EEWORLDEEWORLDEEWORLD

Part Number

Search

84871120

Description
Controllers HIL CURRENT CONTROL UN-OVER 24-240VAC
CategoryMechanical and electronic products    relay   
File Size476KB,3 Pages
ManufacturerCrouzet
Environmental Compliance
Download Datasheet Parametric Compare View All

84871120 Online Shopping

Suppliers Part Number Price MOQ In stock  
84871120 - - View Buy Now

84871120 Overview

Controllers HIL CURRENT CONTROL UN-OVER 24-240VAC

84871120 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCrouzet
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Is SamacsysN
Other featuresCOIL POWER AC: 2975 MW
body width35 mm
body height65.5 mm
Body length or diameter90 mm
Coil current (AC) maximum value0.012 A
Maximum coil current (DC)0.003 A
Coil power600 mW
Coil resistance80000 Ω
Maximum coil voltage (AC)240 V
Maximum coil voltage (DC)240 V
Coil/Input Power TypeAC/DC
Contact (AC) maximum rated R load5A@250VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@250VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)250 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Installation featuresDIN-RAIL MOUNT
operating hours300 ms
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
physical size90mm x 35mm x 65.5mm
GuidelineCE; CEI; CSA; IEC; UL
Relay actionLATCHED
Relay functionSPDT
Relay typeMONITORING RELAY
release time1500 ms
sealIP20; IP30; MOISTURE PROOF
surface mountNO
Termination typeSNAP-ON
Base Number Matches1
HIL
Monitoring Relays
Current Monitoring Relays
Modular Carril DIN 35 mm
Control of AC and DC currents
Automatic recognition of AC/DC
Measurement ranges from 2 mA to 10 A
Choice between over and undercurrent
True RMS measurement
Selectable latching (memory) function
Specifications
Functions
Over or undercurrent
Power supply
Supply voltage Un
Voltage supply tolerance
Operating range
Polarity with DC voltage
AC supply voltage frequency
Galvanic isolation of power supply/measurement
Power consumption at Un
Immunity from micro power cuts
Inputs and measuring circuit
Frequency of measured signal
Max. measuring cycle time
Threshold adjustment
Maximum 3-phase voltage
Adjustable hysteresis
Display precision
Repetition accuracy with constant parameters
Measuring error with voltage drift
Measuring error with temperature drift
Time delays
Delays on power up (Ti)
Delay on thresold crossing Tt
Repetition accuracy with constant parameters
Reset time
Delay on pick-up
1 →20 s (0, +10 %)
0,1 →3 s (0, +10 %)
± 2 %
1500 ms
< 300 ms
0 Hz, 40 →70 Hz
30 ms/True RMS measurement
10 →100 % of the range
277 / 480 V (3-phase mains with earth)
5 →50 % of displayed threshold
±10 % of full scale
± 0,5 %
± 1 % across the whole range
± 0,05 % / °C
24 V →240 V AC/DC
-15 % / +10 %
20,4 V →264 V AC/DC
No
50 / 60 Hz ± 10 %
No
3.5 VA in AC/0.6 W in DC
50 ms
Measurement range
2 mA →500 mA
Nominal voltage (V)
24 →240 V AC/DC
Code
84871120

84871120 Related Products

84871120 84873023 84873221
Description Controllers HIL CURRENT CONTROL UN-OVER 24-240VAC Controllers MWU 208-480V 3PHASE SEQ-LOS-UVOLT Controllers H3USN 220 480VAC UN OVER VOLT u0026 NEUTRL
Is it Rohs certified? conform to conform to -
package instruction ROHS COMPLIANT ROHS COMPLIANT -
Reach Compliance Code unknown unknown -
ECCN code EAR99 EAR99 -
body width 35 mm 17.5 mm -
body height 65.5 mm 65.5 mm -
Body length or diameter 90 mm 90 mm -
Contact (AC) maximum rated R load 5A@250VAC 5A@250VAC -
Maximum contact current (AC) 5 A 5 A -
Maximum contact current (DC) 5 A 5 A -
Contact (DC) maximum rated R load 5A@250VDC 5A@250VDC -
Maximum contact voltage (AC) 250 V 250 V -
Maximum contact voltage (DC) 250 V 250 V -
Contact/Output Power Type AC/DC AC/DC -
Electrical life 100000 Cycle(s) 100000 Cycle(s) -
Installation features DIN-RAIL MOUNT DIN-RAIL MOUNT -
operating hours 300 ms 650 ms -
Maximum operating temperature 50 °C 50 °C -
Minimum operating temperature -20 °C -20 °C -
physical size 90mm x 35mm x 65.5mm 90mm x 17.5mm x 65.5mm -
Guideline CE; CEI; CSA; IEC; UL CE; CSA; GL; IEC; UL -
Relay action LATCHED MOMENTARY -
Relay function SPDT SPDT -
Relay type MONITORING RELAY MONITORING RELAY -
release time 1500 ms 1500 ms -
seal IP20; IP30; MOISTURE PROOF IP20; IP30; MOISTURE PROOF -
surface mount NO NO -
Termination type SNAP-ON SNAP-ON -
Base Number Matches 1 1 -

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2425  2442  2646  1638  1902  49  50  54  33  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号