Pressure Connections and Recommended Installation Torque
Name
Thread
Torque
G1/4A DIN 3852-E
External
20 Nm
7/16-20 UNF-2B
SAE J1926-1
Internal
20 Nm
7/16-20 UNF-2A
SAE J1926-2
External
20 Nm
G1/4A DIN 3852-A
External
20 Nm
Name
Thread
Torque
1/4-19 BSPT
R1/4 PER DIN EN 10226
External
20 Nm
1/4-18 NPTF
External
20 Nm
1/8-27 NPTF
Internal
20 Nm
Note: Recommended torque may varify according to material and specific application
GENERAL NOTES
* for more options see How to Order
2
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with
pressure port down.
3
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
4
Others on request
4
Unit shall be supplied by a power supply with double/reinforced insulation (SELV) and limited energy in accordance to UL/EN/IEC 61010-1 or LPS in accordance to UL/EN/IEC 60950-1 or
class 2 per UL1310/UL1585 (NEC or CEC). The power supply shall be approved for usage above 2000m if the pressure sensor is used in this enviroment.
For indoor and outdoor use, not exposed to direct sunlight.
P1A Sensor, 0 - 2.5 bar Gage, 4 - 20 mA Output, No External Seal Ring, G1/4
DIN 3852-E Pressure Connection, with 18mm, EN 175301-803-A003MS, 4 pole
Electrical Connector and Fluorocarbon FKM Internal Seal Ring
Family
P1A
P1A
06
G
1
A
01
A
D
Pressure Ranges
01
0 - 0.25 Bar
02
0 - 0.4 Bar
03
0 - 0.6 Bar
04
0 - 1 Bar
05
0 - 1.6 Bar
06
0 - 2.5 Bar
07
0 - 4 Bar
08
0 - 6 Bar
09
0 - 10 Bar
10
0 - 16 Bar
30
-1 - 0 Bar
31
-1 - 1 Bar
50
0 - 5 PSI
51
0 - 10 PSI
52
0 - 15 PSI
53
0 - 20 PSI
54
0 - 30 PSI
55
0 - 50 PSI
56
0 - 75 PSI
57
0 - 100 PSI
58
0 - 150 PSI
59
0 - 200 PSI
Reference
A:
Absolute
G:
Gage
Output
1:
4-20 mA
2:
0.5-4.5 VDC radiometric
3:
0-5 VDC
4:
0-10 VDC
External Seal Ring
A:
None
B:
Fluorocarbon FKM (Viton)
Only for pressure connection port option 1 lower temperature limited to -20°C
C:
Aluminium Washer G1/4
Only for pressure connection port option 4
D:
Copper Washer G1/4
Only for pressure connection port option 4
F:
Ethylene Propylene - EPDM
Only for pressure connection port option 1
Pressure Connection (Port)
01:
G 1/4A DIN 3852-E
05:
1/4-19 BSPT
02:
7/16-20UNF-2B (female) SAE J1926-1 (modified)
Is equivalent to 1/4-19PT and R1/4 per DIN EN 10226 5
With 45° cone and schrader
06:
1/4-18 NPTF
03:
7/16-20UNF-2A (male) SAE J1926-2 (modified)
11:
1/8-27 NPTF
With 45° cone
04:
G1/4A DIN 3852-A
Built-In Electrical Connection
A:
18mm, EN 175301-803-A003MS, 4 pole
D:
Packard Metri-Pack 150, 3 pole
Sensor delivered without mating connector
Sensor delivered without mating connector
C:
M12, 4 pole according to IEC 61076-2-101
Sensor delivered without mating connector
Internal Seal Ring
C:
Neoprene - CR
Operating Temp: - 30 to 120°C
D:
Fluorocarbon - FKM (VITON)
Operating Temp: - 20 to 120°C
E:
Fluorosilicone - FVMQ
Operating Temp: - 30 to 120°C
F:
Ethylene Propylene - EPDM
Operating Temp: - 30 to 120°C
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring conditions. Non-
compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual
commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our
products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under
no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other
electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of
Haha, when I was looking for information, I found an article I wrote before. Let's study it together:) I spent some time today to re-read the interruption. My previous understanding of interruption wa...
[i=s]This post was last edited by paulhyde on 2014-9-15 03:21[/i] Directly connected? Connected to an op amp? Connected to a transistor? How do you achieve low current?...
I have a question for you. When using F2808 SPI to communicate with EEPROM (AT25320AN), the read and write data are correct, which can be seen through the oscilloscope, but the data read back is not c...
This article introduces the process of PWM development of Beetle ESP32-C3 in Arduino IDE to realize the breathing light function - in fact, the sample code of DFROBOT official website is only modified...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
General LED lighting has a current limiting resistor in the driving circuit, and the power consumed by the resistor has nothing to do with the LED light emission. In order to improve efficiency, a...[Details]
Problems such as the depletion of natural resources, air pollution, traffic congestion, and rising fossil fuel prices have forced societies and individuals to seek alternative means of transportati...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
Motors, especially those with brushes, generate a lot of noise. This noise must be dealt with if the appliance is to meet the requirements of EMC standards. The means to solve EMC are nothing more ...[Details]
Introduction
As the country increases its efforts to control the atmospheric environment, motorcycle emission regulations will become stricter year by year, and motorcycles that do not meet the...[Details]
1 What is an LED floodlight?
LED downlights are also called spotlights, projection lamps, and spotlights. They are mainly used for architectural decorative lighting and commercial space lighti...[Details]
LED is the abbreviation of the English word. Its main meanings are: LED = Light Emitting Diode, a solid-state semiconductor device that can convert electrical energy into visible light. It can dire...[Details]
Against the backdrop of global warming, energy conservation and emission reduction have become a global hotspot and focus, which has also sounded the clarion call for the take-off of the LED lighti...[Details]
1 Introduction
At present, people have higher and higher requirements for the quality of life. When people are busy with work, soymilk machine is a new type of household beverage machine. It uses so...[Details]
1 Introduction
Washing machines are an indispensable household appliance in the home, and they are developing very fast. Fully automatic washing machines are favored by everyone because of their con...[Details]
When developing electronic products with processors, how to improve anti-interference ability and electromagnetic compatibility?
1. The following systems should pay special attention to anti-...[Details]