EEWORLDEEWORLDEEWORLD

Part Number

Search

2027-15-B19T1

Description
Surge Protection Circuit,
CategoryWireless rf/communication    Telecom circuit   
File Size161KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2027-15-B19T1 Overview

Surge Protection Circuit,

2027-15-B19T1 Parametric

Parameter NameAttribute value
MakerBourns
package instruction,
Reach Compliance Codeunknown
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
8 mm diameter, 6 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* versions available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Aircraft and military electronics
2027 Series - 2-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Model No.
2027-20
200 V
400 V
600 V
Characteristic
DC Sparkover ±15 %
(±20 % for Models 2027-07 & 2027-09) @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
(1)
2027-07
75 V
300 V
500 V
2027-09
90 V
300 V
500 V
2027-15
150 V
350 V
575 V
2027-23
230 V
450 V
675 V
2027-25
250 V
475 V
700 V
2027-30
300 V
550 V
800 V
2027-35
350 V
600 V
875 V
Model No.
2027-40
2027-42
400 V
420 V
650 V
925 V
675 V
950 V
2027-47
470 V
725 V
1000 V
2027-60
600 V
850 V
1100 V
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance .........................100 V (50 V for Models 2027-07 and 2027–09) ..................... > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................> 1A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage
(2)
......................135 V, (52 V for Models 2027-07 and 2027-09,
80 V for Model 2027-15) ........................................................ < 150 ms
Impulse Discharge Current .................25000 A, 8/20
μs
(3)
................................................................. 1 operation minimum
10000 A, 8/20
μs
.................................................................... > 10 operations
2500 A, 10/350
μs
.................................................................. 2 operations
500 A, 10/1000
μs
................................................................. > 400 operations
100 A, 10/1000
μs
or 10/700
μs
............................................. > 1000 operations
Alternating Discharge Current ............65 Arms, 11 cycles
(3)
.............................................................. 1 operation minimum
10 Arms, 1 s ........................................................................... > 10 operations
Operating Temperature....................................................................................................................... -55 to +125 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Moisture Sensitivity Level .................................................................................................................. 1
ESD Classification (HBM) .................................................................................................................. 6
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 27-xxxV.
• Sparkover limits ±20 % after life, IR >10
8
Ω
(-25 %, +30 % for Models 2027-07, 2027–09 and 2027–60).
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
(3)
Network applied.
DC Sparkover may exceed ±20 % after discharge, but will continue to protect without venting.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the
last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
Showing the process of WEBENCH design + low-cost automotive electronic module power supply design
I have heard of TI's WEBENCH tool for a long time and have tried to operate it several times. This time I just caught up with the event and learned it well. To be honest, the methods of selecting a co...
mengyun2801 Analogue and Mixed Signal
How to use IE controls on WinCE platform?
How to use IE controls on WinCE platform?...
bsfbaby713 Embedded System
[NXP Rapid IoT Review] + Rapid IoT App Running Error
[i=s]This post was last edited by bjemt on 2018-12-24 17:42[/i] I downloaded the Android phone App RAPID-IOT-1.1.5.apk from the NXP website and installed it on a Huawei M9 phone (Android 8). The App w...
bjemt RF/Wirelessly
vxworks transplant 2410. AXD made a mistake when debugging bootrom, hope everyone can help
AXD debug bootrom: Modify target\h\tool\gnu\defs.arm #CC_OPTIM_DRIVER = -O2 -fno-builtin -fvolatile #CC_OPTIM_NORMAL = -O2 -fno-builtinbbs #CC_OPTIM_TARGET = -O2 -fno-builtin -fvolatilebbs CC_OPTIM_DR...
cancan_919 Real-time operating system RTOS
This is the last filling. If you fill it again, I will charge you for the water.
Study on Loaded Normal Helical Antenna...
mutoudonggua RF/Wirelessly
White light LED welding technology
[hide]The welding requirements for blue and green LEDs are the same as those for white LEDs. Based on the general level of white LED welding, there are such basic requirements. The following points sh...
探路者 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1520  2606  95  952  1769  31  53  2  20  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号