Part Number

Search

F37D18Y14S21102

Description
MIL Series Connector, 14 Contact(s), Stainless Steel, Male, Solder Terminal, Receptacle
CategoryThe connector    The connector   
File Size35KB,1 Pages
ManufacturerAPI Technologies
Websitehttp://www.apitech.com/about-api
Download Datasheet Parametric View All

F37D18Y14S21102 Overview

MIL Series Connector, 14 Contact(s), Stainless Steel, Male, Solder Terminal, Receptacle

F37D18Y14S21102 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerAPI Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: MIL-C-83723
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationGOLD
Contact completed and terminatedGold (Au)
Contact point genderMALE
Contact materialCOPPER ALLOY
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionYES
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsYES
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size18
Termination typeSOLDER
Total number of contacts14
Base Number Matches1
MIL-C-83723, Extended Shell
Series III
M83723/73/74 Bayonet Coupling Jam Nut Receptacle
Shell
Size
8
10
12
14
16
18
20
22
24
A
.979
(24.87)
1.104
(28.04)
1.291
(32.79)
1.391
(35.33)
1.516
(38.51)
1.641
(41.68)
1.766
(44.86)
1.954
(49.63)
2.079
(52.81)
B
1.068
(27.13)
1.192
(30.28)
1.380
(35.05)
1.505
(38.23)
1.630
(41.40)
1.756
(44.60)
1.860
(47.24)
2.068
(52.53)
2.160
(54.86)
C
.575
(14.61)
.700
(17.78)
.825
(20.96)
.950
(24.13)
1.075
(27.31)
1.140
(28.96)
1.265
(32.13)
1.340
(34.04)
1.515
(38.48)
L
1.830
(46.48)
1.830
(46.48)
1.830
(46.48)
1.830
(46.48)
1.830
(46.48)
1.830
(46.48)
1.830
(46.48)
1.860
(47.24)
1.860
(47.24)
M83723/81 Bayonet Coupling Hermetic Jam Nut Receptacle
Shell
Size
8
10
12
14
16
18
20
22
24
A
.979
(24.87)
1.104
(28.04)
1.291
(32.79)
1.391
(35.33)
1.516
(38.51)
1.641
(41.68)
1.766
(44.86)
1.954
(49.63)
2.079
(52.81)
B
1.068
(27.13)
1.192
(30.28)
1.380
(35.05)
1.505
(38.23)
1.630
(41.40)
1.756
(47.24)
1.860
(47.24)
2.068
(52.53)
2.160
(54.86)
C
.490
(12.45)
.550
(13.97)
.740
(18.80)
.800
(20.32)
.925
(23.50)
1.050
(26.67)
1.240
(31.50)
1.300
(33.02)
1.490
(37.85)
L
1.670
(42.42)
1.670
(42.42)
1.670
(42.42)
1.670
(42.42)
1.670
(42.42)
1.670
(42.42)
1.670
(42.42)
1.670
(42.42)
M83723/77/78 Bayonet Coupling Straight Plug
Shell
Size
8
10
12
14
16
18
20
22
24
A
.766
(19.46)
.906
(23.01)
1.078
(27.38)
1.141
(28.98)
1.266
(32.16)
1.375
(34.93)
1.510
(38.35)
1.625
(41.28)
1.760
(44.70)
B
.590
(14.99)
.720
(18.29)
.840
(21.34)
.965
(24.51)
1.090
(27.69)
1.14
(29.08)
1.270
(32.26)
1.395
(35.43)
1.520
(38.61)
V
1/2-20 UNEF-2A
5/8-24 UNEF-2A
3/4-20 UNEF-2A
7/8-20 UNEF-2A
1-20 UNEF-2A
1 1/16-18 UNEF-2A
1 3/16-18 UNEF-2A
1 5/16-18 UNEF-2A
1 7/16-18 UNEF-2A
Dimensions in inches
(mm)
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
219
Filtered Connectors
1.670
(42.42)
How to use the osal_set_event(task_id,event_flag) function?
[color=#666666][font=arial, 宋体]Is the osal_set_event(task_id,event_flag) function only used in task polling? For example, if I define a new event EVT, do I need to use this function to add the event t...
mr_j RF/Wirelessly
PPP protocol! Cannot get IP address during link establishment!
During the PPP protocol link establishment process! Both LCP and PAP passed! At the NCP stage! As soon as I sent a message to the ISP requesting an IP, I received a link termination message! I was kic...
dangl Embedded System
Transformer design formula (EXCEL format, suitable for power supplies below 150W)!!
1. Enter the output parameters of the switching power supply you want to design into the table. This table lists 4 output parameters, namely voltage output 1, current output 1; voltage output 2, curre...
potiancpu Power technology
Write the download program to MCU
Write the download program to MCU...
a7016 Embedded System
AD sampling question
I am using a 430 microcontroller to make a humidity sensor. The voltage signal is directly connected to the AD conversion pin through an op amp follower. After debugging, I found that the voltage samp...
rayqin Microcontroller MCU
Please introduce a minimal system
Remember!! It is the smallest, for example, it only receives the signal of a sensor, and then stores it, and can be read out on the computer later. Please introduce it~~~ Is there any? ? It seems that...
莫静好实 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2658  2032  2839  328  569  54  41  58  7  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号