MB203A20V-01

Description
Digital Multimeters +/-20VDC Input Range
CategoryTopical application    Test and measurement   
File Size63KB,3 Pages
ManufacturerLinear ( ADI )
Websitehttp://www.analog.com/cn/index.html
Download Datasheet Parametric Compare View All

MB203A20V-01 Online Shopping

Suppliers Part Number Price MOQ In stock  
MB203A20V-01 - - View Buy Now

MB203A20V-01 Overview

Digital Multimeters +/-20VDC Input Range

MB203A20V-01 Parametric

Parameter NameAttribute value
Product CategoryDigital Multimeters
ManufacturerLinear ( ADI )
RoHSNo
ProductVolt Meters
Factory Pack Quantity1
MB203A2V/MB203A20V
Single Board Precision DVM with direct Character Display Module Driver
The
ALD MB203 is a precision +/-5½-digit Digital Voltmeter (DVM) printed circuit board that contains the
ALD500R/ALD523D A/D Converter – Display Module Controller chipset. It features direct 2 x 16 Character
Display Module interface, calibrated analog input (w/scalable input ranges), and digital circuitry to communicate
with PC or other microprocessors. It is designed to be used as a stand-alone, embedded system component in a
variety of applications including digital panel meters, customized instrumentation displays, temperature monitoring,
high resolution DVM’s, weigh scales and others. Direct Full-scale analog input range is +/-2.00000V DC with a
linearity of 0.005%. ALD's 18-bit plus sign integrating dual-slope analog processor (ALD500) functions as the
input device and the ALD523D microprocessor IC implements the digital conversion, control mode and I/O
functions for interfacing with a variety of LCD/VFD multi-line Character Display Modules. In addition, the MB203
also drives and manages a 2x16 LCD or VFD Character Display Module.
The MB203 supports three optional Mode versions, each populated with different components and configurations:
Mode A – calibrated reference mode, used primarily for measurements against a calibrated reference
voltage, typically required in precision voltmeter applications. Mode A is the default version of MB203A.
Mode B – ratio-metric mode, intended for measurements against a ratio-metric reference voltage, such as
those required in weigh scale applications. Mode B is a simple application specific adaptation of the
standard MB203A.
Mode C – Display only mode, used for display applications and can be programmed to be compatible with
most industry standard serial binary input data formats – up to 31 serial bits plus sign bit. Mode C is a
simple application specific adaptation of the standard MB203A.
The MB203 board has a provision for PC interface (DB25), BASIC interface modules, and input resistor divider
network for input scaling. Optional MS-DOS Software (P/N - MBCDROM) is also available for user setup and
calibration. Only one copy of the software is necessary, regardless of the number of boards in use. Inputs are single
ended or optionally fully differential, and features automatic zero and automatic input polarity detection. There are
also optional socket/footprints for input pre-amplifier and 2-input differential input analog switch. A DB25
connector is provided on-board, to conveniently interconnect the MB203 to a personal computer (PC) via the
parallel printer port for initial setup and calibration. Standard PC software is included to configure the ALD523D
digital controller chip and establish input scaling and user-defined alphanumeric "Title and Unit fields" for the
display module, which are then uploaded and stored in the EEPROM on the MB203. Once initial set up and
calibration is completed, the MB203 board only requires a single +5V DC power supply to operate.
Hardware and Software Features
User switch-selectable Display Ranges with pre-programmed Unit fields.
Measurement Range: +/-2.00000V DC direct input.
(Other ranges are user configurable and scalable, using both hardware and software scaling)
All solid-state construction.
User selectable +/-3½ to +/-6½ digits.
Differential analog inputs with auto-polarity and auto-zero.
User configurable software and hardware parameters.
Calibration for positive and/or negative inputs.
Smart Input Filtering (Sample Averaging) selection for noise reduction and accurate displays.
Optional MS-DOS software for user operation, setup, and calibration is sold separately.
Rev 2.0 © 2012 Advanced Linear Devices, Inc. 415 Tasman Drive, Sunnyvale, CA 94089-1706 Tel: (408) 747-1155 Fax: (408) 747-1286
MB203
www.aldinc.com
1 of 3

MB203A20V-01 Related Products

MB203A20V-01 MB203A-Txxxx MB203A2V MB203A20V MB203A2V-01 MB203CHIPSET
Description Digital Multimeters +/-20VDC Input Range Digital Multimeters DVM Bd, Mode A +/- 5 1/2 Digit Digital Multimeters +/-2VDC Input Range Digital Multimeters +/-20VDC Input Range Digital Multimeters +/-2VDC Input Range Digital Multimeters MB203A Chipset
Product Category Digital Multimeters Digital Multimeters Digital Multimeters Digital Multimeters Digital Multimeters Digital Multimeters
Manufacturer Linear ( ADI ) Linear ( ADI ) Linear ( ADI ) Linear ( ADI ) Linear ( ADI ) Linear ( ADI )
RoHS No Details No No No No
Factory Pack Quantity 1 1 1 1 1 1
Product Volt Meters Volt Meters - Volt Meters Volt Meters -

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 845  1258  2641  1165  1295  18  26  54  24  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号