.388014 oz
www.murata-ps.com
DMS-20LCD Series
3½ Digit, LCD Display Digital Panel Voltmeters
FEATURES

Lowest cost

Lowest power, 2mW

Subminiature size:
1.38" x 0.88" x 0.43"
35mm x 22mm x 11mm

Large (0.37"/9.4mm), enhanced-contrast LCD display

Epoxy-encapsulated, 12-pin DIP

or pc-board mountable
Panel

differential input voltage ranges
4

accuracy, ±1 count (±0.05%)
High

Single +5V supply or 9V battery

Low-battery annunciator

User-selectable decimal point placement

to +60°C temperature range
0
DMS-20LCD Series, 3½ Digit, LCD Display, Digital Voltmeters represent the ultimate
combination of low price, low power, small size and high performance in digital meters.
Epoxy encapsulated in a subminiature (1.38” x 0.88” x 0.43”), 12-pin DIP package, these
completely self-contained, fully operational meters offer a combination of ruggedness,
long-term reliability and component-like ease-of-use simply not available in any other
meters.
Incorporating a precision reference and a factory-calibrated, autozeroing A/D converter,
DMS-20LCD meters are extremely accurate (±1 count) and are only slightly larger than
their 0.37"/9.4mm, enhanced-contrast, LCD displays. All models incorporate a built-in
bezel and are easily mounted in either panels or pc boards. Both backlit and non-backlit
versions are available.
DMS-20LCD meters have 4 differential input voltage ranges (±200mV, ±2V, ±20V and
±200V) and a user-friendly input structure. Input impedance is a minimum 800k. CMRR
is typically 86dB with a CMV of ±2V. Non-inverting inputs are overvoltage protected to
±100V (±250V for the ±200V input model).
All DMS-20LCD meters operate from a single +5V supply (drawing 400µA) or a single
+9V supply/battery (drawing 230µA). All models have a low-battery ("B") annunciator and
feature autopolarity changeover and overrange indication.
Also available is an application/evaluation board (DMS-EB2) that plugs directly onto the
back of any DMS-20LCD allowing direct inputs for common applications such as 4-20mA
inputs, zero/gain adjust, decimal point location, and input voltage dividing.
SIMPLIFIED SCHEMATIC DIAGRAM
+5V
+5V SUPPLY/ 1
+BATTERY
–5V
N.C.
2
DC/DC
CONVERTER
3
V+
2
12
(–) INPUT LO
0.01μF
R2
1
R1
V–
≈+2.0V
909k
11
(+) INPUT HI
5V RETURN/ 3
–BATTERY
J1
0 Vdc
A/D
CONVERTER
10 ANALOG
COMMON
DATA
DP 3
4
9
N.C./BACKLIGHT
4
5
DP 2
+5V
8
REFERENCE OUT
6
DP 1
7
REFERENCE IN
1
R2 is not used on ±200mV (-0) models or ±2V (-1) models.
R2 = 100k on ±20V (-2) models and 9.1k on ±200V (-3) models.
Only used on ±200mV (-0) and ±2V (-1) models.
3
DC/DC converter is not used on 9V-powered models,
J1 is connected.
Used on backlit models only.
N.C. for non-backlit models.
 
2
4
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MPM_DMS20LCD.C01
Page 1 of 6
High sensitivity wireless microphone
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:00[/i]...
lorant Mobile and portable
Application of Digital Signal Processor (DSP) in Series Active Power Filter
Active Power Filter, a new technology that uses power electronics technology to suppress harmonics and improve power quality, has become a new hot spot in the field of power system research in recent ...
zbz0529 DSP and ARM Processors
LM3S series solidified Bootloader problem~~urgent~~
I am using DK-LM3S9B96... It has a solidified Bootloader. I have studied how to start the Bootloader and want to force it to start from the solidified Bootloader when powered on, without checking whet...
MrStone123 Microcontroller MCU
Is it necessary to connect a data acquisition card when using Matlab serial port data acquisition?
I want to use MATLAB serial port to collect data, why do people say online that I need a data acquisition card or something? . . ....
大家都是好朋友 Analogue and Mixed Signal
Usage of OpenStore
hFlash = OpenStore(L"MSFlash"); hFlash = OpenStore(L"DSK0:"); What is the difference between these two sentences? Why can I only use the first sentence in the case of multi-bin, but only the second se...
frank_wt Embedded System
It’s Mid-Autumn Festival…
Happy Mid-Autumn Festival! It feels a bit cold......
冬立自动化技术 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 563  1945  1191  2109  2829  12  40  24  43  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号