Strain Guage Sensor, Gage, -15Psi Min, 185Psi Max, 0.15%, 1-5V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200HG2G0IPB3MB Overview

Strain Guage Sensor, Gage, -15Psi Min, 185Psi Max, 0.15%, 1-5V, Cylindrical

2200HG2G0IPB3MB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknown
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset1V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range1-5V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type9/16 MALE
Maximum pressure range185 Psi
Minimum pressure range-15 Psi
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/O MATE
Base Number Matches1
【Download】TI Power Management Guide 2012
[i=s]This post was last edited by dontium on 2015-1-23 13:00[/i]This guide includes a variety of solutions, such as: portable and line-powered solutions, digital power solutions, point-of-load solutio...
德州仪器 Analogue and Mixed Signal
Switching configuration scheme for battery testing
The use of batteries is rapidly expanding in consumer and industrial applications. Their testing requirements generally depend on their chemistry, specifications, application, and whether they are pri...
程序天使 Test/Measurement
What are the reasons for unsuccessful FPGA configuration?
I am using a microcontroller to configure an FPGA (EPF10K10), but during configuration, the CONF_DONE pin is always low and there is no response. Why? Also, how does the FPGA determine when the config...
eeleader FPGA/CPLD
Request TW2866 datasheet!!!
I sent an email to the official website, but no reply! I can't find it by searching anywhere, please help me!Thank you!...
wolf25 Industrial Control Electronics
What are the steps to create an MFC smart application in VS2005
What are the steps to create an MFC smart application in VS2005? How to create it so that it can run on the development board of WINCE5.0 system?...
dongdongbo119 Embedded System
Instantiation of failed. The design unit was not found. How to solve this problem?
Instantiation of failed. The design unit was not found, how to solve this situation eeworldpostqq...
不是归人是过客 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 168  2520  913  2169  2161  4  51  19  44  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号