Panel Mounted
Panel Mounted TVS L and C Circui tFilters
Ordering Information
Please state Part Number
e.g. if 1,000 pieces required of a 5 V working device, ordering would
be 1,000 of DLT2/L/1200n/LP/5/TVS.
Remember to include the working voltage in the Part Number.
Supplied without nut as standard.
DLT2/-/TVS
Case Dimensions
All dimensions in mm.
Washer
11.9 max.
Body
9.75
13 max.
4 min.
14.25 max.
6 min.
Materials
Body: Brass, silver finish.
Washer: Silver plated, beryllium-copper alloy.
Feedthrough terminations: Copper alloy, tin lead or silver finish.
1.75 x 1
Color Coding
1.0
Color Coding
Mounting Details
Thread
Chassis Thickness (max.)
Minimum Pitch
Nut A/F
Mounting Torque
M6 x 0.75 mm
2.25 mm
12 mm
8.2 mm
0.5 Nm
5.2 –0.1
6.2 –0.1
Mounting Details
Transient Voltage Performance
Parameter
Working Voltage (d.c.) V
WM
Breakdown Voltage
Clamping Voltage
Peak Current
Transient Energy
V
B
V
C
I
peak
E
tran
Test Conditions 5 V d.c.
<50 µA
1 mA d.c.
10 A 8/20 µs
8/20 µs
10/1000 µs
5.6
14 V d.c.
14
18 V d.c.
18
22.5 - 27
40
150
0.4
26 V d.c.
26
30.5 - 37.3
58
120
0.4
30 V d.c.
30
36 - 45
65
120
0.4
48 V d.c.
48
54.5 - 66.5
100
250
1.2
60 V d.c.
60
67 - 83
120
250
1.5
Unit
Volt (max.)
Volt (max.)
Volt (max.)
Amp (max.)
Joule (max.)
7.1 - 8.7 15.9 - 19.4
15.5
150
0.4
30
150
0.4
V
WM
- Maximum steady-state d.c. operating voltage the device can maintain and not exceed 50 µA leakage current.
V
B
V
C
- Voltage across the device measured at 1 mA d.c. current.
- Maximum peak voltage across the device measured at a specified pulse current and waveform.
I
peak
- Maximum peak current which may be applied with the specified waveform without device failure.
E
tran
- Maximum energy which may be dissipated with the specified waveform without device failure.
Characteristics
Part Number
DLT2/L/1200n/LP/
2
-/TVS
DLT2/C/1200n/LP/-/TVS
Min.
Current Rating
Capacitance
(A) for
(µF)
d.c. & 400 Hz a.c.
1.2
1.2
10
10
Insertion Loss (dB)
(50
Ω
system) (min.)
100 Mhz - 1 GHz
65
65
Color Code
1
(top end/thread end)
RED/RED
RED/WHITE
1
2
Value coding may replace color code.
Insert nominal working voltage (e.g. 5 or 14).
Marking: In addition to color code, transient protected device indicated by a black or
white dot on color coding to distinguish from standard DLT2/- range.
38
Oxley UK
Electronic Components Division
Email: sales@oxley.co.uk
Tel: +44 (0) 1229 582621
Beck Electronics
Email: sales@beck.co.uk
Tel: +44 (0) 1493 856282
Oxley Inc.
Email: sales@oxleyinc.com
Tel: (203) 488 1033
www.oxleygroup.com/emc
ODC:SMFIL:40489/3 - 1/00