FUJITSU SEMICONDUCTOR
DATA SHEET
DS04-29101-5E
ASSP
Bidirectional Motor Driver
MB3763
s
DESCRIPTION
Fujitsu’s MB3763 Motor Driver with forward/reverse control capability, is used in applications such as the front-
loading mechanism in video tape, or the auto-reverse tape deck, driven by a TTL signal. The MB3763 has 150
mA drive units and braking capability with TTL control.
s
FEATURES
• Motor Drive Current: 150 mA maximum (DC)
300 mA maximum (t
ON
=
1 s, Duty
=
50
%)
• Wide Power Supply Voltage Range: 4V to 18V
• TTL-control capability
• Standby capability when input is off.
• Brake capability at motor stop mode.
• Built-in diode for surge absorption
• Package:
8-pin plastic DIP package (Suffix: –P)
8-pin plastic SOP package (Suffix: –PF)
s
PACKAGE
8-pin plastic DIP
8-pin plastic SOP
(DIP-8P-M01)
(FPT-8P-M01)
MB3763
s
PIN ASSIGNMENT
(TOP VIEW)
A-IN
GND
GND
B-IN
1
2
3
4
8
7
6
5
A-OUT
A-V
CC
B-V
CC
B-OUT
(DIP-8P-M01)
(FPT-8P-M01)
s
BLOCK DIAGRAM
A-V
CC
B-V
CC
Input
Logic
A-OUT
B-OUT
A-IN
GND
B-IN
2
MB3763
s
ABSOLUTE MAXIMUM RATINGS
(Ta = +25°C)
Parameter
Power supply voltage
Output current
Maximum output current
Power Dissipation
Operating temperature
Storage temperature
*1: t
ON
≤
1 s, Duty = 50%
*2: Ta
≤
60°C
*3: t
≤
5 ms
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
Symbol
V
CC
I
O
I
OMAX
*
3
P
D
T
C
Tstg
Rating
Min.
–20
–55
Max.
20
180 (330*
1
)
1.2
560*
2
+75
+125
Unit
V
mA
A
mW
°C
°C
s
RECOMMENDED OPERATING CONDITIONS
Parameter
Power supply voltage
Output current
Input high voltage
Input low voltage
*1: t
ON
≤
1 s, Duty = 50%
*2: When V
IH
≥
V
CC
, I
IH
≤
V
CC
×
0.2 mA
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
Symbol
V
CC
I
O
V
IH
*
2
V
IL
Value
Min.
4
0
2.4
0
Max.
18
150 (300*
1
)
V
CC
+ 0.3
0.4
Unit
V
mA
V
V
3
MB3763
s
ELECTRICAL CHARACTERISTICS
(V
CC
= 12 V, Ta = +25°C)
Parameter
Standby supply current
Symbol
I
CC0
I
CC1
Power supply current
I
CC2
I
CC3
Output high voltage
Output low voltage
Output saturation voltage
Input current
Input switching
prohibition time
V
OH
V
OL
V
SAT
I
IH
T
OFF
Condition
V
CC
= 18 V, V
IA
= V
IB
= 0 V
I
O
= 0 mA
I
O
= 150 mA
I
O
= 300 mA
I
O
= 0 mA, V
IA
= V
IB
= 2.4 V
I
O
= 150 mA
I
O
= 300 mA
I
O
= 150 mA
I
O
= 300 mA
I
O
= 150 mA
I
O
= 300 mA
V
IN
= 2.4 V
—
Value
Min.
—
—
—
—
—
11.0
10.8
—
—
—
—
—
10
Typ.
—
10
10
15
15
11.2
11.1
0.1
0.2
0.9
1.1
250
—
Max.
1.0
20
—
—
—
—
—
0.2
0.5
1.2
1.7
400
—
Unit
mA
mA
mA
mA
mA
V
V
V
V
V
V
µA
µs
4
MB3763
s
FUNCTIONAL DESCRIPTIONS
FORWARD/REVERSE MODE (MODE B& C)
In this mode, the transistor pairs Q2-Q3 and Q1-Q4 work alternatively, changing the output current direction.
When the mode B is selected, Q2 and Q3 are active and Q1 and Q4 are inactive. Therefore A-OUT is at low
level and B-OUT is at high level, with the current flowing from B-OUT to A-OUT through the motor. On the other
hand, when the mode C is selected, the current flows in the reverse direction.
BRAKE/STOP MODE (MODE A)
When the mode A is selected, Q1 and Q3 are inactive and Q2 and Q4 are active. A-OUT and B-OUT are stuck
at low-level; terminals of motor are shorted and the motor is forced to stop.
STANDBY MODE (MODE D)
In this mode, all transistors are inactive and the current through the motor does not flow. When the power supply
voltage is applied to A-V
CC
and B-V
CC
, the supply current is still less than or equal to 1 mA.
s
CONTROL MODE
Control Block Diagram
A-IN
B-IN
A-V
CC
Q1
A-OUT
Q2
Control
Logic
Q4
Q3
B-V
CC
B-OUT
GND
Mode
A
B
C
D
Notes: 1:
≥
2.4V
0:
≤
0.4V
Input mode
A-IN
1
1
0
0
B-IN
1
0
1
0
L
L
H
—
Output mode
A-OUT
B-OUT
L
H
L
—
Operation
short (Brake)
Forward
Reverse
Open (Standby)
5