Description
Mains Power Connector, 1A, 250VAC, Male, Solder Terminal
CategoryThe connector    The connector   
File Size696KB,2 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F.MM.01A.20.25 Overview

Mains Power Connector, 1A, 250VAC, Male, Solder Terminal

F.MM.01A.20.25 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320, CSA, UL, VDE
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings1A, 250VAC
Manufacturer's serial numberF.MM
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
IEC Inlet Filters
F.MH-F.MK-F.ML-F.MM-F.MP-F.MQ-F.MR-F.MS
series
With fuse holder, bipolar switch and voltage selector
This series gives a high level of suppression within a compact
enclosure. The IEC 60320 inlet power entry module combines 1 or 2
fuse holders for US and IEC fuses, with a bipolar rocker switch, earth
choke and input voltage selector.
Designed for use in business, consumer, test and medical equipment
for international markets.
Current ratings from 1A to 6A
Comprehensive range of filter performance options
Integral single or twin fuse holder
Optional voltage selector
Optional earth line choke
Horizontal or vertical mounting
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
fuse holder for 1 fuse (F.MH. - F.ML. - F.MP. - F.MR)
or 2 fuses (F.MK. - F.MM. - F.MQ. - F.MS)
5 x 20mm (IEC) or 6.3 x 32mm (US),
bipolar rocker switch,
voltage selector 110/220Vac (F.MH - F.MK - F.ML
- F.MM only); internal components sealed with
self-extinguishing resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.MH, F.MK, FML, FMM versions now available in
vertical mounting version - (F.**.***.**.**.010) with
no approvals.
Filter Range
(example pt no. - F.MH.01A.20.25)
Code
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
I
R
L
1
(A) (mH)
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
L
2
Cx
1
(mH) (µF)
0.22
Cx
2
(µF)
0.1
Cy
(pF)
2 x 4700
2 x 4700
2 x 4700
F.MH.
F.MK.
F.MQ.
F.MS.
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Bipolar rocker
Switches:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
10(4)A / 250Vac (Rated current),
50000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Voltage selector:
110-220Vac (F.MH - F.MK - F.ML - F.MM only).
Leakage current (I
L
):
at 220V, 50Hz, max value
F.ML.
F.MM.
F.MP.
F.MR.
0.65 0.22
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
2 x 0.003
0.65 0.22
l
L
(mA)
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
R
(M
Ω
)
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
No approvals, Circuit Diagram D
No approvals, Circuit Diagram C
Not applicable to FMP,FMR
Approvals
32
.010 = Vertical mounting option (addition to standard pt no.)
25 = Rocker switch
26 = Illuminated rocker switch
Circuit Diagram:
H = 1 fuse
A
K = 2 fuses
L = 1 fuse + earth choke
B
M = 2 fuses + earth choke
P = 1 fuse, single pole switch (no voltage selector)
D
Q = 2 fuses, single pole switch (no voltage selector)
R = 1 fuse, double pole switch (no voltage selector)
C
S = 2 fuses, double pole switch (no voltage selector)
ARM Getting Started Tutorial
If you need it, download it...
zhengyingwei ARM Technology
launchpad, animation
I saw a video online that used a Nokia 5110 LCD to make a black and white animation of a bad apple. I suddenly wanted to make one myself. Has anyone done this before? Could you please give me some adv...
智波景严 Microcontroller MCU
A Day in the Life of an Analog Design Engineer at Texas Instruments
[i=s]This post was last edited by dontium on 2015-1-23 12:46[/i] TI design engineer Vicki is currently working on designing the next generation of low-power data converters. He will take you into his ...
德州仪器_视频 Analogue and Mixed Signal
WINCE about register value printing
I've been testing SDHC under WINCE recently, and added some RETAILMSG/DEBUGMSG print information. It turns out that the return value from the oscilloscope is different from the value in the register S...
bobo_cuckoo Embedded System
16 Ways of Flowing Lights Using C Language Basics for Single Chip Microcomputers (V)
[b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]tiankai001[/size]. If you need to reprint or use it for commercial purposes, you must obtain the author's consent and...
tiankai001 51mcu
National Standards for Power Quality
...
okhxyyo Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1229  1583  2352  1314  247  25  32  48  27  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号