EEWORLDEEWORLDEEWORLD

Part Number

Search

38-S126D4

Description
POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size232KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

38-S126D4 Overview

POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT

38-S126D4 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 305 V, COIL RELEASE VOLTAGE(AC): 60 V
body width46.2 mm
body height51.6 mm
Body length or diameter46.2 mm
Coil current (AC) maximum value0.03 A
Coil power5000 mW
Coil resistance15200 Ω
Maximum coil voltage (AC)452 V
Coil/Input Power TypeAC
Contact/Output Power TypeAC
Electrical life250000 Cycle(s)
Manufacturer's serial number38
Installation featuresPANEL MOUNT
physical size46.2mm X 46.2mm X 51.6mm
GuidelineUL
Relay actionMOMENTARY
Relay functionSPST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
Discovery and removal of dynamic embedded DLL Trojan virus
With the transition of MS operating system from Win98 to WinNT system (including 2k/xp), MS task manager has also been reborn and become more discerning (traditional Trojans can no longer hide their p...
action99 Embedded System
Communication Problems between PC and PLC
What is the hexadecimal frame instruction format when using the serial port debugging assistant to communicate with Mitsubishi Q series plc?...
shengming217 Embedded System
Electronic Design--Modularity
[i=s]This post was last edited by paulhyde on 2014-9-15 09:04[/i]Modularization A module is a typical general independent unit that can be combined into a system and has certain functions and interfac...
贝尔比 Electronics Design Contest
The wisdom of asking questions + C language books (transferred)
These are classic books. I hope they are useful to you.Specializing in STM8/32 QQ 940436962 [url=http://y-ec.taobao.com/]http://y-ec.taobao.com/[/url]...
fuqing5542 stm32/stm8
About vxworks testing
I want to test various interfaces under vxworks, such as the transmission rate of the serial port, etc. I want to have a quantitative result, but I don't know where to start. I hope someone with exper...
zs447150061 Real-time operating system RTOS
Common faults of compression card and hard disk recorder 1
Common failures of compression cards and DVRs When using a PC-type DVR, it is inevitable to encounter many sudden failures such as crashes. For newer machines that usually work normally, most of the c...
jek9528 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2478  2030  146  153  2174  50  41  3  4  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号